YMCZ-01 smart socket is a socket that can be connected to the Internet through LoRaWAN wireless network to realize network control of electrical power supply. This product can directly and accurately measure positive active energy, and has functions such as button opening and closing, and power limiting. At the same time, it also has wireless communication function, which can realize remote meter reading and meter setting. The communication protocol follows the DL/T645-2007 and DL/T645-1997 standards. Its performance indicators comply with the GB/T 17215.321-2008 standard. This product is manufactured using internationally advanced specialized ultra large scale integrated circuits and SMT technology. The key components are all low-power, long-life devices from internationally renowned brands. The overall design adopts multiple anti-interference technologies to ensure the reliability and service life of the product.
Working principle diagram
2.2Working principle explanation YMCZ-01Smart socketIt consists of two main functions: one is the energy metering part, and the other is the microprocessor control part. The energy metering part uses a shunt multiplication circuit to sample and convert current and voltage signals, and the microprocessor performs energy metering. The microprocessor transmits data to the load switch to achieve power control function Specification parameters
4. Main functions4.1 Electricity meteringHaving positive active energy metering functionReverse energy positive meter. 4.2Power limit Smart sockets can be set up according to requirementsOutput powerlimitsEnsure electrical safety. When the load power exceeds the set power value, it can automatically trip,Test in 2 minutesLoad, power can be automatically restored after the load is normal. This product'sThe maximum output power can reach2500W. 4.3key①When pressing the button,The button controls the closing of the relay, and the closing time is1 minute. ②Pressing the button can trigger data reporting. 4.4displayAdopting high brightness and long lifespanLEDAs an indicator light to display the status of the smart socket ① Pulse indicator light: red, presentworkFlashing when outputting electrical energy. ②closeBrake indicator light:greenWhen the relaycloseWhen the gate is closed, the indicator light is on. 4.5communicationSmart sockethaveLoRaWANcommunication functionIt can achieve wireless communication to remotely transmit measurement data and control sockets. 5. Product installation5.1 InstallationSmart socketIt should be installed for indoor use.Smart socket backThere are two mounting holes on the terminal block that can be fixed with screws; installSmart socketThe bottom plate should be placed on a sturdy and fire-resistant wall, and it is recommended to install it at a height of1.2About meters.Smart socketThe dimensions are shown in the following figure:
5.2 WiringSmart socketThe wiring diagram on the terminal box should be followedFor wiring, it is best to use copper wire or copper wire connectors for introduction.
6. Transportation and StorageSmart socketTransportation should not be subjected to severe impacts and should be based onGB/T13384General Technical Conditions for Packaging of Mechanical and Electrical ProductsRegulations on transportation and storage. Inventory and storage should be placed on racks in their original packaging conditions, with a stacking height of no more than five layers. The storage area should be clean, and the ambient temperature should be-40-70 ℃, relative humidity not exceeding 85%, and no harmful substances that can cause corrosion in the air. 7. Warranty periodSmart socketFrom the date of manufacture, within 18 months, if the user complies with the requirements specified in the manual, uses it correctly, andProduct appearanceUnder still intact conditions, if discoveredSmart socketIf it does not meet the requirements stipulated in the technical regulations, the company will provide free repair or replacement. Product damage caused by the following reasons is not within the scope of replacement: 1)Damage caused by not operating according to the instructions; 2)Damage caused by unauthorized disassembly or repair by users, and other human caused damages. 8. Precautions8.1 This product has been inspected and approved before leaving the factory. Please follow the wiring diagram when using it (the power supply inlet and outlet cannot be reversed))All terminals must be properly connected and tightened. 8.2Smart socketInstalled in a ventilated and dry indoor area(cannot be used for bathrooms, etc.), installationSmart socketThe bottom plate should be fixed on a sturdy, fire-resistant, and vibration resistant wall.Smart socketIt should be installed vertically. 8.3Smart socketThe working environment should have lightning protection measures. |