Overview: ZRN-WZP-WZSeries threaded connection pt100temperature sensorIt consists of three parts: junction box, fixed thread, and protective tube. The product can be widely used to measure temperature, liquid temperature, oil temperature, and surface temperature of objects
As a temperature sensor, the working principle of platinum resistance element is that the resistance value of platinum resistance wire changes with the temperature under the action of temperature. The relationship between temperature and resistance is close to a linear relationship, with minimal deviation that can be ignored over time, and the electrical performance is stable Please refer to the article "Temperature Sensor Installation Method" for the insertion depth and installation depth of temperature sensors, thermocouples, and thermal resistors.
Model
|
Technical parameters
|
Structural schematic diagram
|
ZRN-WZP-WZ
|
1. Platinum resistors: Pt100, Pt500, Pt1000
Temperature measurement range: (-80~500) ℃
2. Common accuracy levels:
Grade A: ± (0.15+0.002 | t |) ℃
Grade B: ± (0.30+0.005 | t |) ℃
|T | --- Absolute value of measured temperature
3. Unless otherwise specified, C=L+150(Cold end), can also be specified
4. Under normal pressure, for working conditions with pressure, please indicate the pressure level
|
There is a cold end but no cold end
|
ChooseTypeTable
|
ZRN-WZP-WZ
|
|
Platinum thermistor model
|
|
B□
|
1=Pt100 5=Pt500 10=Pt1000
|
sensor type
|
|
T□
|
1=-50~80 2=0~100 2=-50~200 3=-50~250 specified
|
Temperature range (℃)
|
|
P□
|
B=Grade B A=Designated Grade A
|
sensor accuracy
|
|
Nopening
|
0=none 150=150 (standard supply product)
appoint
|
Is there a cold end
|
C□
|
100=100 250=250
350=350 600=600 specified
|
Total length of protective tube (mm)
|
D□
|
4=4 8=8 12=12 16=16 specified
|
Protection tube diameter
|
M□
|
5=M5×0.8 8=M8×1
10=M10×1 12=M12×1.5
16=M16×1.5
appoint
|
thread specification
|
S□
|
1=SUS3214=SUS304 6=SUS316appoint
|
Material of protective tube
|
|
E□
|
2=Two wires 3=Three wires 4=Four wires
|
Lead wire system
|
|
Gopening
|
1=Anti spray type
2=Waterproof specification
|
Junction Box Type
|
|
Z□
|
0=None, can be left blank
2=Armored type
3=Anti corrosion treatment
appoint
|
special requirements
|
notes:For user specified parameter requirements, simply indicate them with numbers or text.
Example of Selection:WZP-A - B1- T3- PA - N0/C350/D4/M10/S4- E3- G2
explain:PT100, temperature measurement range -50~200 ℃, accuracy grade A, three wire system, protective tube diameter 4mm, length 350mm, waterproof junction box
|
The WZ series industrial thermistor is commonly used as a temperature measurement sensor and is typically paired with temperature transmitters, regulators, and display instruments to form a process control system To directly measure or control the temperature of liquid, vapor, gas media, and solid surfaces within the range of -200 ℃ to -500 ℃ in various production processes Thermistor measures temperature by utilizing the characteristic that the resistance of a substance changes with temperature When there is a temperature gradient present in the measured medium Temperature is the average temperature in the medium where the temperature sensing element is located Although there are significant differences in the appearance of various thermal resistors, their basic structures are generally similar, including temperature sensing elements, insulation sleeves, protective tubes, and junction boxes Composition
Characteristics ·Pressure spring type temperature sensing element with good anti vibration performance; ·High temperature measurement accuracy; ·High mechanical strength and good pressure resistance; ·Imported thin film resistor components with reliable and stable performance.
Working principle Thermistor measures temperature by utilizing the characteristic that the resistance of a substance changes with temperature. When the resistance changes, the working instrument displays The temperature value corresponding to the resistance value. Main technical parameters Product execution standards IEC584 IEC1515 GB/T16839-1997 JB/T5582-91 Room temperature insulation resistance The thermal resistance is tested at an ambient temperature of 15-35 ° C, relative humidity not exceeding 80%, and a test voltage of 10-100V (DC) between the electrode and the outer sheath Resistance>100M Ω. Measure temperature and tolerance
|
|