Changhui Automation System Co., Ltd
Home>Products>SWP-LED series single loop digital/light column display controller
SWP-LED series single loop digital/light column display controller
SWP-LED series single loop digital/light column display controller
Product details

instrument for drawing circles check
speak bright
use
environment
ambient temperature
0~50
relative humidity
≤85RH Avoid strong corrosive gases
Supply Voltage
Conventional AC220V+10-15% (50Hz ± 2Hz)
Special type AC85~260V - Switching Power Supply DC24V ± 2V - Switching Power Supply
power consumption
≤6W
input
signal
analog quantity
Thermocouples: Standard thermocouples - B, S, K, E, J, T, WRe3-25, etc
Resistance: Standard thermistor - Pt10, Pt100.1, Cu50, Cu100 and other remote pressure resistors, etc
Current: 0~10mA, 4~20mA, 0~20mA, etc. - Input impedance ≤ 250 Ω
Voltage: 0~5V, 1~5V, mV, etc. - Input impedance ≥ 250K Ω
Switching quantity
Pulse signal: waveform - rectangular, sine or triangular wave
Radiance - greater than 4V (or as per user requirements)
Scope -0~10KHz (or as per user requirements)
Contact signal: electrical contact input signal
output
signal
analog output
DC 0~10mA (load resistance ≤ 750 Ω) DC 4~20mA (load resistance ≤ 500 Ω)
DC 0~5V (load resistance ≥ 250K Ω) DC 1~5V (load resistance ≥ 250K Ω)
Switching Output
Relay control output - relay ON/OFF return differential. AC 220V/3A DC 24V/5A (resistive load)
Controllable silicon control output - SCR (thyristor zero crossing trigger pulse) output, 0.5A/400V
Solid state relay output - SSR (Solid state relay control signal) output, 6~24V/30mA (voltage not adjustable)
Bidirectional thyristor output - SOT thyristor output, 5A/400V
Communication output
Interface Method - Standard Serial Bidirectional Communication Interface RS-485 RS-232 C, RS-422, etc
Baud rate -300~9600Bps instrument internal free setting
Feed output
DC 24V load ≤ 30mA
measurement accuracy
± 0.2% FS ± 1 word or ± 0.5% FS ± 1 word
resolution
± 1 word
measuring range
-1999~9999 words
Display mode
-1999~9999 word measurement value display -1999~9999 character setting value display, LED working status display
way
control/The alarm method is to bring back the upper or lower limit alarm of the difference (which can be freely set by the user)
Control accuracy
± 1 word
temperature compensation
0~50 ℃ digital temperature automatic compensation
Print Control
You can choose to directly connect various types of string printers(such as LQ-300K, TPuP series micro printers, etc.), with a printing interface of RS-232C
Printing accuracy
Same instrument accuracy
Parameter setting
Panel touch sensitive button settings, parameter settings permanently saved after power failure, parameter settings password locked
Protection method
Input circuit disconnection alarm(When thermocouple or resistor input), relay output status LED indication, input over/under range alarm
Power undervoltage automatic reset, abnormal operation automatic reset (Watch Dog)

SWP-LED series digital display control instrument type chart

typename
take the place of a sign or object indicating number
speak bright
SWP-
□□
-□
-□□
-□
-□
LEDSeries digital display controller
Appearance characteristics
C
S
Horizontal display instrument*1
Vertical display instrument*1
External dimensions
1
4
7
8
9
48×48mm
96×48mm(Horizontal),48×96mm(Vertical)
72×72mm
160×80mm(Horizontal), 80×160mm(Vertical)
96×96mm
Control function
01
03
04
Measurement display
Three position control
Four limit control or four limit alarm output
Communication method
See alsoCommunication method
Output
See alsoControl output mode
Input Type
□□
See alsoInput Type
The first alarm method
N
H
L
No alarm (can be omitted)
Upper limit control/Alarm (four limit control)/call the police2H*2
Lower limit control/Alarm (four limit control)/call the police2L*2
Second alarm method
N
H
L
No alarm (can be omitted)
Upper limit control/Alarm (four limit control)/call the police2H*2
Lower limit control/Alarm (four limit control)/call the police2L*2
Feed output
P
DC24VFeed output
Power supply mode
W
T
DC24Vpower supply
AC85-260VPower Supply (Switching Power Supply)
AC220VPower supply (linear power supply, can be omitted)*3

