UP-2001 semi-automatic UV oil analyzer
Under the condition of PH2, petroleum substances in water are extracted into n-hexane, and the extract is separated from oil and water. Polar substanc
Product details
Measurement principle:
Under the condition of pH ≤ 2, petroleum substances in water are extracted into n-hexane. The extract is separated from oil and water, and after removing polar substances such as animal and vegetable oils through a magnesium silicate adsorption column, the absorbance is measured at a wavelength of 225nm. The petroleum content and absorbance values follow Lambert Beer's law.
Scope of application:
Suitable for the determination of petroleum in surface water, groundwater, and seawater.
Reference standards:
HJ970-2018 Determination of Petroleum in Water Quality by UV spectrophotometry
Instrument features:
High precision: The grating is driven by a micrometer level precision screw, ensuring wavelength accuracy<± 0.1nm and a projection accuracy of ± 0.1%.
Good stability: Adopting thickened casting bottom plate, natural aging treatment, designed with unique optical system, low stray light, and low noise.
High accuracy: The instrument uses high-performance 1200/nm gratings and imported receivers to ensure high detection accuracy and good repeatability.
Calibration methods: single point rapid calibration, calibration curve calibration.
Automatic wavelength calibration: automatic wavelength calibration, automatic wavelength setting.
Automatic calculation: The instrument can freely set the volume of water sample and n-hexane, automatically calculate and display the solution concentration and water sample concentration.
Easy and fast operation: The instrument adopts a 128 * 64 bit dot matrix LCD display, which can directly display standard curves and test data. The host can store test data and can be optionally printed with a printer.
F2000-802 UV oil analyzer parameters:
Detection wavelength: 225nm
Reagent: n-hexane
Wave number accuracy: ± 0.1nm
Wave number repeatability: ≤ 0.1nm
Spectral bandwidth: 1.8nm
Stray light: 0.03% T
Detection limit: ≤ 0.005mg/L
Measurement repeatability<2%
Measurement accuracy ± 2%
Linear range of absorbance: 0.0000~1.9999AU
Linear relationship:> zero point nine nine nine
Measurement range: 0.0~50mg/L
Zui low detection concentration 0.001mg/L
Detection limit: 3SD < 0.1mg/L
Baseline flatness ± 0.001nm
Communication interface RS232 USB
Dimensions: 545 * 468 * 245 (nm)
Weight 16kg
Power supply AC110/220V 50/60Hz
Humidity<80%