Scope of application: Mainly used to determine the calorific value of coal, fuel oil, biomass fuel, petroleum, solid waste, and other combustibles
Product details

Scope of application:

Mainly used for measuringcoalfuel oilBiomass fuelpetroleumSolid wasteThe calorific value of other combustibles.

meet the standard
GB/T213-2008 "Method for determination of calorific value of coal"
GB/T384-1981 "Determination of Calorific Value of Petroleum Products"
GB/T30727-2014 "Method for determination of calorific value of solid biomass fuels"
JC/T1005-2006 "Method for determination of calorific value of cement black raw materials"
ASTM D5865-2007 Standard Test Method for Gross Calorific Value of Coal and Coke

Performance characteristics:

1Controlled by a computer, using automation software, and capable of achieving dual control or multi control for one machine.

2Automatic water injection, automatic drainage, no need to adjust water temperature, just install an oxygen bomb into the cylinder, and the instrument can automatically complete all testing work.

3Adopting serial communication technology, integrating system control and data management, with good compatibility, using scientific and effective algorithms to automatically print high and low heat generation.

4High data accuracy, stable system, and low failure rate, can be continuousMake samples within 24 hours.

5CalorimeterThe middle cylinder adopts vacuum technology and is not affected by external temperature.

6The mixing motor has been improved, resulting in higher stability of the instrument.

7It can achieve remote data transmission and can be used for office automation.

Technical Specifications:

1. Temperature measurement range: 0 ℃~65 ℃

2. Temperature resolution: 0.0001 ℃

3. Accuracy: ≤ 0.1%

4. Sample weight: 0.9-1.1g

5. Heat capacity: approximately 10500J/K

6. Testing time: 15 minutes

7. Ignition voltage: 20V

8. Power: < 500W

9. Working voltage: 220V±10%

Online inquiry