Agilent 1100 Four Element Pump System
Model: Agilent 1100 Four Element Pump System
Detailed description: Four element low-pressure gradient system configuration with reverse control, original software, and automatic sampler
Configuration: One G1311A quaternary infusion pump, one G1322A online deaerator, one G1314A ultraviolet detector, one set of G1316A original column temperature box, one G1313A automatic sampler, one G1323B handheld controller, one original mobile phase tray, and one set of G2170BA original Agilent data processing system software.
Original factory price: 520000
Discounted price: 170000 yuan
Origin: Agilent, USA
Color: Over 80% new
Product Introduction:
Origin: United States
The Agilent 1100 series is aimed at the industry and has established new industry standards for liquid chromatography in response to regulations. Since 1996, we have installed over 130000 sets of 1100 components and more than 55000 sets of chemical workstation data processing systems worldwide, making us the highest market share liquid chromatography system for a single model. The Agilent 1100 series components have a unique appearance design and flexible combination methods; Excellent system performance indicators; A graphical workstation friendly interface; The intelligent maintenance system and comprehensive regulatory certification function, continuously innovating and launching new components, improve the analysis field of Agilent liquid chromatography.
The full range of Agilent 1100 pump systems
The capillary liquid phase pump system controlled by an electronic flow control valve (EFC) has high accuracy and a wide flow rate range. The column flow rate range is 1-20ul/min; 10-100ul/min (optional)
0.001-2.5m/min (EFC closed state)
High pressure preparation pump system, unit or dual high-pressure preparation pump
Flow rate range: 0.001-100m1/min
Analytical pump system
Flow rate range:
Unit pump: 0.001-10m3/min
Binary pump: 0.001-5m3/min
Four element pump: 0.001-10m3/min
Agilent 1100 series injection system with a complete range of varieties
Standard manual sampler (analytical or preparation type)
● Standard automatic sampler
Sample bottle capacity: up to 100 pieces (2mlx100)
Injection volume: 0.1-100ul (0.1-1800ul) optional
● Micro disc automatic sampler
Sample bottle capacity: 2x96 (orifice plate), 2x386 (orifice plate) or 100x2ml
Injection volume: 0.1-100ul (standard part)
0.1-1500ul optional
● Micro standard automatic sampler/micro disc automatic sampler
Injection volume: 0.01-8ul (standard); 0.01-40ul (optional)
● Constant temperature standard automatic sampler/micro disc automatic sampler
Temperature range: 4-40 ℃ with adjustable step size of 1 ℃
220 type microporous plate automatic sampler - combined chemical sample management system
Sample bottle capacity: up to 12 microplates (96 well plate, 384 well plate) for various specifications of test tubes
Injection volume: 0.1-5ul; 0.1-20ul
Agilent 1100 series detectors
Variable wavelength scanning ultraviolet detector (VWD)
Wavelength range: 190? 600nm
● Multi wavelength detector (MWD)
Wavelength range: 190? 950nm (dual light source)
● Diode Array Detector (DAD)
Wavelength range: 190? 950nm (dual light source)
Fluorescence detector (FID)
Excitation wavelength: 200-700nm;
Emission wavelength: 280-900nm
Spectral storage: Full spectrum
Differential Refraction Detector (RID)
Temperature control: Room temperature+5 ℃ to 55 ℃
Built in automatic purge valve and automatic solvent circulation valve
Electrochemical detector (ECD)
LC/MS quadrupole mass detector (MSD)
LC/MS ion trap mass detector (Trap MSD)
Column temperature box and deaerator components
● Column temperature box
Temperature range: 10 ℃ to 80 ℃ at room temperature
Optional: Column switching valve
Vacuum online deaerator
Technical parameters:
Agilent 1100 Pump System Series
The capillary liquid phase pump system controlled by an electronic flow control valve (EFC) has high accuracy and a wide flow rate range. The column flow rate range is 1-20ul/min; 10-100ul/min (optional)
0.001-2.5m/min (EFC closed state)
High pressure preparation pump system, unit or dual high-pressure preparation pump
Flow rate range: 0.001-100m1/min
Analytical pump system
Flow rate range:
Unit pump: 0.001-10m3/min
Binary pump: 0.001-5m3/min
Four element pump: 0.001-10m3/min
Agilent 1100 series injection system with a complete range of varieties
Standard manual sampler (analytical or preparation type)
● Standard automatic sampler
Sample bottle capacity: up to 100 pieces (2mlx100)
Injection volume: 0.1-100ul (0.1-1800ul) optional
● Micro disc automatic sampler
Sample bottle capacity: 2x96 (orifice plate), 2x386 (orifice plate) or 100x2ml
Injection volume: 0.1-100ul (standard part)
0.1-1500ul optional
● Micro standard automatic sampler/micro disc automatic sampler
Injection volume: 0.01-8ul (standard); 0.01-40ul (optional)
● Constant temperature standard automatic sampler/micro disc automatic sampler
Temperature range: 4-40 ℃ with adjustable step size of 1 ℃
220 type microporous plate automatic sampler - combined chemical sample management system
Sample bottle capacity: up to 12 microplates (96 well plate, 384 well plate) for various specifications of test tubes
Injection volume: 0.1-5ul; 0.1-20ul
Agilent 1100 series detectors
Variable wavelength scanning ultraviolet detector (VWD)
Wavelength range: 190? 600nm
● Multi wavelength detector (MWD)
Wavelength range: 190? 950nm (dual light source)
● Diode Array Detector (DAD)
Wavelength range: 190? 950nm (dual light source)
Fluorescence detector (FID)
Excitation wavelength: 200-700nm;
Emission wavelength: 280-900nm
Spectral storage: Full spectrum
Differential Refraction Detector (RID)
Temperature control: Room temperature+5 ℃ to 55 ℃
Built in automatic purge valve and automatic solvent circulation valve
Electrochemical detector (ECD)
LC/MS quadrupole mass detector (MSD)
LC/MS ion trap mass detector (Trap MSD)
Column temperature box and deaerator components
● Column temperature box
Temperature range: 10 ℃ to 80 ℃ at room temperature
Optional: Column switching valve
Vacuum online deaerator
Main features:
The Agilent 1100 series is aimed at the industry and has established new industry standards for liquid chromatography in response to regulations.
Since 1996, we have installed over 130000 sets of 1100 components and more than 55000 sets of chemical workstation data processing systems worldwide, making us the highest market share liquid chromatography system for a single model.
The Agilent 1100 series components have a unique appearance design and flexible combination methods; Excellent system performance indicators; A graphical workstation friendly interface; Intelligent maintenance system and comprehensive regulatory certification function, constantly innovating and launching new components, improving the analysis field of Agilent liquid chromatography