Shanghai Gas Component Analyzer
Shanghai gas component analyzer analysis: using chromatographic separation method to complete the work. Due to the different components of the mixed g
Product details

Shanghai Gas Component Analyzer

Shanghai Gas Component Analyzerworking principle:

Analysis: Use chromatographic separation method to complete the work. Due to the different components of the mixed gas, the length of time it stays in the chromatographic separation column varies, and the separation sequence is based on the order of gas weight from light to heavy. So this way, a detection instrument can be used to separate different gas components over time. By the order in which gas components are separated, we can know the names of various components in the mixed gas. Gas chromatograph for natural gas analysis, equipped with a two-stage pressure stabilization system, a six way valve injection system for packed columns, a thermal conductivity detector, and a gas analysis chromatographic workstation; It can achieve full analysis of hydrocarbon components such as oxygen, nitrogen, methane, ethane, carbon dioxide, propane, isobutane, n-butane, n-pentane, isopentane, and C6+in natural gas with a single injection.

Calorific value analysis: Chromatographic calorific value analysis calculates the calorific value of gas by analyzing the gas components and using a converted calculation method to determine the content and calorific value of combustible components in the components

Technical indicators:

Temperature control

Detector FID

Temperature control range: 6 ℃ -400 ℃ at room temperature (increments of 0.1 ℃)
Cheng Sheng order: 13 orders
Cheng Sheng rate: 0.1 ℃ -50 ℃/min (incremental 0.1 ℃)

Detection limit: ≤ 8 × 10-12 g/s (n-hexadecane)
Baseline noise: ≤ 2×10-13A/H
Linear range: ≥ one hundred and six
Stable time: less than 20 minutes

Detector TCD

FPD detector

Sensitivity: ≥ 5000mV · ml/mg (n-hexadecane)
Baseline noise: ≤ 30uV (hydrogen with a carrier gas of 99.999)

Detection limit: ≤ 5×10-12g/s(N)
Baseline noise: ≤ 2×10-13A/H

Detector ECD

Detector NPD

Detection limit: ≤ 5×10-12g/s(N) (r-666)
Baseline noise: ≤ 2×10-13A/H

Detection limit: ≤ 5×10-12g/s(N)
Baseline noise: ≤ 2×10-13A/H

Shanghai Xuansheng Scientific InstrumentsManufacturers of synthetic gas detectors/analyzersOur company's gas chromatograph is in a prominent position in the domestic instrument industry. We solemnly promise to provide a one-year warranty for the entire instrument, with an annual fee and lifetime after-sales service.