The seawater membrane SW30HR-380 has been improved by Dow Chemical Company to provide users with various high-quality seawater desalination reverse os
Product details

Seawater membraneSW30HR-380

Dow Company has improved various high-quality seawater desalination for usersreverse osmosisMembrane components are used to save investment and operating costs in seawater desalination systems. Dow Chemical Company's products integrate excellent membrane performance with fully automated and high-precision manufacturing processes, thereby increasing the water production rate of seawater desalination systems to the highest level.

The Dow seawater desalination membrane SW30HR-380 has an extremely high desalination rate, which can reduce the water production cost of seawater desalination membrane systems and has the following advantages:

The seawater desalination system designed with this component can operate at low pressure, thereby saving operating costs; Or obtain more water production at lower pressure to improve efficiency
The SW30HR-380 has extremely high salt and boron removal rates, which can meet the standards of the World Health Organization (WHO) and other strict standards for drinking water.
The use of this component in the segmented seawater desalination membrane system will not weaken the performance of the downstream section.
The SW30XHR-400i membrane has an area of 400 square feet and can be cleaned and maintained within a pH range of 1-13. It is the seawater desalination membrane element with the highest desalination rate. The use of single machine reverse osmosis can meet strict water quality requirements. Can be used for food hygiene and drinking water requirements.
The SW30XHR-440i has a maximum membrane area of 440 square feet and the widest inlet channel. Ensure the improvement of equipment water extraction.


Product specification for Dow seawater desalination membrane SW30HR-380:

PRODUCT MODEL Item number Membrane area ft2 (m2) Operating pressure psi Water production rate gpd (m3/d) Stable desalination rate% Lowest desalination rate%
SW30HR-380 135137 380(35) 800 6,000(23) 99.7 99.6
SW30XHR-400i 293991 400(37) 1,200 6,000(23) 99.82 99.7
SW30XHR-440i 440(41) 1,200 6,600(25) 99.82 99.7
SW30HR LE-400 217822 400(37) 1,200 7,500(28) 99.8 9.65
SW30HR LE-400 i 246512 400(37) 1,200 7,500(28) 99.8 99.65
SW30HR LE-440 i 440(41) 1,200 8,200(31) 99.8 99.65
SW30HR LE-370/34i 297258 370(34.4) 1,200 6,700(25) 99.8 99.65
SW30XLE-400 i 219219 400(37) 1,200 9,000(34) 99.75 99.6
SW30XLE-440 i 440(41) 1,200 9,900(37.5) 99.75 99.6
SW30ULE-400 i 259124 400(37) 1,200 11,000(416) 99.7 99.55
SW30XLE-440 i 440(41) 1,200 12,000(45.4) 99.7 99.65


1. The water production is based on testing conditions: 32000 ppm of sodium chloride, 5 ppm of boron, 800 psi (5.5 MPa), -77 ° F (25 ° C), pH 8, and a recovery rate of 8%.
2. The flow rate of a single component may vary by+/-15%.
3. Sales specifications may vary and there may be design modifications.
4. Parameter variation range, ensuring+/-5%.


model Channel specifications Size A Size B Size C
SW30HR-380 28mil 1016mm 29mm 201mm

This component is compatible with an 8-inch 800psi fiberglass membrane housing and can replace any other brand of 8-inch seawater desalination membrane.

Operating parameters of Dow seawater desalination membrane SW30HR-380

Diaphragm Type: Polyamide Composite Membrane
Maximum operating temperature: 45 ℃ (113 ℃)oF)
Maximum operating pressure: 600psi (41bar)
Maximum pressure difference: 15 psi (1.0 bar)
Continuous operation pH range: 2-11
Short term cleaning pH range (30 minutes): 1-13
Maximum feedwater flow rate: 70gpm (16m)3/h)
Maximum Water Pollution Index SDI 5
Maximum turbidity of feedwater: 1NTU
Free chlorine tolerance:<0.1ppm

aWhen pH>10, the maximum temperature for continuous operation is 35oC (95oF);
bPlease refer to the cleaning guidelines in document number 609-23010;
cUnder certain conditions, the presence of free chlorine and other oxidants in the incoming water can cause serious membrane damage. As oxidation damage is not covered by the product warranty, FilmTec recommends removing residual free chlorine in the pre-treatment before the membrane. Please refer to technical data 609-22010 for further assistance.

Dow Membrane Component Maintenanceimportant information
It is necessary to correctly start the reverse osmosis water treatment system to prevent damage to the membrane components caused by water flow or hydraulic shock when the membrane system is ready for operation. Following the correct startup sequence helps ensure that system operating parameters comply with design specifications, thereby achieving the established design goals for system water quality and quantity. Before the initial startup program of the membrane system, the pre-treatment system debugging, membrane component loading, instrument calibration, and other system checks of the membrane system should be completed. For more information, please refer to the application literature titled "Startup Sequence".

oltremareRO reverse osmosis systemoperation guide
During startup, shutdown, cleaning, or other processes, to prevent potential membrane damage, any sudden pressure or cross flow rate changes in the coiled components should be avoided. During the startup process, we recommend gradually transitioning from a static state to an operational state according to the following procedure:
The water supply pressure should gradually increase within the time range of 30-60 seconds.
The designed cross flow velocity value should gradually reach within 15-20 seconds.
The product water should be drained within the first hour.

Storage of Dow Membrane Componentsgeneral information
Once the component is wetted, it should always be kept moist.
If the user does not strictly follow the operating limits and guidelines set in this specification, the limited warranty will be invalidated.
When the system is shut down for a long time, it is recommended to immerse the membrane components in a protective solution to prevent microbial growth. The standard storage solution contains 1.5% by weight of sodium bisulfite (food grade).
Users should be responsible for the impact of using incompatible chemicals and lubricants on components.
A single pressure vessel? The maximum allowable pressure drop is 50psi (3.4 bar).
Always avoid creating back pressure on the water side of the product.