◆ Measuring medium | Liquid, gas, steam |
◆ nominal diameter | DN15-DN500 |
◆ Measure linearity | Liquid ± 0.75%, gas and vapor ± 1.0% |
◆ Measurement repeatability | Liquid 0.3%, gas and vapor ± 0.5% |
◆ Installation method | Clamping type (PN2.5MPa), insertion type, temperature and pressure compensation - type Other protocols for flange type (PN1.6MPa, PN2.5MPa, PN4.0MPa) |
◆ Output signal | 4-20mA/frequency, frequency/RS485 communication HART |
◆ Power supply | 24VDC、 On Battery |
◆ Explosion proof rating | Explosion proof type: Exd II CT6 Gb Intrinsic safety type: Exia II CT6 Ga |
Technical features:
High measurement accuracy, wide range, stable performance, safe and reliable, easy to operate.
◆ Ultra low power consumption, wide temperature plastic segment digital dynamic LCD display, variable brightness background light, standard two-wire or three wire power supply, can display instantaneous flow rate, flow velocity, and frequency when connected separately. Accumulated flow and other data can be selected from 4-20mA output, frequency pulse output, or RS-485 output. There are two connection methods between the converter and the sensor: integrated and separated, which are particularly suitable for use in high-temperature environments.
◆ Two line system, LCD with background light display.
◆The temperature and pressure compensation type does not require external temperature and pressure sensors.