Performance characteristics of Dongyang water-cooled chiller:
1. All pipeline insulation designs are designed to prevent local convection in the body's pipelines.
2. The cooling temperature range is 5 ℃ -35 ℃.
3. Independent temperature controller for antifreeze protection.
4. Stainless steel insulated water tank.
5. Control the phase sequence protection of the control circuit and control the high and low voltage switches of the refrigerant system.
6. Hydrophilic finned condenser with better heat transfer effect and faster heat dissipation.
Both the compressor and pump have overload protection.
8. Adopting a large capacity shell and tube evaporator, it has good refrigeration effect and can be applied to environments with high temperatures.
9. Refrigerant usedR22The cooling effect is good.
10. OptionalR407CEnvironmentally friendly refrigerant, closer to nature.
Parameters of water-cooled chillerTechnical Table:
model Parameters
|
unit | TY-03W | TY-04W | TY-05W | TY-08W | TY10W | TY-12W | TY-15W | |
power supply | V | 3 Φ 380V 50Hz | |||||||
Refrigeration capacity | Kw | 9.59 | 12.43 | 15.91 | 24.85 | 31.83 | 38.37 | 50.14 | |
Kcal/h | 8250 | 10700 | 13700 | 21400 | 27500 | 33000 | 43200 | ||
Rated input power | Kw | 2.62 | 3.55 | 4.5 | 6.75 | 8.25 | 10.5 | 12.75 | |
Maximum operating current | A | 6.7 | 8.4 | 10.5 | 16.5 | 20.4 | 24.6 | 31.8 | |
make cold a pharmaceutical or other chemical preparation |
type | R22 | |||||||
filling amount | Kg | 1.7 | 2.2 | 2.8 | 4.4 | 5.6 | 6.8 | 8.4 | |
control mode | capillary | Capillary/Thermal Expansion Valve | |||||||
press shrink machine |
type | vortex | Spiral/piston type | ||||||
power | Kw | 2.25 | 3.0 | 3.75 | 6.0 | 7.5 | 9.0 | 11.25 | |
cold step back water |
amount of water | m3/h | 2.06 | 2.67 | 3.42 | 5.34 | 6.85 | 8.24 | 10.78 |
Inlet and outlet pipe diameter | 1" | 1" | 1" | 1.5" | 1.5" | 2" | 2" | ||
cold freeze water |
amount of water | m3/h | 1.65 | 2.14 | 2.74 | 4.27 | 5.47 | 6.59 | 8.62 |
Inlet and outlet pipe diameter | 1" | 1" | 1" | 1.5" | 1.5" | 2" | 2" | ||
water pump |
power | Kw | 0.37 | 0.37 | 0.37 | 0.75 | 0.75 | 1.5 | 1.5 |
pressure | Kpa | 242 | 242 | 242 | 290 | 290 | 205 | 205 | |
External dimensions | long | mm | 980 | 980 | 980 | 1400 | 1400 | 1400 | 1600 |
wide | mm | 520 | 520 | 520 | 700 | 700 | 700 | 800 | |
tall | mm | 960 | 960 | 960 | 1350 | 1350 | 1350 | 1500 | |
Water tank capacity | m3 | 0.055 | 0.055 | 0.055 | 0.18 | 0.18 | 0.23 | 0.33 |
model Parameters
|
unit | TY-20W | TY-25W | TY-30W | TY-35W | TY-40W | TY-45W | TY-50W | |
power supply | V | 3 Φ 380V 50Hz | |||||||
Refrigeration capacity | Kw | 67.14 | 81.53 | 99.91 | 117.28 | 129.06 | 148.68 | 153.91 | |
Kcal/h | 57800 | 70100 | 86000 | 100800 | 112000 | 127800 | 132300 | ||
Rated input power | Kw | 16.5 | 19.76 | 25.34 | 29.4 | 31.77 | 38.6 | 42.5 | |
Maximum operating current | A | 42.1 | 48.5 | 58.3 | 65.4 | 75.4 | 80.6 | 88.4 | |
make cold a pharmaceutical or other chemical preparation |
type | R22 | |||||||
filling amount | Kg | 10.0 | 12.6 | 15.0 | 18.4 | 20.0 | 22.6 | 25 | |
control mode | Capillary/Thermal Expansion Valve | ||||||||
press shrink machine |
type | Spiral/piston type | |||||||
power | Kw | 15.0 | 18.75 | 22.5 | 26.25 | 30.0 | 33.75 | 37.5 | |
cold step back water |
amount of water | m3/h | 14.44 | 17.54 | 21.32 | 25.22 | 27.7 | 31.98 | 33.09 |
Inlet and outlet pipe diameter | 2" | 2.5" | 3" | 3" | 3" | 3" | 3" | ||
cold freeze water |
amount of water | m3/h | 11.55 | 14.03 | 17.06 | 20.18 | 22.19 | 25.58 | 26.48 |
Inlet and outlet pipe diameter | 2" | 2" | 2.5" | 3" | 3" | 3" | 3" | ||
water pump |
power | Kw | 1.5 | 2.2 | 2.2 | 3.7 | 3.7 | 4.0 | 4.0 |
pressure | Kpa | 220 | 220 | 250 | 250 | 250 | 280 | 280 | |
External dimensions | long | mm | 1600 | 1600 | 1800 | 1800 | 2200 | 2200 | 2200 |
wide | mm | 800 | 800 | 950 | 1950 | 1150 | 1150 | 1150 | |
tall | mm | 1500 | 1500 | 1650 | 1650 | 1700 | 1700 | 1700 | |
Water tank capacity | m3 | 0.33 | 0.37 | 0.46 | 0.46 | 0.76 | 0.76 | 0.76 |
|
Note:1.High voltage pumps can be ordered according to special customer requirements;
