Rapid determination instrument for crude oil water contentsummary:
The product is a floor standing integrated multifunctional measuring device. This can be measured simultaneously4Oil sample,6Support oil sample. Zui is suitable for single well testing in oil production teams with large assay volumes
Product features:
1. The shell is made of cold-rolled sheet deep drawing and surface electrostatic spraying technology.
2. The temperature setting automatically controls the temperature, and the digital display has the advantages of large heating area, fast heating, uniform temperature, precise temperature control, and time-saving and labor-saving.
3. Corrosion resistance, aging resistance, durability, safety and reliability.
4. Novel and aesthetically pleasing design, easy to operate, and effective in use.
Technical performance:
No need to build a laboratory bench, easy to move, one machine for multiple purposes, the entire laboratory procedure can be completed on one machine;No need for tap water, no need to equip heating equipment such as electric heating plates and water baths;Magnetic demulsification, fast oil-water separation, no sample flushing or sudden boiling in the determination of medium and high water content;Safe and energy-saving, easy to use, no need for manual monitoring, and will automatically shut down when needed.Voltage used:220V.Zui High Power:5KW.
Specifications:500ml .1000ml
Rapid determination instrument for crude oil water contentforeword
DGN1000MLXB6Series is a type of automated crude oil water content measurement device. According to the requirements of national measurement standards, in productionHL500Under the premise of the model, it has been developed againDGN1000It not only overcomes the disadvantages of traditional measuring instruments such as difficult temperature control, easy sample flushing, high energy consumption, low efficiency, and insecurity.
The product has been tested by experts from Shengli Oilfield and Zhongyuan Oilfield, and it is believed that this instrument has complete performance, high degree of automation, safety, energy saving, and easy operation. It is a reliable instrument for various oil production manufacturers, gathering and transportation stations, scientific research units, and oil post laboratories.
1DGNCharacteristics and working principle of the series
1. This instrument adopts a heating sleeve for non open flame heating, with fast heating, low power, uniform heating, and high efficiency.
2. Magnetic stirring is a closed magnetic stirring method that avoids sudden boiling and achieves rapid oil-water separation.
3. In the automation and self-control parts, the timer is the heating power switch, which sets the required time and automatically shuts down the power when the time is up. By using gas sensing probes instead of manual monitoring, if the height of oil and gas rise exceeds the specified standard, the instrument automatically cuts off the power supply and starts the axial flow fan to quickly cool down the furnace body, thereby avoiding the phenomenon of sudden boiling and sample collision and achieving safety.
4. Equipped with a pure water automatic cooling tank, it prevents the yellowing and scaling of glass instruments, and solves the problem of water shortage in field operations.
5DGNThe model is equipped with a glass instrument quick drying oven and a heating air duct for condensing air drying. In order to address the impact of external cold air on the receiver, it is equipped with a temperature protection device, which solves the problem of premature condensation of water vapor and backflow of water droplets, achieving the goal of rapid evaporation of moisture.HL1000Type, equipped withXAHot air flow rapid constant temperature dilution instrument, which can be heated at once6It can also dry glass instruments.
