TVOC sampling tube (Tenax TA adsorption tube)
TVOC sampling tube (Tenax TA adsorption tube)
Product details

TVOC sampling tube (Tenax TA adsorption tube)

TVOC sampling tube is used to collect air concentrations ranging from 0.5mg/m3100mg/m3Total volatile organic compounds(The specifications of TVOC comply with the "GB/T18883-2002 Indoor Air Quality Standard". The particle size of the adsorbent used is 0.18-0.25mm (60-80 mesh).

1588659197101955.jpg

type

specifications

Filling amount

notes

Thermal desorption type

Glass 6 × 150mm

200mg


Thermal desorption type

Glass 6 × 150mm

200mg


Thermal desorption type

Glass 6 × 150mm

200mg


Thermal desorption type

American standard stainless steel 1/4 × 3.5in

200mg


Thermal desorption type

Stainless steel 6.3 × 90mm

200mg

GB/T18883-2002

Thermal desorption type

Stainless steel 6 × 90mm

200mg


Thermal desorption type

Stainless steel 6 × 120mm

200mg


Thermal desorption type

Stainless steel 6 × 150mm

200mg


Thermal desorption type

Stainless steel U-shaped

200mg


The specifications of the thermal desorption sampling tube need to be selected based on the actual situation of the thermal desorption instrument and activator equipment

Reference national standard:

GB/T18883-2002 Indoor Air Quality Standards

Adsorption tube: outer diameterA stainless steel tube with an inner diameter of 6.3mm and a length of 5mm and a polished inner wall of 90mm. The sampling inlet of the adsorption tube is marked at one end. The adsorption tube can be filled with one or more adsorbents, and the adsorption layer should be placed in the heating zone of the desorption instrument. According to the density of the adsorbent, the adsorption tube can be filled with 200-1000mg of adsorbent, and the ends of the tube are blocked with stainless steel mesh or fiberglass wool. If multiple adsorbents are used in an adsorption tube, they should be arranged in the order of increasing adsorption capacity and separated by glass fiber wool. The adsorbent with the weakest adsorption capacity should be loaded at the sampling inlet of the adsorption tube.

GB 50325-2010 (2013 edition) Code for Indoor Environmental Pollution Control of Civil Building Engineering

Tenax TA adsorption tubes can be glass tubes or stainless steel tubes with smooth inner walls, containing 200mg of Tenax TA adsorbent with a particle size of 0.18mm to 0.25mm (60 mesh to 80 mesh). Before use, nitrogen should be used to heat and activate. The activation temperature should be higher than the desorption temperature, and the activation time should not be less than 30 minutes until there are no impurity peaks. When the flow rate is 0.5L/min, the resistance should be between 5kPa and 10kPa.

HJ 583-2010 Determination of Benzene Compounds in Environmental Air Solid Adsorption/Thermal Desorption Gas Chromatography Method

The material of the sampling tube is stainless steel or hard glass, and the filling inside should not be less than200mg Tenax (60-80 mesh) adsorbent (or other equivalent adsorbent), fixed at both ends with stainless steel mesh or quartz wool with pores smaller than the adsorbent particle size to prevent the adsorbent from falling off. The position of the adsorbent inside the tube should be at least 15mm away from the inlet end of the tube, and the length of the adsorbent filled should not exceed the size of the heating zone.