1、 Product Introduction:
※TC-100EType standardCOD(cr)The measuring instrument follows international standards(ISO)In accordance with national standards(GB)The basic principle ensures reflux heating with slight boiling2The digestion operation for hours, the preparation and addition of reagent solution are all in accordance withGBLaw consistency ensures reliable and accurate analysis results.
※ standardCODThe digestion device adopts microcomputer technology for timed control of far-infrared electric furnace plates, which can8One12Simultaneously heating the digestion reflux device. To achieve the goals of energy conservation, reducing power load, and improving efficiency.
The instrument adopts a glass burr reflux tube instead of a spherical reflux tube, and uses air cooling technology instead of tap water cooling, which can not only save water and standardize the instrument, but also improve the safety of instrument use.
※ standardCODChemical solution preparation, operation andCODThe calculation is completely in accordance withGB11914—89, lower than50mg/LofCODThe accuracy of water samples can be improved by diluting titrants and oxidants, which is higher than1000mg/LofCODWater samples can be measured by diluting them proportionally.
※ national standardGB11914—89Standardized analytical methods have been developed to determine the chemical oxygen demand for water qualityCOD(cr)The measurement steps strictly specify the conditions and indicators of the method, such as heating and digestion time, solution acidity, oxidant and catalyst dosage. It is obvious that the water qualityCOD(cr)There are strict conditions for the measurement, and any operation that violates these conditions will affect the accuracy of the measurement.
2、 Technical specifications:
1Temperature measurement: National standard method
2Heating time:(180℃)<10min
3Dissolving time:2h(at most2hour30Minutes, with a time adjustment amplitude of10Minutes)
4Measurement range:0~1000mg/L、0~10000mg/L(Dilution of water sample)
5Measurement time: not exceeding2h
6Measurement error: Potassium hydrogen phthalate standard solution(500mg/L)The relative standard deviation is not greater than5%
Industrial organic wastewater(500mg/L)The relative standard deviation is not greater than8.0%
7Environmental temperature:5~40℃
8Heating power:700W(Instrument power adjustable)
9Dissolve the sample:8One12individual
10Electricity Source:AC 220V±22V,50HZ
3、 Technical features:
1This technology adopts a two in one technology of standard digester and constant temperature heater, with a unique appearance design
2Can be correct8A or12Heating a sample simultaneously
3It has the advantages of fast heating rate, high thermal energy utilization rate, uniform heating, and long service life.
4Equipped with air cooling function, economical and practical
5Thorn reflux tube, better cooling effect
6Fast cooling time and accurate data analysis
7Fast heating time, constant and uniform temperature
8Temperature and time can be set arbitrarily
4、 Product configuration
1StandardCODDissolver host 1tower
2Burrs will flow through the pipe8/12branch
3Dissolving bottle8/12individual
4Power cord 1root
5Certificate of Conformity 1share
6Warranty card 1share
7Instruction manual 1share