IIindicate
This instrument relies on high-temperature distillation to increase the temperature of crude oil, so that the temperature of water in the oil reaches100Above the temperature, it turns into steam and is magnetized to allow the iron substances in the oil to rotate at high speed, causing the emulsified water to quickly separate and the water in the oil to evaporate rapidly, achieving the goal of rapid measurement. Therefore, the diluent added should not exceed150Ke (Sampling)200Otherwise, a large amount of light component gas will quickly enter the condenser tube. Once it encounters the gas sensing probe above, the instrument will automatically stop heating and enter a cooling state, which cannot achieve the rapid effect. Due to differences in scale, facilities, and workload among different units,DGN(HL)The series of crude oil water content measuring instruments are equipped with the following specifications for reference:
model | specifications | Amount | Dilution amount | voltage | Measurement time | Quantity of samples tested | accuracy |
DGN500B2type | 500ⅹ2 | 10can | 25can | 220V | 12-15 | 2 | 100% |
DGN500B2type | 500ⅹ6 | 10can | 25can | 220V | 12-15 | 6 | 100% |
DGN500Dtype | 500ⅹ12 | 10can | 25can | 220V | 12-15 | 12 | 100% |
DGN500B1type | 500ⅹ4 | 10can | 25can | 220V | 12-15 | 4 | 100% |
DGN1000type | 1000ⅹ2 | 20can | 100can | 220V | 20-25 | 2 | 100% |
DGN1000type | 1000ⅹ6 | 20can | 100can | 220V | 20-25 | 6 | 100% |
DGN1000type | 1000ⅹ4 | 20can | 100can | 220V | 20-25 | 4 | 100% |
Due to different water contents in crude oil, the sampling amount also varies100Crude oil can be diluted with diluent40Ke -50Ke, take crude oil50Add diluent30The distillation time remains unchanged,HL1000Type of crude oil extraction100G, diluent60Ke.
The purpose of crude oil determination is to completely separate oil and water and accurately measure the water content of crude oil. Therefore, whether it is rapid or long-term distillation, only by measuring accurate values can the requirements be met. Users can adopt this methodHL1000Comparative experiments are conducted between the measurement results of the series products and other instruments. If there is indeed an error in this product, our factory is responsible for repairing or returning it. Practice has proven that usingHL1000Type of instrument only used20In minutes, the original instrument can pass through60-90Accuracy measured in minutes, saving solvents2.6Double energy-saving5times,Improved work efficiency4More than double,If users have strict regulations on distillation time and solvent dosage, this product can also be used for addition400The specific operation method for long-term distillation of solvent gasoline (xylene) remains unchanged,Just adjust the voltage to150VJust enough. Our factory implements three guarantees for our products from the date of shipment, and is responsible for training and installation,Free two-year warranty and on-site service.
IIICombination installation method
1. Main components: The instrument body is divided into three parts①COD②Condenser pipe bracket③Purified water automatic cooler, glass moisture analyzer, cooling water conduit, etc.XAThe hot air flow crude oil rapid constant temperature dilution instrument is an important accessory.
2. Place the measuring instrument on the laboratory table, and then insert the condenser bracket into the square holes on both sides of the measuring instrument.
3. The condenser bracket is a push-pull bracket. During installation, the entire glass instrument can be placed inside the heating sleeve to check if it is vertical. If it is not vertical,The bracket can be adjusted by moving it left and right to achieve free loading and unloading, and then tighten the screws. The tightness of the condenser tube clamp should be such that the condenser tube does not slide down.
4. Purified water circulating cooler. Installation can be designed according to the length conditions of the laboratory bench. Place it flat with the measuring instrument and on the right side of the measuring instrument. If the laboratory table is too small, it can also be placed on the ground below the table.
5. Connection of cooling water conduit: The connection method is series connection, which refers to connecting the upper opening of the circulating water outlet group * and the lower opening of the second group, and then connecting the lower opening of the remaining group * to the condenser water nozzle, and connecting the upper opening of the second group to the cooling water return pipe.
