Xi'an Zhuofan Petroleum Instrument Co., Ltd
Home>Products>ZFY-3100A Oil Gas Chromatography Analyzer
Firm Information
  • Transaction Level
    VIP member
  • Contact
  • Phone
    13679229956/13384989114
  • Address
    No. 132 Caolin Road, Baqiao District, Xi'an City
Contact Now
ZFY-3100A Oil Gas Chromatography Analyzer
★ Instrument Overview:
Product details

Instrument Overview:

gas chromatographWidely used for routine and trace analysis in petrochemical, gas, fine chemical, environmental monitoring, biochemistry, organic chemistry, food processing, clinical applications of Chinese and Western pharmaceuticals, health quarantine, etc. This instrument can be used to determine oxygen-containing compounds, benzene, toluene, alcohols, and ethers in gasoline.

Applicable standards:

SH/T0663SH/T0693-2000class

Main performance characteristics and parameters:

Adopting a large screen LCD display;

Equipped with self diagnosis, data power-off protection0Protection against overheating and other functions;
Microcomputer controlFIDThe detector automatically ignites and has a stopwatch timing function;

The main control circuit adopts advanced microprocessors to make data storage more reliable; .
Intelligent dual back door technology, eight step programmed heating, suitable for the analysis of complex samples with wide boiling points.

Large volume column box, capable of simultaneously installing four chromatography columns and three types of detectors;
Flexible packed column and capillary column systems,Can connect capillary columns of different diameters.

Temperature control accuracy: room temperature+5℃~420℃, accuracy±0.1℃.
Column temperature box volume:280mm
×280mm×250mm.
Program heating order: eight orders.
Program heating rate:1℃-50℃.
Constant temperature holding time for each stage:0300min1minIncremental).
Automatic rear door design ensures rapid cooling.
A high-power, low-noise rotating fan ensures temperature uniformity.

Hydrogen flame ionization detector(FID
● Detection limit:Mt5×10-12g/s(Hexadecane);
Noise: ≤2×10-14A0.02mv
Drift: ≤1.5×10-13A/30min0.15mv/0.5h
● Linear range: ≥107

Maximum operating temperature: ≤450
Thermal conductivity detector(TCD
Sensitivity:S5000mV.ml/mg(HEXADECANE)

Noise: ≤20μV
Baseline drift: ≤150μv/30min

Component category

Main component names

alcohols

methanol

ethanol

isopropanol

Tert butanol

n-PrOH

Sec-butyl alcohol

Isobutanol

Tert-amyl alcohol

Zhengding alcohol

Ether class

mtbe

diisopropyl ether

TAME

aromatic hydrocarbon

benzene

toluene

C8aromatic hydrocarbon

≥C9aromatic hydrocarbon

total aromatics

Online inquiry
  • Contacts
  • Company
  • Telephone
  • Email
  • WeChat
  • Verification Code
  • Message Content

Successful operation!

Successful operation!

Successful operation!