Jiangsu Zhongneng Instrument Technology Co., Ltd
Home>Products>ZN1151/3351GP pressure transmitter
ZN1151/3351GP pressure transmitter
Pressure transmitters are used to measure the liquid level, density, and pressure of liquids, gases, or vapors, and then convert them into 4-20mA DC s
Product details

pressure transmitterUsed to measure the liquid level, density, and pressure of liquids, gases, or vapors, and then convert them into 4-20mA DC signal output. ZN1151/3351GPIntelligent pressure transmitterIt can communicate with the HART handheld device for setting, monitoring, or forming an on-site monitoring system with the upper computer.
ZN1151/3351GP on-site adjustable intelligentpressure transmitterThis is a new product developed by our company based on on-site requirements. It can be operated without a manual controller and can be adjusted and configured on-site through button pressing.
1. Performance specifications
(Zero benchmark calibration range, under reference conditions, filled with silicone oil, 316 L stainless steel isolation diaphragm.)

1.1. Reference accuracy
1.1.1. Digital and intelligent: ± 0.1% calibration range
1.1.2. Simulation, linear: ± 0.2% calibration range
1.2. stability
1.2.1. Digital and intelligent: 6 months, ± 0.1% URL
1.2.2. Simulation, linear: 6 months, ± 0.2% URL
1.3. Environmental temperature impact
1.3.1. Numbers and Intelligence:
Zero point error: ± 0.2% URL/56 ℃
Overall error: ± (0.2% URL+0.18% calibration range)/56 ℃
1.3.2. Simulation, Linear
Zero point error: ± 0.5% URL/56 ℃
Overall error: ± (0.5% URL+0.5% calibration range)/56 ℃
1.4. vibration effect
In any axial direction, the vibration effect at 200Hz is ± 0.05% URL/g
1.5. Power supply impact
Less than ± 0.005% output range/volt.
1.6. Load impact:
There is no load impact unless there is a change in the power supply voltage.
1.7. Electromagnetic interference/radio frequency interference (EMI/RFI impact)
When the field strength reaches 30V/M from 20 to 1000MHz, the output drift is less than ± 0.1% of the range.

1.8. Installation location impact
The zero drift is at most ± 0.25kPa. All zero drift
All can be corrected; Has no impact on the measurement range.
2. Functional specifications
2.1. Measurement range: 0-0.125-41370KPa
2.2. Zero point and range
2.2.1. Digital and intelligent
It can be adjusted using the local range and zero buttons, or remotely using a HART controller
2.2.2. Simulation, linear
Range and zero point continuously adjustable
2.3. Zero point positive and negative transfer
When zero point negative shift occurs, the lower limit of the range must be greater than or equal to - URL; When zero point is shifted forward, the upper limit of the range must be less than or equal to+URL. The verification range must be greater than or equal to the minimum range.
2.4. output
Digital and intelligent:
4-20mA DC, users can choose linear or square root output. The digital process variables are superimposed on a 4-20mA signal and can be used by upper level computers using the HART protocol
Simulation, linear:
4-20mA DC, linear with process pressure.


◆ Selection method

ZN1151/3351GP

pressure transmitter

code

Range of measurementKPa

2

0-0.1251.5

3

0-1.37.5

4

0-6.237.4

5

0-31.1186.8

6

0-117690

7

0-3452068

8

0-11706890

9

0-345020680

0

0-689041370

code

output

E

4-20mA

S

intelligent

code

Structural materials

Flanges and fittings

exhaust/Drain valve

Isolation Diaphragm

Fill with liquid

22

316stainless steel

316stainless steel

316stainless steel

silicone oil

23

316stainless steel

316stainless steel

Hastelloy alloyC

24

316stainless steel

316stainless steel

Monel

25

316stainless steel

316stainless steel

tantalum

33

Hastelloy alloyC

Hastelloy alloyC

Hastelloy alloyC

35

Hastelloy alloyC

Hastelloy alloyC

tantalum

44

Monel

Monel

Monel

code

option

M1

0-100%Linear indicator table

M2

LED display table

M3

LCD display table

B1

Pipe bending bracket

B2

Board mounted bending bracket

B3

Pipe mounted flat bracket

D1

The side relief valve is located at the upper part of the pressure chamber

D2

The side relief valve is located at the lower part of the pressure chamber

No note

1/2NPTCone pipe threaded joint

C2

T-shaped threaded jointM20×1.5, with rear weldingФ14Spherical cone connector of pressure pipe

d

Explosion proof typedⅡBT4

i

Intrinsically safe typeiaⅡCT6

s

Stainless steel three valve group

Electromagnetic flowmeter K-type thermocouple thermal resistance bimetallic thermometer pressure transmitter flow transmitterIntelligent differential pressure transmitter

Online inquiry
  • Contacts
  • Company
  • Telephone
  • Email
  • WeChat
  • Verification Code
  • Message Content

Successful operation!

Successful operation!

Successful operation!