6. Connection and setting of the cooler: Turn off the two switches on the cooler panel, plug the power plug directly into the power socket on one side of the cooler, and connect the other end to an AC power source (cooling and circulating water can be controlled separately),Do not affect each other.)Turn the switch of the refrigeration digital instrument to the upper limit position (top) and then rotate the corresponding upper limit setting potentiometer knob. At this time, the desired upper limit temperature value will be displayed, usually set at20℃. Then turn the switch to the lower limit setting position (below) and rotate the corresponding lower limit setting potentiometer knob. At this point, the desired lower limit temperature value will be displayed, usually set at10℃The difference between the upper limit set temperature value and the lower limit set temperature value should not be less than5℃After setting, turn the switch to the measurement position (middle), and the actual temperature value will be displayed. Turn on the cooling switch,You can start working now,No need for manual control.Add more than three-quarters of water into the stainless steel bucket. Then turn on the switches separately and test the circulating water and cooling compressor separately. When testing the circulating water pump, immediately listen to whether the pump starts after turning on the switch. If it does not start, there will only be a slight sound, which is often caused by long-term disuse. The impeller inside the pump is stuck and cannot rotate. The power supply of the pump should be turned off immediately to prevent the pump from being burned out by prolonged power on. Use a small stick about 30 centimeters long at the outlet to gently poke the impeller inside the pump to make it move, and then turn on the power for testing. Some water pumps come with a movable screw at the end of the factory, so there's no need to poke it with a small stick. Just use a screwdriver to tighten it. The cooler automatically starts and shuts down under the control of the measuring instrument (it can also be manually turned off but cannot start automatically).
4Operating procedures
1. The power of each thermal group of the instrument is equal, and there is only one probe. When in use, after each group of oil samples is prepared, they must be loaded into the heating sleeve of the instrument and heated for distillation at the same time, otherwise the timer will lose its timing function.
2. The loading and unloading methods of the flask, receiver, and condenser tube: After the crude oil and diluted gasoline are loaded, the flask must be held by hand, and the receiver must be inserted into the flask with the left hand. Observe whether the grinding mouth of the flask and the grinding mouth of the receiver are tightly combined, otherwise there will be air leakage. Use your left hand to push the condenser tube up to the top dead center, and your right hand to push it up. Insert the grinding mouth on the top of the receiver and the grinding mouth on the bottom of the condenser tube tightly into place. Align your left and right hands with the heating sleeve and apply slight force until the bottom of the flask and the bottom of the heating sleeve are tightly combined.
3. The usage method of automatic control probe: The probe is a substitute for manual monitoring of guards. Its principle is that oil and water are heated, and the oil and gas rise and come into contact with the probe to function. When in use, it must be inserted into the upper opening of the heating condenser tube1/3Otherwise, automatic control cannot be used. The digital temperature control meter corresponding to the probe, such as a "voltage regulating instrument", should generally set the temperature at60Degree. For instruments without voltage regulation, the temperature should be set at35The temperature can be adjusted according to the actual situation of the oil sample, such as when the oil sample reaches the condenser tube, to accelerate the separation of oil and water3/4You can set the temperature of the temperature control instrument lower, for example, if the oil sample does not flush into the condenser tube1/2You can set the temperature of the temperature control instrument higher, which is related to the ambient temperature and oil sample density. Therefore, it needs to be flexibly applied. The adjustment of the intelligent temperature control meter is described in the following instructions.
Attention: Be sure to see the convex groove on the probe clearly, align it and apply slight force, and slowly insert it. If the probe is not inserted into the instrument, the instrument cannot function properly. However, after inserting the probe, it can be placed behind the instrument instead of in the condenser tube.
4. Timer operation method: The timer has both mechanical timing and digital instrument timing. The mechanical timer is the main power switch of the instrument. When using it, it must be rotated clockwise. Align the white line with the scale on the instrument panel and release it. The timer will automatically reverse the timing. When the set time is up, it will automatically shut down. Do not rotate counterclockwise. Reverse it to normally on and will not automatically shut down.
The instrument timer is the power conversion switch for heating, blowing, and cooling of the instrument. When using, first adjust the middle time of the digital device in the timer(h)Divide(m)Second(s)Set the time again, the digital display will start counting from zero when the power is turned on. Once the set time is up, the heating will automatically stop and the blowing and cooling will begin. The digital display will maintain the current number, achieving timed control. Reset the time, or turn on the reset switch on the left side of the timer at any time, and then immediately turn it off to start counting again from zero. If you don't want to time, you can set the time to the maximum99Hour.
The significance of time numbers:①When the middle of the digital device is set to(h)The hour represents the hour, and the timing range is1Divide -99hour99Minutes (the preceding digits represent hours, and the following digits represent minutes).
