Product details

Ultra pure water machineZYULUP floor standing
ultrapure watermachineDESCRIPTION:
The ZYULUP series high-end ultrapure water machine purifies urban tap water into high-purity laboratory water. It is a new generation of high-end ultrapure water machine developed and produced adhering to "humanized design, high positioning standards". Based on PLC fully automatic control and ARM series microcontroller and touch screen technology, it realizes graphic display of water production process, flow monitoring consumable replacement function, timed and quantitative water intake function, historical data query function and other technologies. The profession is suitable for high demand experimental projects such as scientific research and analysis.
Product Function Introduction:
Fully automatic control system
★ Four stage enhanced purification device for source water (PP+AC+softening+ultrafiltration)
★ The original Dow RO reverse osmosis membrane from the United States has a desalination rate of up to 98%
★ The first national pre-treatment system with fully automatic dual backwash function
★ Ultra purification column filled with Dow 450 polishing resin specifically designed for ultra pure water machines
★ Imported ultrafiltration membrane intercepts 5000 Dalton molecules
★ Imported dual wavelength ultraviolet digestion instrument
★ German Sartoris Terminal Microfiltration
★ Touchscreen and ARM series microcontroller microcomputer control, with self-control function
★ Intelligent TFT true color human-machine interface touch screen, graphic display of water production process, animated display to achieve "human-machine dialogue function"
The system has three water quality inspection display functions, including source water (PPM), pure water (μ s/cm), and ultrapure water monitoring (M Ω. cm), which reflect water quality data in real time
Pre treatment system, UF ultrafiltration system, RO reverse osmosis membrane automatic flushing cycle setting (flushing 1-99 seconds);
RO pure water online monitoring function and excessive emission setting function (5-99 μ s/cm), exceeding the set value will be discharged
UP ultra pure water online monitoring function and system circulation design function (30-180 seconds), to maintain standard water quality and extend the service life of consumables; UP ultra pure water over standard discharge function setting
■ Timer and quantitative water intake setting function (1-99 liters) clock setting (year, month, day, hour, and minute);
Fixed quality water intake setting function (0-18.25 M Ω. cm) Clock setting (year, month, day, hour, minute)
■ Flow monitoring consumables replacement cycle, prompting users to replace consumables technically;
Historical database query function
Previous water intake times/volumes (year/month/day/hour/minute/liter);
■ Water quality of each water intake (year/month/day/hour/minute/liter);
Accumulated total water production (liters);
Previous consumable alarm replacement records
System self-control protection function
■ Equipped with self checking and automatic protection functions for the startup system;
■ Water shortage protection alarm, automatic shutdown when full of water, low pressure protection and other functions;
■ Automatic shutdown protection for full water tank system
Basic technical parameters:
Inlet water source | Water pressure: 1-5 kg/cm2The water temperature is 10-45 ℃, and the total dissolved solids are, TDS<300ppm |
Working power supply | Voltage: AC220V/50HZ, Power: 30W-100W |
Host size | On stage: 420 * 600 * 620mm Floor standing: 580 * 680 * 1100mm |
Weight (KG) | On stage: 30-35KG Floor standing: 45-55KG |
noise | ≤40(dba) |
relative humidity | ≤ 85% RH, avoid corrosive gases |
Water tank equipped | On stage: standard 3.8G pure water tank Floor standing: standard 11G |
Terminal microfilter | 0.22 μ m microporous membrane filter (Sartorius, Germany) |
ultrapure watermachineTechnical indicators:
model | ZYULUP-A-5/10/20T (on stage) | ZYULUP-A-20/40/60/100L (floor standing) |
Water production capacity | 5/10/20 liters/hour | 20/40/60/100 liters/hour |
Outflow velocity | 1.5-1.8 liters/minute (when the water tank is storing water) | |
RO effluent water quality (μ s/cm) | Conductivity<5 μ s/cm (online monitoring), pollutant removal rate 99.5% | |
UP effluent quality (M Ω. cm) | Resistance 18-25M Ω· cm (online monitoring) Microparticles<1/ml Microorganisms<1cfu/ml Heavy metal ions<0.1ppb Total Organic Carbon (TOC) < 5ppb Soluble Silicon (calculated as SiO2) < 0.01mg/L Absorbance (254nm, 1cm optical path: ≤ 0.001 oxidizable substance [calculated as (0), ㎎/L]: ≤ zero point zero eight Cation content ≤ 0.1ppb (iron (Fe)<0.005, copper (Cu)<0.005, potassium (K)<0.02, aluminum (Al)<0.005, zinc (Zn)<0.02) Chromium (Cr) < 0.005 Sodium (Na) < 0.01) Anion content ≤ 0.1ppb (chlorine (Cl)<0.01ppb, Nitrite (NO)<0.02ppb, Nitrate (NO)<0.02ppb, Sulfate radical (SO)<0.01ppb) |
