Single phase multifunction meter
Multi functional power meters use advanced microprocessors and digital signal processing technology. Through direct AC sampling, they can measure elec
Product details
  • Single phase multifunction meter
  • Multi functional power meters use advanced microprocessors and digital signal processing technology. Through direct AC sampling, they can measure electrical parameters such as current, voltage, active power, reactive power, power factor, frequency, active energy, and reactive energy. They can also be equipped with switch input output, analog transmission output, power pulse output, and RS485 network communication functions. As an advanced intelligent and digital front-end acquisition component for power grids, this instrument is widely used in various control systems, industrial automation, intelligent buildings, intelligent distribution panels, and switch boxes. It has the characteristics of easy installation, simple wiring, easy maintenance, small engineering quantity, and programmable input parameters on site. Capable of networking different PLCs and industrial control computer communication software in the industry.



    Detailed Introduction




    overview
    Multi functional power meters use advanced microprocessors and digital signal processing technology. Through direct AC sampling, they can measure electrical parameters such as current, voltage, active power, reactive power, power factor, frequency, active energy, and reactive energy. They can also be equipped with switch input output, analog transmission output, power pulse output, and RS485 network communication functions. As an advanced intelligent and digital front-end acquisition component for power grids, this instrument is widely used in various control systems, industrial automation, intelligent buildings, intelligent distribution panels, and switch boxes. It has the characteristics of easy installation, simple wiring, easy maintenance, small engineering quantity, and programmable input parameters on site. Capable of networking different PLCs and industrial control computer communication software in the industry.
    TECHNICAL INDEX
    transport
    enter
    measure
    measure
    apparent
    show
    electricity
    press
    RATING AC100V, 400V (please specify when ordering)
    overload Duration: 1.2 times Instantaneous: 2 times/10 seconds
    power consumption < 1VA (per phase)
    impedance >500KΩ
    accuracy RMS measurement, accuracy level 0.5
    electricity
    flow
    RATING AC 1A, 5A (please specify when ordering)
    overload Duration: 1.2 times Instantaneous: 10 times/10 seconds
    power consumption < 0.4VA (per phase)
    impedance <2MΩ
    accuracy RMS measurement, accuracy level 0.5
    frequency 45-55Hz、 Precision 0.01 Hz
    power Total harmonic content of voltage and current (2-31st harmonic content)
    electric energy Positive and negative active and reactive energy measurement
    display Programmable, switchable, looping (LED/LCD) display
    Electric energy display range 0.01-KWh (or KVar)
    power supply scope of work AC/DC 80-270V special requirements can be customized
    power consumption <5VA
    input Switching input 4-channel switch input, remote dry contact mode (optional)
    output Digital Interface RS-485, MODBUS-RTU protocol (optional)
    Switching Output 4-channel switch output, relay passive contact mode (optional)
    analog output 4-channel analog transmission output, 4-20mA/0-20mA/4-12-20mA/0-5V/1-5V (optional)
    environment work environment -10-55 ℃, relative humidity<85%. Non corrosive gas environment, altitude<2000m
    Environment -55-85 ℃, relative humidity<85%
    secure pressure resistance Input/power>2KV, input/output>2KV, power/output>1KV
    isolation Input, output, and power supply to the chassis>100M Ω


    List of models and functions of single-phase multifunctional power meters
    model measure display Appearance and installation dimensions Peripheral functions (optional, to be specified when ordering)
    A B C D E digital communication Switch Module Transmission output
    HL-42K1E U、I、KW、KVar、KWh、
    KVarh、Hz、cosφ

    LED

    120 120 83 112 112 RS-485
    MODBUS
    -RTU
    4-way entry
    Route 4 departs
    4DI/4DO
    4-channel transmission
    4-20mA
    0-20mA
    4-12-20mA
    0-5V
    1-5V
    (Optional)
    HL-42K1EY U、I、KW、KVar、KWh、
    KVarh、Hz、cosφ
    LCD 120 120 83 112 112
    HL-96K1E U、I、KW、KVar、KWh、
    KVarh、Hz、cosφ

    LED

    98 98 83 90 90 RS-485
    MODBUS
    -RTU
    4-way entry
    Route 4 departs
    4DI/4DO
    4-channel transmission
    4-20mA
    0-20mA
    4-12-20mA
    0-5V
    1-5V
    (Optional)
    HL-96K1EY U、I、KW、KVar、KWh、
    KVarh、Hz、cosφ
    LCD 98 98 83 90 90
    HL-80K1E U、I、KW、KVar、KWh、
    KVarh、Hz、cosφ

    LED

    84 84 83 76 76 RS-485
    MODBUS
    -RTU
    2-channel switch
    Quantity output
    4-channel transmission
    4-20mA
    0-20mA
    4-12-20mA
    0-5V
    1-5V
    (Optional)
    HL-80K1EY U、I、KW、KVar、KWh、
    KVarh、Hz、cosφ
    LCD 84 84 83 76 76
    HL-72K1E U、I、KW、KVar、KWh、
    KVarh、Hz、cosφ

    LED

    75 75 90 67 67 RS-485
    MODBUS
    -RTU
    2-channel switch
    Quantity output
    4-channel transmission
    4-20mA
    0-20mA
    4-12-20mA
    0-5V
    1-5V
    (Optional)
    HL-72K1EY U、I、KW、KVar、KWh、
    KVarh、Hz、cosφ
    LCD 75 75 90 67 67
    HL-45K1E U、I、KW、KVar、KWh、
    KVarh、Hz、cosφ

    LED

    50 50 83 45 45 RS-485
    Or 2-channel transmission output
    Route 2 departs
    2DO
    RS-485
    Or 2-channel transmission output
    HL-45K1EY U、I、KW、KVar、KWh、
    KVarh、Hz、cosφ
    LCD 50 50 83 45 45
    HL-48K1E U、I、KW、KVar、KWh、
    KVarh、Hz、cosφ

    LED

    51 99 83 91 45 Route 2 departs
    2DO
    RS-485
    Or 2-channel transmission output
    HL-48K1EY U、I、KW、KVar、KWh、
    KVarh、Hz、cosφ
    LCD 51 99 91 45 45

    Wiring example diagram

    Note: 1 "★" is the current input terminal. Please refer to the product's random wiring diagram for specific wiring methods and parameters.
    Order List
    When placing an order, please specify in detail the required model, input signal ratio, and expansion function module.
    Example 1: Model: HL-42K1E
    Power supply: AC220V
    Input: 10KV/100V, 200A/5A
    Communication: RS485/MODBUA-RTU
    Function extension: 4DI/4DO
    Quantity: 88 units