Functional Features
Maximum output capacity: voltage up to 576 V, current up to 120 A, ensuring stable output under full load conditions.
Minimum current output: The minimum limit is 1 mA, which is the basis for the starting test of the tested electric energy meter.
◉ It has various energy measurement methods such as forward and reverse active energy, four quadrant reactive energy, etc.
◉ Mobile measurement and control platform: It can observe or control the output of measurement values through its LCD touch screen, and can be manually checked.
◉ Specialized verification software: Full automatic or full automatic calibration of the verified table, data recording, analysis, management, and certificate export.
◉ Multi meter calibration table: 3-16 meter positions can be selected, and the table is equipped with interfaces for power output, optical/electrical pulse, communication, etc., meeting various testing needs.
Harmonic function (optional): It can load harmonics with adjustable amplitude and phase from 2 to 21 times, and complete the harmonic impact test.
◉ Crimp connection (optional): Optional semi-automatic crimping connection device, no manual connection required, easy to use with a quick gauge.
Three phase voltage/current output

Power output/measurement of electrical energy

Frequency/Phase/Harmonic

output characteristic
Voltage range: 0-576 V, load capacity: 15 VA/(phase/meter position)
Current range: 1 mA~120 A, load capacity: 30 VA/(phase/meter position)
Adjustment fineness: 0.002% * RG, 6-digit decimal display
Selection Guide