|
scope of application | 1. Ion Chromatography (lC)/Atomic Emission Spectroscopy (AES)/Gas/Liquid Chromatography Analysis (HPLC)/Atomic Absorption Spectroscopy (AA)/ 2. General quality analysis (MC)/electrophoresis/electrolysis/gel analysis/plasma emission spectrometry (lCP); 3. Experimental projects such as animal and plant cell culture, electrochemical research, gene research, in vitro fertilization, etc 4. Microelectronics/microanalysis/enzyme analysis/kinetics/immunodiagnosis/dissolution experiments 5. High demand experimental projects such as scientific research analysis/biochemical analysis |
ultrapure watermachineTechnical indicators:
model | ZYULUP-B-5/10/20T (on stage) | ZYULUP-B-20/40/60/100L (floor standing) |
Water production capacity | 5/10/20 liters/hour | 20/40/60/100 liters/hour |
Outflow velocity | 1.5-1.8 liters/minute (when the water tank is storing water) | |
RO effluent water quality (μ s/cm) | Conductivity<5 μ s/cm (online monitoring) pollutant removal rate 99.5% | |
UP effluent quality (M Ω. cm) | Electrical resistivity 18.25M Ω· cm (online monitoring) Heavy metal ions<0.1ppb, micro particles<1/ml, microorganisms<1cfu/ml Total organic carbon (TOC)<5ppb Heat source (endotoxin) ≤ 0.001EU/ml Soluble silicon (calculated as SiO2)<0.01mg/L absorbance (254nm, 1cm optical path: ≤ zero point zero zero one Oxidizable substances [calculated as (0), ㎎/L]: ≤ zero point zero eight Cation content ≤ 0.1ppb (iron (Fe)<0.005, copper (Cu)<0.005, potassium (K)<0.02, aluminum (Al)<0.005, zinc (Zn)<0.02) Chromium (Cr) < 0.005 Sodium (Na) < 0.01) Anion content ≤ 0.1ppb (chlorine (Cl)<0.01ppb, Nitrite (NO)<0.02ppb, Nitrate (NO)<0.02ppb, Sulfate radical (SO)<0.01ppb) |
|
scope of application | 1. Ion Chromatography (lC)/Atomic Emission Spectroscopy (AES)/Gas/Liquid Chromatography Analysis (HPLC)/Atomic Absorption Spectroscopy (AA)/ 2. General quality analysis (MC)/electrophoresis/electrolysis/gel analysis/plasma emission spectrometry (lCP); 3. Protein purification/amino acid analysis/toxicology research/animal and plant cell culture, molecular biology/trace metal/trace boron analysis/quantitative (PCR)/qualitative analysis 4. Electrophoresis/gel analysis/VOC/IVF/ICP/MC enzyme analysis/kinetics/immunodiagnosis/dissolution experiment 5. High demand experimental projects such as scientific research analysis/biochemical analysis |
ultrapure watermachineTechnical indicators:
model | ZYULUP-C-5/10/20T (on stage) | ZYULUP-C-20/40/60/100L (floor standing) |
Water production capacity | 5/10/20 liters/hour | 20/40/60/100 liters/hour |
Outflow velocity | 1.5-1.8 liters/minute (when the water tank is storing water) | |
RO effluent water quality (μ s/cm) | Conductivity<5 μ s/cm (online monitoring), pollutant removal rate 99.5% | |
UP effluent quality (M Ω. cm) | Resistance 18-25M Ω· cm (online monitoring) Microparticles<1/ml Microorganisms<1cfu/ml Heavy metal ions<0.1ppb Total Organic Carbon (TOC) < 5ppb Soluble Silicon (calculated as SiO2) < 0.01mg/L Absorbance (254nm, 1cm optical path: ≤ 0.001 oxidizable substance [calculated as (0), ㎎/L]: ≤ zero point zero eight Cation content ≤ 0.1ppb (iron (Fe)<0.005, copper (Cu)<0.005, potassium (K)<0.02, aluminum (Al)<0.005, zinc (Zn)<0.02) Chromium (Cr) < 0.005 Sodium (Na) < 0.01) Anion content ≤ 0.1ppb (chlorine (Cl)<0.01ppb, Nitrite (NO)<0.02ppb, Nitrate (NO)<0.02ppb, Sulfate radical (SO)<0.01ppb) |
|
scope of application | 1. Ion Chromatography (lC)/Atomic Emission Spectroscopy (AES)/Gas/Liquid Chromatography Analysis (HPLC)/Atomic Absorption Spectroscopy (AA)/ 2. General quality analysis (MC)/electrophoresis/electrolysis/gel analysis/plasma emission spectrometry (lCP); 3. Experimental projects such as animal and plant cell culture, electrochemical research, gene research, in vitro fertilization, etc 4. Microelectronics/microanalysis/enzyme analysis/kinetics/immunodiagnosis/dissolution experiments 5. High demand experimental projects such as scientific research analysis/biochemical analysis |
Ordering Notice:
■The water production capacity of this product refers to the rated water production capacity of the RO membrane at a water temperature of 25 ℃. For every 1 ℃ decrease in water temperature, the water production capacity of the RO membrane decreases by about 3%. When the water temperature is below 5 ℃, the RO membrane will stop producing water. When selecting and ordering, users must consider the factor of the decrease in winter water temperature in their region;
■In areas with poor source water quality (TDS>200ppm), the conductivity of RO pure water may decrease to over 10 μ s/cm; For users with high water quality requirements, it is recommended to choose UPR (dual stage reverse osmosis) or pre soft water system (multi-media filter+activated carbon filter+water softener).