Function and purpose:
SY-2000The portable gas analyzer adopts electrochemicalPIDprinciple, is an analyzer designed specifically for portable measurement needs, which is easy to carry, has fast response, and stable performance. It does not require consumables during operation, has sensitive response, and is easy to operate.
It is suitable for environmental air monitoring, industrial (cement, chemical, metallurgical, power, etc.) and other scientific research units for detectionSO2, VOC, NOX, H2S, NH3, O3, PM10, PM2.5 are independent sensors, while benzene, phenols, non methane total hydrocarbons, formaldehyde, butanol, 1,4-butanediol, and ozone are measured using composite sensors and converted by coefficientsSpecialized instruments for various gas concentrations.
Product Features:
n Using imported sensors with high accuracy;
n Equipped with cross interference compensation function
n External quick filter interface, easy to maintain
n 8Inch touch screen, easy to operate

n standard configurationAPPFunction, convenient for customers to view data on their mobile phones at any time;
n Configure a high-temperature sampling gun with a charging range of 6-8 hours.
measurement component |
sensor type |
measurement range |
resolution |
precision |
CO2 |
infrared |
0-1% |
0.01% |
±0.1% |
NOX |
UV/Electrochemical |
0-1-100ppm |
10ppb/2ppm |
Absolute ± 0.3% or relative 3% |
SO2 |
UV/Electrochemical |
0-1-100ppm |
10ppb/2ppm |
Absolute ± 0.3% or relative 3% |
CO |
electrochemistry |
0-2ppm |
10ppb |
Absolute ± 0.3% or relative 3% |
CH4 |
electrochemistry |
0-10ppm |
10ppb |
± 2% |
PM2.5 |
Light scattering sensor |
0-5000ug/m3 |
5um/m3 |
±1% |
PM10 |
Light scattering sensor |
0-8000ug/m3 |
5um/m3 |
1% |
O3 |
electrochemistry |
0-10ppm |
0.01 ppm |
Absolute ± 0.3% or relative 3% |
VOC |
PID |
0-20-10000ppm |
0.01 ppm |
Absolute ± 0.3% or relative 3% |
NH3 |
electrochemistry |
0-50ppm |
0.01 ppm |
Absolute ± 0.3% or relative 3% |
HCL |
electrochemistry |
0-20ppm |
0.01 ppm |
Absolute ± 0.3% or relative 3% |
H2S |
electrochemistry |
0-10ppm |
0.01 ppm |
Absolute ± 0.3% or relative 3% |
HF |
electrochemistry |
0-10ppm |
0.01 ppm |
Absolute ± 0.3% or relative 3% |
stench |
composite type |
0-100OU |
0.1 OU |
Absolute ± 0.3% or relative 3% |
formaldehyde |
electrochemistry |
0-50ppm |
0.01 ppm |
±1% |
methanol |
electrochemistry |
0-50ppm |
0.01 ppm |
±1% |
Technical Specifications
Display: LCD8inchdisplay screen
Sampling: Built in high-performance diaphragm pump, flow rate 1-1.5L/min
Usage environment: Temperature -10 ℃~+50 ℃, humidity: ≤ 85% RH
battery6-8Hourly battery life
Weight: Approximately 5-10KG
Attachment: Carrying backpack, instruction manual, charger, built-in zero calibration tube
Software content: Navigation map data query, real-time data display, curve chart, bar chart, historical record curve chart, historical data, etc.
3preprocessing
u Sampling valve
u Filter (fiberglass filter element)
u Intelligent sensors for humidity and pressure
After switching the three-way switching valve, the instrument can be calibrated with standard gas.
Intelligent sensors for humidity and pressure
Humidity and pressure sensors can monitor the working condition of the preprocessing system in real time. When there are abnormal humidity and pressure in the sample gas in the circuit, the signal is transmitted to the PLC as soon as possible. The PLC will take centralized measures and issue alarms to ensure the stability of the preprocessing and the accuracy of the analyzer.
4.Sampling gun
Sampling is carried out in high temperature environments, and the sampler is made of special ceramic material, which can withstand up to3000度以上。Combined with our company's unique designed built-in circulating air-cooled cooling structure, it ensures the protection of the sampler when inserted into high-temperature environments, extends its service life, and cools the sample gas.
4.communication
Portable analyzers can communicate with computers and transfer data packets to the computer. At the same time, an APP with unlimited GPRS function can also be optionally selected.
Application scenarios:
² Online analysis of fixed pollution source exhaust gas;
² Online analysis of air environment gases