2. The above specifications are designed for a 50Hz/380V power supply;
3. Please specify before placing an order for low-temperature or acid resistant machinery;
4. The above product standard design has a cold water inlet temperature of 12 ℃;
5. Product specifications are subject to change without prior notice
1. The chilled water pump cannot operate without water in the water tank;
2. Please try to avoid continuous switching when operating the switch;
When the frozen water temperature reaches the set temperature, the compressor will automatically stop running, which is a normal phenomenon;
4. The temperature switch should be avoided from being set below 5 ℃ to prevent the evaporator from freezing; (Excluding low-temperature freezers)
To ensure the cooling effect and maintain the best condition, please regularly clean the condenser, evaporator, and water filter
1. High pressure water pumps can be ordered according to special customer requirements2. The above specifications are designed for 50HZ/380V power supply
3. Please specify before placing an order for low-temperature or acid resistant machines4. The above products are designed according to standards, with a cold water inlet temperature of 12 ℃
5. Product specifications are subject to change without prior notice.
Timely delivery: Confirm customer orders and ship them as soon as possible. It takes only one day to arrive in the Pearl River Delta region. 3-5 days in remote areas
Our services
1Product packaging
The company is a professional manufacturer of chillers/ice water machines/freezers, screw feeders, and crushers/Manufacturers of injection molding machine auxiliary equipment such as crushers, color mixers, and mixers. The machines are packaged in films and cardboard boxes from the factory to prevent water ingress or friction. At the same time, wooden boxes are packaged according to customer requirements to prevent damage to the goods during transit.
2Product transportation
The company is a member customer of Deppon, Simbond and other large logistics enterprises, and can enjoy the advantage of priority delivery. At the same time, it can arrive in Guangdong Province and surrounding cities of the the Pearl River Delta within 1-2 days, and in remote cities within 3-5 days. At the same time, it can arrange door-to-door delivery or door-to-door picking and other services; At the same time, small corresponding accessories are delivered to surrounding cities in about one day through cooperation with large express delivery companies such as Shunfeng, Shentong, and Suer. Other remote cities can quickly reach the customer's company according to the express delivery situation (except for special natural disasters such as earthquakes, flash floods, mudslides, etc.).
3Product after-sales service
On site commissioning of large equipment: Our company conducts commissioning and installation of newly purchased large units for customers. Customers should notify our service department in writing 3 days before commissioning, so that our company can arrange commissioning personnel to arrive at the site for commissioning within the time required by the customer; The machine comes with a 12-month free warranty and provides free technical support.
Lifetime maintenance service: During the warranty period, if the machine encounters any abnormal situations, our company will provide free inspection and maintenance, but does not include human damage caused by the user. After the warranty period, we will continue to track and implement lifelong maintenance service. If replacement parts are needed, only the cost of the parts will be charged.
Timely, thoughtful, and comprehensive service: In order to relieve users' worries, our company has equipped a strong after-sales service team with multiple specialized after-sales service personnel in various regions across the country. Our company has sufficient reserves of various spare parts, and we promise to ensure that maintenance personnel will send professional maintenance personnel to the site as soon as possible to solve the problem after receiving the customer's request for maintenance service call and confirmation.