Product project | Specification Description | quantity | Company |
GC-9800 Tovc chromatograph | Chromatograph host+dual gas path control system+dual injection system+amplification circuit control+dual CPU control system+host fault diagnosis sound and light Chinese display+dual output system | 1 | set |
detector | Dual FID detector (atmospheric monitoring type) | 2 | only |
chromatographic column | Specialized chromatographic column | 1 | root |
Workstation system | SP-2000 Dual Channel Multifunctional Workstation+Random Accessories +Computer+printer | 1 | set |
Thermal analysis | Automatic thermal analyzer+adsorption desorption device | 1 | set |
air sampler | Dual channel atmospheric sampler+activated carbon adsorption tube | 1 | set |
Starter Kits | Random giveaways (over 30 types) | 1 | set |
Standard sample | Standard sample | 1 | set |
Gas source | Hydrogen generator Air generator High purity nitrogen gas | 1 1 1 | set set pot |
Main performance characteristics: 11. It has a "0 ℃" protection function. When the temperature display of any channel is always "0 ℃", the heating will automatically stop to prevent the heating element from being damaged due to the constant heating of the chamber And there are prompts for the cause of the fault and alarm prompts (5) Automatic headspace injection; Temperature control indicators:
|
Attachment 1: (This machine is configured with an FID detector and retains an additional interface for adding any two detectors from 2.3.4.5.) 1. TCD detector (thermal conductivity cell detector) is the most widely used detector, suitable for inorganic gases and organic compounds, and is particularly suitable for constant analysis or analysis of components above one hundred thousandth. 2. FID detector (hydrogen flame ionization detector) has high sensitivity and is suitable for trace analysis of organic compounds. 3. ECD detector (electron capture detector) is a low-energy radioactive detector widely used in pesticide, atmospheric, and water pollution detection, suitable for analyzing organic complexes of halides, polysulfides, polycyclic aromatic hydrocarbons, and metal ions. 4. FPD detector (flame photometric detector) is suitable for analyzing pesticides containing sulfur and phosphorus, as well as monitoring trace amounts of organic pollutants containing sulfur and phosphorus in environmental analysis. 5. NPD detector (nitrogen phosphorus detector) is a mass detector suitable for analyzing nitrogen and phosphorus compounds with high sensitivity and selectivity; It can detect 5 × 10 (-13 times) g/s azobenzene nitrogen-containing compounds and 2.5 × 10 (-13 times) g/s phosphorus containing compounds, such as marathon pesticides. It has a high response to nitrogen and phosphorus compounds. And for other compounds, some response values are 10000 to 100000 times lower. |