307WMicrocomputer based conductivity meter
This modelMicrocomputer based conductivity meterSuitable for measuring the conductivity value of liquids, based on which you can analyze and calculate the purity of water.
A little manual calibration(Chinese version):
The instrument is calibrated using the constant input method. During calibration, you only need to input the value marked on the electrode into the instrument, and the storage chip can remember this value. Even if the power is turned off, it will not be lost.
The instrument is calibrated using the constant input method. During calibration, you only need to input the value marked on the electrode into the instrument, and the storage chip can remember this value. Even if the power is turned off, it will not be lost.
One point automatic calibration(International version):
The instrument can perform some automatic calibration with standard conductivity solution. During calibration, the instrument automatically recognizes the calibration solution. If you use the calibration solution incorrectly or use a standard conductivity solution with a large deviation from the set value, the instrument will automatically alarm and displayERROR.
The instrument can perform some automatic calibration with standard conductivity solution. During calibration, the instrument automatically recognizes the calibration solution. If you use the calibration solution incorrectly or use a standard conductivity solution with a large deviation from the set value, the instrument will automatically alarm and displayERROR.
Automatic range conversion:
When measuring liquid conductivity, the instrument has an automatic range conversion function. When the conductive electrode is immersed in the sample liquid,DDS-307WThe instrument will automatically scan the current measurement value and convert the range, and display the endpoint measurement value at an appropriate resolution.
When measuring liquid conductivity, the instrument has an automatic range conversion function. When the conductive electrode is immersed in the sample liquid,DDS-307WThe instrument will automatically scan the current measurement value and convert the range, and display the endpoint measurement value at an appropriate resolution.
Temperature coefficient setting:
Solutions containing different ions often have different temperature coefficients, and accurately setting the temperature coefficient is crucial for precise measurement,DDS-307WCan be in0to3.9%Free setting within the range of each degree Celsius.
Solutions containing different ions often have different temperature coefficients, and accurately setting the temperature coefficient is crucial for precise measurement,DDS-307WCan be in0to3.9%Free setting within the range of each degree Celsius.
Electrode constant(K)set up:
When measuring high or low conductivity liquids, you need to choose conductivity electrodes with different constants. The instrument has three electrode constants to choose from(K=0.1,1,10)You can set it according to the selected electrode type, and the instrument will automatically convert the measured value.
When measuring high or low conductivity liquids, you need to choose conductivity electrodes with different constants. The instrument has three electrode constants to choose from(K=0.1,1,10)You can set it according to the selected electrode type, and the instrument will automatically convert the measured value.
LCD display screen:
The instrument is equipped with a customized LCD display screen, which is simple and bright. It not only displays measurement values clearly, but also has operation status icons, allowing you to have a quick understanding of the instrument's condition.
The instrument is equipped with a customized LCD display screen, which is simple and bright. It not only displays measurement values clearly, but also has operation status icons, allowing you to have a quick understanding of the instrument's condition.
Waterproof keyboard and electrode holder:
307WEquipped with waterproof panels, acid and alkali resistant, users do not have to worry about the sample solution spilling on the instrument and damaging it. The electrode holder that can be easily extended and retracted can be placed and stopped immediately, making it very convenient to use.
307WEquipped with waterproof panels, acid and alkali resistant, users do not have to worry about the sample solution spilling on the instrument and damaging it. The electrode holder that can be easily extended and retracted can be placed and stopped immediately, making it very convenient to use.
Microcomputer based conductivity meterTechnical parameters:
Conductivity measurement range:0~1.999,19.99,199.9,1999uS/cm,19.99,199.9mS/cm, Automatic6files
Conductivity measurement accuracy:±1% F.S
Instrument calibration point: Chinese version,1Point constant input; International version,1Point automatic calibration
Temperature compensation range:0~50℃
Temperature compensation method: manual
Temperature compensation coefficient:0~3.9%/℃
Optional electrode constant:0.1,1,10
Power type:DC9V/350mAPower adapter, use220V/50Hzpower supply
External dimensions:210(L)×205(W)×65(H)mm
Instrument weight:1.7kg
Conductivity measurement range:0~1.999,19.99,199.9,1999uS/cm,19.99,199.9mS/cm, Automatic6files
Conductivity measurement accuracy:±1% F.S
Instrument calibration point: Chinese version,1Point constant input; International version,1Point automatic calibration
Temperature compensation range:0~50℃
Temperature compensation method: manual
Temperature compensation coefficient:0~3.9%/℃
Optional electrode constant:0.1,1,10
Power type:DC9V/350mAPower adapter, use220V/50Hzpower supply
External dimensions:210(L)×205(W)×65(H)mm
Instrument weight:1.7kg
Instrument configuration:
Standard configuration:CON1type(K=1)Conductive electrode; Temperature probe; The power adapter
Optional configuration:CON0.1Type,CON10Type of conductive electrode
Standard configuration:CON1type(K=1)Conductive electrode; Temperature probe; The power adapter
Optional configuration:CON0.1Type,CON10Type of conductive electrode
Thank you for visiting us at Juneng Machinery【 http://bjch2012.wjw.cn/ 】If you have any questions You can call us and we will do our best to provide you with high-quality service.
Company Name: Beijing Jingcheng Huatai Instrument Co., Ltd
: Wang
:/ fifty-two million seven hundred and twenty-eight thousand one hundred and ten
: http://www.bjjcyb.com/
: bjjchtyb
More aboutConductivity meterPlease log inhttp://www.jcht2011.com/Related introduction,
Online inquiry