VIP member
UPF series split type laboratory ultrapure water machine
UPF series split type laboratory ultrapure water machine
Product details
UPFType series split type laboratory ultrapure water machine
1、 Appearance design
Exquisite design of ABS engineering plastic, corrosion resistance, high safety insulation, and compliance with GLP safety requirements;
Microcomputer chip fully automatic control, multi-level menu operation, touch key design, user-friendly operation;
2、 Automatic display section
The LCD large screen displays Chinese menus, with clear and visible operating status, making it easy to operate;
UP ultra pure water resistivity (M Ω. cm) online monitoring display/water temperature online monitoring display;
RO pure water conductivity (μ s/cm), online monitoring display/water temperature online monitoring display;
When the water inlet pressure is insufficient, the system displays "water inlet under pressure";
When the ultra purification column fails, the system displays "UP column failure";
When the RO membrane fails, the system displays "RO membrane failure";
The system displays the flushing status of the pretreatment column, RO membrane, and UF membrane in Chinese (system flushing);
3、 Automatic control part
RO pure water excessive discharge function: Chinese displays "system discharge";
Automatic shutdown protection for water shortage/low water pressure system: Chinese displays "water inlet under pressure";
Automatic shutdown protection for water tank full system: Chinese display "pure water standby";
4、 Internal structure
Double pumps (high-pressure pump, circulating pump) and two-stage reverse osmosis design ensure the quality and quantity of water intake thoroughly;
Built in self flushing integrated pre processor, simple and beautiful;
Adopting a unique split flow ultra purification column to extend its service life;
The system has four measuring ranges for quantitative water intake: 500ml, 1000ml, 2000ml, and 5000ml;
The modular and quick connect design makes maintenance and upkeep of the equipment convenient and efficient;
5、 Optional parts
An optional 0.22 μ m aperture German original terminal capsule microfilter can be used as the ultrapure water inlet;
²reminder: Application scope of analytical laboratory ultrapure water: suitable for tissue examination, microbiological examination, chemical analysis, blood testing, toxicity testing, environmental analysis, gas chromatography, atomic absorption, liquid chromatography, etc
1、 Appearance design
Exquisite design of ABS engineering plastic, corrosion resistance, high safety insulation, and compliance with GLP safety requirements;
Microcomputer chip fully automatic control, multi-level menu operation, touch key design, user-friendly operation;
2、 Automatic display section
The LCD large screen displays Chinese menus, with clear and visible operating status, making it easy to operate;
UP ultra pure water resistivity (M Ω. cm) online monitoring display/water temperature online monitoring display;
RO pure water conductivity (μ s/cm), online monitoring display/water temperature online monitoring display;
When the water inlet pressure is insufficient, the system displays "water inlet under pressure";
When the ultra purification column fails, the system displays "UP column failure";
When the RO membrane fails, the system displays "RO membrane failure";
The system displays the flushing status of the pretreatment column, RO membrane, and UF membrane in Chinese (system flushing);
3、 Automatic control part
RO pure water excessive discharge function: Chinese displays "system discharge";
Automatic shutdown protection for water shortage/low water pressure system: Chinese displays "water inlet under pressure";
Automatic shutdown protection for water tank full system: Chinese display "pure water standby";
4、 Internal structure
Double pumps (high-pressure pump, circulating pump) and two-stage reverse osmosis design ensure the quality and quantity of water intake thoroughly;
Built in self flushing integrated pre processor, simple and beautiful;
Adopting a unique split flow ultra purification column to extend its service life;
The system has four measuring ranges for quantitative water intake: 500ml, 1000ml, 2000ml, and 5000ml;
The modular and quick connect design makes maintenance and upkeep of the equipment convenient and efficient;
5、 Optional parts
An optional 0.22 μ m aperture German original terminal capsule microfilter can be used as the ultrapure water inlet;
²reminder: Application scope of analytical laboratory ultrapure water: suitable for tissue examination, microbiological examination, chemical analysis, blood testing, toxicity testing, environmental analysis, gas chromatography, atomic absorption, liquid chromatography, etc
TECHNICAL INDEX | |||
Inlet water source | Total dissolved solids content TDS < 200ppm, water pressure 1.0-5.0kg/cm2The water temperature is between 5-45 ℃, | ||
Instrument model | UPF-10/20/30/40 (single-stage) | UPF-SF-10/20 (dual stage) | |
Water production capacity | 10/20/30/40L/H | 10/20L/H | |
Instantaneous water intake | 1.5-2 liters/minute (when the water tank is storing water) | ||
RO water production | RO water conductivity<1 μ s/cm (online monitoring) | ||
UP produced water quality | UP water production resistivity 10-15 M Ω. cm (online monitoring) | ||
Particles<1/ml | Microorganisms<1cfu/ml | TOC<30ppb | |
Host size (mm) | 350×420×500 | power supply | 220V/50HZ |
preprocessor | Built in dual column composite self flushing pre-processing | power | 24/48W |
Water tank configuration | 4G PE pressure drum | weight | 24/28kg |