BY-XJ-4000 12 input yellow screen paperless recorder, capable of inputting signals such as standard current, standard voltage, frequency, millivolts, thermocouples, thermal resistance, etc. It has functions such as sensor isolation distribution output, relay alarm output, transmission output, flow accumulation, temperature and pressure compensation, historical data transfer and storage, printing, and remote communication.
Functional Features
5.1-inch 160 × 128 dot matrix graphic LCD display with LED backlight.
The screen contrast can be freely adjusted;
High speed, high-performance 32-bit ARM microprocessor, with a screen response time of less than 0.2 seconds, capable of detecting, recording, displaying, and alerting 12 signals simultaneously;
Adopting new large-scale integrated circuits and carefully designed components from internationally renowned factories;
Large capacity FLASH flash memory chips store historical data and never lose data in case of power failure;
Fully isolated input, capable of inputting multiple signals without the need for jumpers, can be configured through software;
The quantity display has a wide range of numerical values and can display 5-digit values: -9999 to 19999;
Support vacuum Scientific notation display;
Chinese Laidan configuration, display project tag number, and engineering unit. The software password lock ensures user configuration security.
Alarm display, indicating the lower and lower limits, lower and upper limits, and upper and upper limits of each channel alarm. Can record the last 15 alarm messages;
Use USB 2.0 interface to transfer and backup historical records, supporting 256MB, 512MB, and 1GB USB drives;
Standard serial communication interfaces: RS-485 and RS-232C;
Supports standard Modbus RTU communication protocol, in addition to our company's ScanX data management software, it also supports popular professional configuration software such as iFIX, Kingview, MCGS, PCAuto, etc., without the need for dedicated drivers;
Can be connected to an external micro printer, supporting manual printing and timed automatic printing, meeting the needs of users for on-site printing;
Integrated hardware real-time clock, the clock can run accurately even in the event of power failure;
The new switch power supply operates normally within the range of 85VAC to 265VAC;
Provide transmitter+24VDC isolated power distribution.
The compensation model is rich and can compensate for various media such as liquids, general gases, steam, and natural gas.
The small flow supplement metering function compensates according to the set value after the instrument loses power.
Provide 8-hour shift reports, 12 hour shift reports, daily reports, and monthly reports. The settlement time can be freely set.
When the temperature sensor or pressure sensor malfunctions, it will automatically switch to the set temperature and pressure to calculate the compensation amount.
It has a power-off recording function, which records the time of instrument power on and power-off, displays the cumulative power-off time, and prevents users from stealing steam during power outages.
The all aluminum sealed shell and internal shielding plate ensure the normal operation of the instrument in harsh environments.
Specification
monitor5.1-inch 160 × 128 dot matrix TFT graphic LCD display screen, LED backlight, wide viewing angle
Basic error:±0.2%F·S
Fully isolated input: 1-12 channel signal input, fully isolated between channels, isolation voltage>400V
Enter specifications:
BY-XJ-7000 series input range meter | ||||||
Input Type |
Range of measurement |
Input Type |
Range (℃) |
|||
Type II: 0-10mA, 0-5V |
-9999~19999 |
heat electricity image |
B |
500~1800 |
||
Type III: 4-20mA, 1-5V |
-9999~19999 |
S |
0~1600 |
|||
20mA |
0~20 mV |
K |
0~1300 |
|||
100mV |
0~100 mV |
E |
0~1000 |
|||
Frequency Fr |
0~10KHz |
J |
0~1000 |
|||
heat electricity Resistance |
Cu50 |
-50~140℃ |
R |
0~1600 |
||
Cu53 |
-50~140℃ |
N |
0~1300 |
|||
BA1 |
-100~600℃ |
T |
0~380 |
|||
BA2 |
-100~600℃ |
WRe5-26 |
0~1800 |
|||
Pt100 |
-200~650℃ |
radiation pyrometer |
F1 |
700~2000 |
||
Resistance 0~350 Ω |
-9999~19999 |
F2 |
700~2000 |
|||
Output specifications:
Distribution: 4 sets of 24VDC output, output current of 60 mA/set, 12 configurable relay contact outputs, contact capacity of 3A, 250VAC (resistive load) default to normally open contacts. *Multiple 4-channel analog output (transmission output or PID output), 4-20mADC, load resistance<600 Ω
Compensation operation:
Steam: According to the steam density table, query the steam density and compensate for the mass flow rate of steam.
Pressure range 0.1-22MPa, temperature range 0-600 ℃
Water: According to the water density table, query the water density and compensate for the mass flow rate of water
Temperature range 0-150 ℃
Cumulative range:0~9999999999
Communication and printingCommunication interface: RS232C or RS485
Baud rates: 1200, 2400, 1800, 9600, 19200, 38400, 57600
Printing interface: RS232C directly connected to serial micro printer
recording time:
Record interval: 1, 2, 5, 10, 15, 30, 60, 120, 240 seconds optional.
Record length: 72 hours/pen (record interval of 1 second) to 720 days/pen (record interval of 4 minutes)
Record Interval |
1 second |
2 seconds |
5 seconds |
10 seconds |
15 seconds |
30 seconds |
1 point |
2 points |
4 points |
Record length |
72 hours |
6 days |
15 Days |
30 days |
45 days |
90 days |
180 days |
360 days |
720 days |
Data backup and transfer256MB~1G USB drive optional
Cold end compensation error of thermocouple:± 1℃
power-off protectionBuilt in FLASH memory, protects parameters and historical data, and can be saved after power failure. Integrated hardware clock that can operate accurately even after power failure.
power supplySwitching power supply 85VAC~265VAC, 50Hz ± 5%, power consumption<59W
ambient temperature:0-50℃
ambient humidity:0-85%RH