Shanghai Baoying Optoelectronics Technology Co., Ltd
Home>Products>Volatile Organic Compounds Online Alarm System
Firm Information
  • Transaction Level
    VIP member
  • Contact
  • Phone
  • Address
    Building 5, No. 69, Lane 1159, Kangqiao East Road, Pudong New Area, Shanghai
Contact Now
Volatile Organic Compounds Online Alarm System
This device is mainly used for real-time monitoring of VOCs gases within the factory boundary. It uses a highly sensitive and applicable PID (photoion
Product details

  
productpurpose

Used for unorganized emission testing; Unorganized emissions refer to the irregular discharge of waste gas pollutants generated during the production process and not through exhaust pipes. The sampling location is the main production workshop and factory boundary.

System Characteristics

1Fully functional and can be monitoredVOCsIt has five meteorological parameters and can be extended to other gases;

2Built in usability10000An hour's worth of imported air pump and automatic control of its flow rate1.0L/Min

3Adopting imported technologyPIDDetector, with monitoring accuracy up toppbGrade;

4External air pre-treatment device can effectively filter dust and water vapor;

5Modular design reduces operation and maintenance costs;

6Equipped with a large capacity high-performance battery, it can ensure operation after power failure48More than hours;

7Optional online factory interfaceVOCsDetection system;

8The shell has a temperature self regulating function, equipped with a heat shield, and effectively controls the temperature of the box through nano thermal insulation spraying materials and internal circulation system.

Serial Number

Gas name

detection range

check the accuracy

resolution

1

Cl2

0–5 ppm

< 5%

50ppb

2

HCl

0–30 ppm

< 5%

< 0.1 ppm

3

H2S

0–30 ppm

< 5%

< 0.05 ppm

4

NH3

0–100 ppm

< 10%

< 1 ppm

5

VOC

0–10 ppm

< 5%

10ppb

6

SO2

0–10 ppm

< 5%

10ppb

Main technical parameters

Detection principle: photoionization detector(PID

Sampling method: pump suction

Detection range:1 ppbto 50 ppmand50 ppb to 6,000 ppm

optional Working power supply:

AC220V Output mode: wireless

GPRS Detection accuracy: ±

5%FS Response time:

<15s

Installation method: wall mounted or vertical pipe installation 6Service life: detector lamp tube

Month -20Working temperature:~50

Working humidity:0~95%RH

(No condensation) 630External dimensions:160××

515 mm Whole machine weight:

30KG

Typical applications




Online inquiry
  • Contacts
  • Company
  • Telephone
  • Email
  • WeChat
  • Verification Code
  • Message Content

Successful operation!

Successful operation!

Successful operation!