XSL Intelligent Patrol Detection Alarm Device
summary:
XSL intelligent patrol detection alarm instrumentInput 5-96 channels, thermal resistance, thermocouple, current
Voltage input;Basic error±0.2%F·S, Display range -1999~9999, measuring speed per
Channel 0.2 seconds;Each channel independently sets the signal type, range, and alarm value;Each channel is unique
The calibration function of the system effectively reduces sensor errors and improves the measurement and control accuracy of the system;
Unused channels can be closed at will, and channels that have been closed will no longer display alarms or prints;
Level 2 parameters, the second level configuration parameters are password controlled and have parameter copying function, which can be quickly accessed
Setting parameters greatly reduces the workload of parameter setting;Unique and practical alarm function
Technical indicators:
input |
Number of channels: 5~80 channels Thermal resistance: Pt100, Cu100, Cu50, BA1, BA2, G53 full range measurement, display resolution of 0.1 ℃, with wire breakage recognition function Thermocouple: Full range measurement of K, S, R, B, N, E, J, T, etc. (including negative temperature), display resolution of 1 ℃ or 0.1 ℃, selected by parameters. Has wire breakage recognition function DC current: 4mA~20mA, 0mA~10mA, 0mA~20mA, display range -1999~9999, freely set range and decimal point position DC voltage: 1V~5V, 0V~5V, display range -1999~9999, freely set range and decimal point position Thermal resistance input wire resistance: within 20 Ω Thermocouple input wire resistance: within 100 Ω |
Precision adopts 16 bit A/D converter |
Measurement accuracy: ± 0.2% F·S display resolution: 1/10000 |
Thermocouple cold junction compensation accuracy: ± 0.2 ℃, range 0 ℃~60 ℃ | |
speed |
The fastest is 100ms per channel, and Parameter related |
display |
2-digit LED channel number display, 4-digit LED measurement value display, alarm status indicator light and communication indicator light for each channel |
call the police 3 alarm methods |
2-point (expandable to 4-point) common alarm relay output |
Output relay contact capacity: 250V AC, 2A (resistive load) | |
Connect XSLCU multi-point control unit to achieve alarm output for each channel | |
communication |
RS 232 or RS 485 interface, photoelectric isolation instrument address 0~99 can set communication rates of 2400, 4800, 9600, 19200. By selecting the matching test software through setting, configuration software and application software are provided Technical Support |
Built in hardware clock, power outage does not affect timekeeping, automatically adjusts leap years, major and minor months. There are three printing startup modes: manual, manual+timed, and manual+timed+alarm, which can be selected through settings Print content: time, alarm status, measured values, engineering units
|
|
power supply |
V0:160V AC~260V AC,50Hz |
V1:20V DC~28V DC | |
environment |
Temperature: 0 ℃~50 ℃ |
Humidity: less than 90% R·H |