②When the middle of the digital device is set to(m)The time table is divided, and the timing range is1In seconds -99divide99Seconds (the first digit represents minutes, the last digit represents seconds).
③When the middle of the digital device is set to(s)Chronometer seconds, timing range is0.01In seconds -99.99Seconds (the preceding digits represent seconds),The numbers behind represent0.01Seconds).
5. Voltage adjustment method: Voltage adjustment is also an adjustment of heating power* The electricity can be adjusted for secondary use160V(Observe the indication scale of the instrument voltmeter). After heating for five minutes, observe the height of the oil and gas rising in the condenser. Generally, the height should be in the middle of the condenser. If you cannot reach this height, you can slightly adjust the pressure knob clockwise until the oil and gas are stable1/2Stop here. Remember this reading, use it again next time, adjust it according to this voltage once, and generally do not touch it.
6. The usage method and regulations of the mixer: There are two types of this instrument: full mixing and single group mixing. It is determined based on the amount of oil taken. This instrument has two stirring functions, one is magnetic stirring and the other is iron ion stirring. If taking less than 50 grams of crude oil, only one stirrer should be placed in each instrument, and the designated set of heating flasks should be placed. Other groups do not need to have agitators, just rely on the iron ions in the crude oil to stir. If 100 grams of crude oil are taken, each group must have a stirrer. Each bottle can only contain one mixer.
7. Method to start stirring: Due to the continuous rotation of the stirring magnetic field, the temperature and viscosity of the crude oil just added are very low, and the stirring element is stationary. At this time, the stirring element may not necessarily rotate. After heating for 1-2 minutes, the crude oil is diluted, and then press the magnetic stirring switch downwards,Gently turn the speed control knob, and all mixers will start up.
8. Comprehensive use and inspection: After connecting the power, turn the function key to the automatic control position, and the instrument power indicator light will turn on, indicating that the power has been connected. When each group needs to heat and distill the oil sample, put it into the heating sleeve of the instrument, turn on the switch for each group that needs to be heated upwards, and rotate the timer clockwise (the white line on the knob points to the 12-15 minute mark for the required time). At the same time, the cooler automatically starts, and the heating indicator lights for each group that needs to be heated are on, indicating that it is working. When the set time is up, it will automatically shut down and the reading will be ready.
5、 Emergency troubleshooting
1. If the operation is improper or too much oil is taken, the diluted gasoline preparation is incorrect, causing sample flushing and crude oil flushing into the receiver, manual control can be used: immediately turn the function switch to the sample cooling position. The instrument will automatically power off and at the same time turn on the fan to quickly cool down the heating part through air cooling. Distillation can continue after the temperature drops.
2. During the distillation process, if blue smoke is found to be emitted from the heating jacket, it indicates that the bottom of the flask has exploded. The heating jacket must be turned off and the flask must be removed. Do not continue distillation. If crude oil has already flowed into the heating jacket, adjust the voltage to 70V and slowly heat and evaporate until there is no smoke. Only then can it continue to be used. Otherwise, this heating sleeve will quickly burn out.
3. If the timer is found to be damaged, it does not affect its use, but it cannot time. At this point, rotate the timer counterclockwise to the normally on position for use. Whether the crude oil has been completely distilled can be checked by whether there are water droplets on the inner wall of the flask. No water droplets indicate that the water in the oil has completely evaporated.
VIprecautions
1. Before use, it is necessary to carefully read the instruction manual. Operate according to the instructions, do not open or ask other manufacturers for repairs without authorization, otherwise our factory will not be responsible.
2. It is normal to have white smoke and odor during repeated use.
3. Due to differences from traditional distillation methods, the cooling water flow rate must be increased, and it is strictly prohibited to change the gasoline dilution ratio of the new distillation method.
4. This instrument is for rapid distillation and cannot use a 30cm fine mouth (12 #) condenser. Moisture determination must be performed using a diameter of 19 # or higher