SWP-LED series light column measurement display control instrument type chart

type name
take the place of a sign or object indicating number
speak bright
SWP-
ST□
□□
-□
-□□
-□
-□
-□
-□
Light column display measuring instrument
External dimensions
8
160×80mm(Horizontal), 80×160mm(Vertical)
Control function
01
03
04
Measurement display
Three position control
Four limit control or four limit alarm output*2
Communication method
See alsoCommunication method
Output
See alsoTransmission output mode
Input Type
□□
See alsoInput Type
The first alarm method
N
H
L
No alarm (can be omitted)
Upper limit control/Alarm (four limit control)/call the police2H*2
Lower limit control/Alarm (four limit control)/call the police2L*2
Second alarm method
N
H
L
No alarm (can be omitted)
Upper limit control/Alarm (four limit control)/call the police2H*2
Lower limit control/Alarm (four limit control)/call the police2L*2
Feed output
P
DC24VFeed output
Power supply mode
W
T
DC24Vpower supply
AC85-260VPower Supply (Switching Power Supply)
AC220VPower supply (linear power supply),Can be omitted)
Power supply mode
X
Horizontal display
Vertical display (can be omitted)
pour1C80C90The series is0.8inchLEDDisplayS80C70C40The series is0.56inchLEDdisplay, C10The series is0.32inchLEDDisplay.
pour2Four limit control or four limit alarm output is controlled by four relays,Users can modify internal parameters to set desired control or alarm modes.(Four limit control/Alarm onlyT.C80S80andC90Series provided,2HRepresenting two upper limit controls/call the police,2LRepresenting two limit controls/call the police) .
pour3Light column display controllerSWP-ST803-01-23-HL-X(Horizontal Table)“S”Can be omitted).

★ Communication method:

code
0
2
3
4
8
9
Communication method
No communication
RS-232
lpt
RS-422
RS-485
Special specifications
★ Communication protocol: SWP communication protocol is used at the factory.
If the user has ordered a special communication protocol, please indicate it when placing the order.
When selecting instruments with printing ports, some instruments cannot meet the printing function. When ordering, choose instruments that can meet their requirements in terms of functionality.
★ Control output mode:

Selection code
0
1
2
3
4
5
6
7
8
9
Output
no-output
relay
4~20mA
0~10mA
1~5V
0~5V
SCR output
SSR output
Special specifications
SOT output
SCR thyristor zero crossing trigger pulse output SSR solid-state relay control output SOT bidirectional thyristor output
★ Transmission output mode:

Selection code
0
2
3
4
5
8
Output
no-output
4~20mA
0~10mA
1~5V
0~5V
Special specifications

★ Input type:

code
Input Type
measuring range
code
Input Type
measuring range
code
Input Type
measuring range
01
B
400~1800℃
09
Pt100.1
-199.9~320.0℃
17
30~350Ω
-1999~99999 d
02
S
0~1600℃
10
Cu50
-50.0~150.0℃
18
Special specifications
User to be determined
03
K
0~1300℃
11
Cu100
-50.0~150.0℃
19
4-20mA square meter
-1999~99999 d
04
E
0~1000℃
12
4~20mA
-1999~99999 d
20
0-10mA square root
-1999~99999 d
05
T
-199.9~320.0℃
13
0~10mA
-1999~99999 d
21
1~5V square root
-1999~99999 d
06
J
0~1200℃
14
1~5V
-1999~99999 d
22
0~5V square root
-1999~99999 d
07
WRe3~25
0~2300℃
15
0~5V
-1999~99999 d
23
Fully switchable input
08
Pt100
-200~650℃
16
0~20mA
-1999~99999 d
Note: To switch inputs, only the secondary parameters of the instrument need to be set. For detailed information, please refer to the "User Manual".

Note 3: C70 and C10 have no frequency signal input. Factory default switch power supply.