KLD-C NO2-N is a fully automatic online analyzer developed by Xiamen Jilongde Environmental Engineering Co., Ltd. The use of imported CPU motherboards, high-precision signal processors, and a simple and stable waterway system effectively reduces signal fluctuations, ensuring data accuracy and stability; The electrical part and water pipeline are completely isolated to ensure that the analyzer can operate stably for a long time. Suitable for various water qualities such as river water, surface water, and industrial wastewater.
characteristic:
1. Stable and reliable
According to the requirements of industrial and environmental online, the electrical part and water pipeline are completely isolated to ensure that the analyzer can operate stably for a long time.
2. Quantitative accuracy
Controlled by the CPU motherboard, the solenoid valve is used for quantitative dosing, with accurate dosing, simple and stable structure, and long service life.
3. Easy to install
The analyzer has passed a series of tests before leaving the factory. During installation, simply connect the reagent tube, sample tube, pure water tube, waste liquid tube, and power cord, and set the parameters to operate.
4. Automatic correction
The analyzer performs calibration based on the calibration time and calibration type set by the user. If the obtained result exceeds the set limit, the original calibration parameters will not be replaced and an alarm signal will be output.
5. Automatic monitoring
Users can freely set the measurement time interval. The analyzer remains in standby mode between two measurements.
advantage:
Adopting an automatic monitoring system, simple maintenance, automatic alarm in case of abnormalities, low maintenance volume, and low operating costs
Standard 4-20mA analog signal output, standard RS232, RS485 digital signal output, standard MODBUS protocol
Adopting a brand new signal processor to reduce signal fluctuations and ensure data accuracy and stability
Adopting high-precision peristaltic pump design to extend the service life of the pump tube
After power failure, it has the function of automatically starting when there is an incoming call
Can be connected to a local or remote PC for remote control
Low drug consumption and short preparation time
Equipped with automatic diagnostic function, it can identify whether there is a shortage of medication and issue an alarm
Capable of outputting instrument operation signals
Store 3000 sets of data, available for USB download of analysis data and operation record data
No special professionals are needed, only simple training is needed to operate
Can control the operation of the water pump and freely set the sampling time of the water pump
Equipped with security management function, the device automatically records and stores all control operations in a read-only manner
Having second level operational management privileges, system administrators can perform all system operations, while general operators only perform routine maintenance and operations
Optional configuration:
Dual channel mode
Realize online monitoring of one instrument and two discharge ports
Pharmaceutical refrigeration box
Extend the service life of medication and reduce the frequency of medication replacement
Alarm function
Pure water low limit alarm and waste liquid high limit alarm function
Automatic dilution function
Automatic dilution of high concentration samples
Mini printer
Print data after measurement is completed
Analysis principle:
After filtering, the sample is pumped into the reactor, and sulfonamide and naphthylethylenediamine dihydrochloride are added. After thorough mixing and reaction, the analyzer measures the ABS value of the red substance generated by the reaction at a specific wavelength, and calculates the concentration of the sample based on the calibration data stored in the analyzer.
Instrument technical parameters:
measuring principle |
1-Naphthalene ethylenediamine dihydrochloride/p-aminobenzenesulfonamide colorimetric method |
Operation management |
Equipped with safety management and secondary operation management functions |
measurement type |
Manual or set interval automatic analysis |
Measurement Interval |
It can be freely programmed according to the actual situation, and can also be controlled by RS232 |
Time |
8 minutes |
measuring range |
0.01~5/10/20/50/100mg/L (range can be ordered according to requirements) |
Correction type |
Manual or set interval automatic calibration |
Precision |
≤5% |
Accuracy |
±5% |
zero drift |
5%F.S |
Span Drift |
5%F.S |
signal output |
Standard 4-20mA analog output, standard RS232/RS485 digital output, MODBUS protocol |
Alarm |
Concentration high limit alarm, low limit alarm, medication shortage alarm, calibration error alarm (standard) Pure water low limit alarm, waste liquid high limit alarm (optional) |
Sample and waste liquid transportation |
No pressure required |
Storage temperature of pharmaceuticals |
10-30℃ |
Medication replacement cycle |
3-4 weeks, depending on the ambient temperature |
ambient temperature |
5-40℃ |
protection grade |
IP55 |
mean time between failures |
>720h/time |
Display |
Color touch screen (optional languages: Simplified Chinese, Traditional Chinese, English) |
Power supply |
Power supply AC 220V ± 10%; Power 90W |
Weight |
About 60kg (excluding medication) |
Size |
1600x500x400mm (H x W x D) (including base height) |