Qiulai Technology Co., Ltd
Home>Products>QBeam-2M-FW laser spot analyzer
Product Groups
Firm Information
  • Transaction Level
    VIP member
  • Contact
  • Phone
  • Address
    Room 1315, Silver Zun, Zunbao Building, Jianggan District, Hangzhou City, Zhejiang Province
Contact Now
QBeam-2M-FW laser spot analyzer
Wavelength range: 350-1100nm; Maximum resolution: 2 million pixels; Built in filter wheel, including three ND filters (ND4/ND9/ND10)
Product details
overview

The qBeam-2M-FW laser spot analyzer is lightweight and flexible, enabling real-time measurement with high sensitivity and resolution. The application software is simple and easy to use, capable of measuring various parameters such as beam width, shape, position, power, intensity, etc., and has beam divergence calculation M2Additional functions such as value calculation and analysis.

The wheel consists of threeND filters (ND4/ND9/ND10), users can easily switch filters by turning the wheel. Filters can overlap to achieve ideal attenuation.

features:

  • Lightweight and flexible
  • Real time beam size and Gaussian regression
  • real time2D/3D beam curve
  • accessiblePixel spacing of 3 μ m
  • Measurable Xiaoda60 μ m light spot
  • Built in filter wheel

Software features:

  • Easy to use
  • Second moment, Gaussian regression, blade edge, etc
  • Calculation of beam divergence
  • M2Value calculation

Main applications:

  • Laser beam analysis: contour, beam size, position, divergenceM2
  • Laser'sQC
  • Monitor the center point of multiple beams
specifications
specifications
Microsoft operating system XP/7/8/10
drawing
Application Expansion Types DLL
Related accessories Beam reducer~x2, can be used to measure larger laser beams, with a maximum beam power of 1kW. C-mount mounting accessories are convenient for installing other optical accessories. 50/100mm socket
sensitivity ~1.2nWatt/mm2 @ 632.8nm / ~0.5mWatt/mm2 @ 1310nm
storage temperature -20℃-85℃
operation temperature -10℃-70℃
power supply 5V DC, via USB
Filter* ND4: Transmittance 14% @ 632.8nm/ND9: Transmittance 0.5% @ 632.8nm/ND10: Transmittance 0.03% @ 632.8nm
damage threshold All filters 50W/cm2
shutter Up to 50Hz (depending on image size)
Adjustable parameters Exposure time, image size
saturation intensity ~5μWatt/mm2 @ 632.8nm
wavelength range 350-1100nm
minimal beam size 60 microns
Maximum Resolution 1920 (H) x 1080 (V) 2 million pixels
Photosensitive size 5.76mm x 3.24mm
pixel size 3μm
detector CMOS
Online inquiry
  • Contacts
  • Company
  • Telephone
  • Email
  • WeChat
  • Verification Code
  • Message Content

Successful operation!

Successful operation!

Successful operation!