Bond Elut Certify extraction column is a mixed mode adsorbent containing non-polar C8 and strong cation exchange (SCX) functional groups. Certify is most commonly used to extract alkaline (cationic) drugs from urine and blood, but it can also effectively extract a variety of compounds from various aqueous matrices. You can fully trust the Certified series products with uniform performance, which support automated and high-throughput analysis of samples in multiple specifications.
Common matrix |
Main extraction mechanism |
Type of compound |
Urine, plasma, saliva, blood, and biological fluids |
Non polar and strong cation exchange |
Alkaline drugs, alkaline abused drugs |
Bond Elut Certify
Explanation |
Company |
40 μ m filler particle size |
120 μ m filler particle size |
Large Capacity Column Tube (LRC) | |||
130 mg,10 mL |
50/pack |
||
130 mg,10 mL |
500 per pack |
||
200 mg,10 mL |
500 per pack |
| |
200 mg,10 mL |
50/pack |
||
300 mg,10 mL |
50/pack |
||
Straight pipe column | |||
50 mg,3 mL |
50/pack |
| |
130 mg,1 mL |
100 per pack |
||
130 mg,3 mL |
50/pack |
||
130 mg,3 mL |
500 per pack |
| |
130 mg,3 mL, Tabless |
50/pack |
T |
|
130 mg,6 mL |
30/pack |
| |
130 mg,6 mL, Tabless |
500 per pack |
TJ |
|
200 mg,3 mL |
50/pack |
| |
200 mg,6 mL |
30/pack |
| |
300 mg,3 mL |
50/pack |
| |
300 mg,3 mL |
500 per pack |
| |
300 mg,3 mL, Tabless |
50/pack |
T |
T |
300 mg,6 mL |
30/pack |
| |
500 mg,6 mL |
30/pack |
||
1 g,6 mL |
30/pack |
||
Other types | |||
Prospekt Column, 800 Series |
96/pack |
|
Bond Elut Certify VersaPlate specifications
Explanation |
Packing particle size (μ m) |
25 mg |
50 mg |
100 mg |
Pre installed 96 hole plate |
40 |
7540901C |
| |
VersaPlate Tube* |
40 |
7550901C |
*Column tube needs to be inserted into VersaPlate substrate, part number:
Bond Elut Certify 96 well Plate
Explanation |
25mg |
50mg |
100mg |
1mL round hole plate |
A4960925 |
A4960950 |
A496091C |
2mL square orifice plate |
A3960925 |
A3960950 |
A396091C |
utilizeBond Elut Certification extracts phenyl cycloheximide (PCP) from human urine
Adsorbent activation: |
100% methanol, then 0.1M phosphate buffer, pH 6.0 |
Sample processing: |
Add 2mL of 0.1M phosphate buffer solution (pH 6.0) and matrix standard sample to 5mL of urine sample. Vortex oscillation, measure whether the pH is between 5.0 and 7.0. Pass through the adsorbent at a flow rate of<4mL/min. |
Rinse off interfering substances: |
1. 1mL of 1.0M AcOH, then vacuum dry for 5 minutes; 2. 6mL methanol, drain for 2 minutes; |
Elution of analytes: |
2mL 2% NH4OH ethyl acetate solution; |
Silicone substrate: irregular shape of 40 μ m or 120 μ m, acid washed treatment, 60 μ m? The average pore size
● Bonded phase: Mixed mode adsorbent, octyl (C8) and benzenesulfonic acid (SCX)
End group sealing: No
Typical carbon load: 9.0%
Main retention mechanism: dual mode, non-polar and strong cation exchange interaction
Application sample types: urine, biological fluid samples
● Suitable for forensic science and drug abuse monitoring