Currently, most of the domestichospitalMost places such as consultation rooms, treatment rooms, medication rooms, dressing and examination rooms, emergency rooms, disinfection preparation rooms, dialysis rooms, and even ICUs use fan coil units for air conditioning. Once the heat exchange components inside the fan coil unit are contaminated with dust and bacteria, a large number of bacteria will grow, posing a risk of direct and cross infection to doctors and patients. On the other hand, it also reduces the heat exchange efficiency of the unit and increases energy consumption. Due to the residual pressure of ordinary fan coil units being within 50Pa, it is not possible to solve the above problems by installing ordinary filters.
If an independent purification unit is selected, not only will the cost be significantly increased, but the unit noise will also not easily meet the requirements of the operating environment; However, other conceptual disinfection and sterilization auxiliary equipment, although with good static indicators, have unsatisfactory dynamic effects in practical applications and high usage costs.
Ultra low resistance high efficiency filter solution
We have developed ultra-low resistance air supply and return devices by combining our own CJL series ultra-low resistance high efficiency filters, which effectively solve the air purification problem in places where fan coil units are used. Cleaned indoor air, prevented the occurrence of patient infections, and improved the working environment for medical staff. Due to the lack of major modifications to the existing air conditioning system, it is particularly suitable for use in some renovation projects.
This device is also suitable for air conditioning and ventilation systems in public places, meeting the requirements of the Ministry of Health's "Hygiene Standards for Centralized Air Conditioning and Ventilation Systems in Public Places", extending the cleaning cycle of pipelines, effectively improving the air quality in public places, and reducing the energy consumption of system operation.
Construction of ultra-low resistance high efficiency filter device
1. Box body of air supply and return device
2 ultra-low resistance filters
3 aluminum alloy louver (grille) air vents with filter screen
Technical parameters reference for ultra-low resistance high efficiency filters
Table 1 Ultra low resistance high-efficiency filter
Filter model (500×400×60) |
Initial resistance at different air volumes (Pa) |
|||
290m3/h |
440m3/h |
570m3/h |
700m3/h |
|
CJL—Ⅰ |
8 |
12 |
16 |
19 |
CJL—Ⅱ |
14 |
21 |
29 |
38 |
Filter model (500×400×100) |
Initial resistance at different air volumes (Pa) |
|||
290m3/h |
440m3/h |
570m3/h |
700m3/h |
|
CJL—Ⅰ |
3 |
6 |
10 |
13 |
CJL—Ⅱ |
8 |
11 |
15 |
19 |
Table 2 High Efficiency (500 × 400 × 60mm)
Filter model |
Rated air volume |
Filtration efficiency η% at different particle sizes |
|||||
m3/h |
≥0.3μm |
≥0.5μm |
≥0.7μm |
≥1.0μm |
≥2.0μm |
≥5.0μm |
|
CJL—Ⅰ |
400 |
61.8 |
61.6 |
79.2 |
86.3 |
94.2 |
96.4 |
CJL—Ⅱ |
400 |
74.8 |
79.4 |
87.4 |
89.8 |
93.8 |
95.8 |
Filter model |
Rated air volume |
Filtration efficiency at different sampling times% |
||||||
m3/h |
0.5min |
8th minute |
13th minute |
19.5th minute |
21st minute |
25th minute |
average |
|
CJL—Ⅰ |
400 |
97.96 |
99.07 |
99.30 |
98.50 |
99.00 |
99.29 |
98.85 |
CJL—Ⅱ |
400 |
99.34 |
99.34 |
99.39 |
99.47 |
99.26 |
99.43 |
99.37 |
The characteristics of our ultra-low resistance high efficiency filter
1. High energy efficiency
Reduce system energy consumption by over 30%.
2. Long service life
Assuming an indoor dust concentration of 0.15mg/m ³ and 8 hours of ventilation per day, it will take nearly 200 days to reach the rated dust capacity and require replacement of the filter.
3. Easy installation and maintenance
Connect the air supply and return ports of the fan coil unit to the ultra-low resistance air supply and return devices through hard or soft connections; The upper end of the box of this device has a lifting ring for easy lifting, and is equipped with aluminum alloy louvers, grilles, and nylon filters, which are ready to use immediately; Open the air vent to replace the filter.
Product specifications for ultra-low resistance high efficiency filters
Serial Number |
Product Name |
model |
Airflow (m3/h) |
Efficiency of 0.5 μ m |
Initial resistance (Pa) |
Outer edge size of air vent mm |
Box size mm |
Filter size mm |
Air duct interface size mm |
1 |
Ultra low resistance purification device (including static pressure box, ultra-low resistance filter, air outlet) |
R1600 |
1600 |
>85% |
<20 |
1200×600 |
1150×550×300 |
1100×500×100 |
1040×440 |
2 |
R 1500 |
1500 |
>85% |
<20 |
1100×600 |
1050×550×300 |
1000×500×100 |
940×440 |
|
3 |
R 1200 |
1200 |
>85% |
<20 |
1000×600 |
950×550×300 |
900×500×100 |
840×440 |
|
4 |
R 1000 |
1000 |
>85% |
<20 |
800×600 |
750×550×300 |
700×500×100 |
640×440 |
|
5 |
R 800 |
800 |
>85% |
<20 |
600×600 |
550×550×300 |
500×500×100 |
440×440 |
|
6 |
R 600 |
600 |
>85% |
<20 |
600×550 |
550×500×300 |
500×450×100 |
440×390 |
|
7 |
R 500 |
500 |
>85% |
<20 |
600×500 |
550×450×300 |
500×400×100 |
440×340 |
|
8 |
R 400 |
400 |
>85% |
<20 |
600×400 |
550×350×300 |
500×300×100 |
440×240 |
|
9 |
R 300 |
300 |
>85% |
<20 |
600×350 |
550×300×300 |
500×250×100 |
440×190 |
Note: Ultra low resistance high efficiency filter | Ultra low resistance high efficiency air filter can be customized according to user requirements!
Our company specializes in productionUltra-low resistance high efficiency filter | ultra-low resistance high efficiency air filterWelcome to inquire by phone!