Portable transformer on-site calibrator
Portable transformer on-site calibrator
Product details



Selection instructions
RH2000A is equipped with a standard PT combination to form a portable complete set of current transformer calibration device;
RH2000V is equipped with a standard CT combination to form a portable complete set of current transformer calibration device.

Main indicators
In-phase component (%): 0.0001~± 20.00 resolution 0.0001,
Orthogonal component (fraction): 0.001~± 500 resolution 0.001,
Impedance (Ω): 0.0001~10.00 Resolution 0.0001,
Admittance (ms): 0.0001~12.00 resolution 0.0001.

Accuracy level
Level 1.0, Level 2.0

Main features
1. The host adopts a 320 × 240 dot matrix large screen LCD display with clear display, built-in long-life backlight illumination, full Chinese status display and operation prompts, and clear and beautiful fonts;
2. Can measure current transformers (CT), voltage transformers (PT), impedance (Z), admittance (Y);
3. Automatic measurement of voltage transformer errors (ratio difference, angle difference);

4. The dial gauge, angle difference, and ratio difference are displayed simultaneously, using a large dot matrix number, making the reading very intuitive;
5. Full point measurement can be carried out according to the measurement points required by the regulations, or by customizing the measurement points;
6. Can store 200 sets of measurement data and query calibration data in real time;
7. The resolution level can be automatically switched according to the size of the measurement data, or the measurement range can be manually selected as needed.
8. When the polarity is reversed, it will display the reversed polarity and have an audible alarm function;

9. The error data can be automatically adjusted according to the latest regulations based on the accuracy of the tested transformer;
10. It has an RS232 standard serial communication interface and can be connected to a computer to transfer data to data management software for computer management;
11. The instrument is small in size, light in weight, and easy to carry, making it very suitable for on-site calibration.


Technical indicators
1. Transformer calibrator
Working power supply: AC220V ± 10% 50 ± 0.5Hz
Accuracy level: 1.0 level, 2.0 level
Measurement range:
In-phase component (%): 0.0001~± 20.00 resolution 0.0001
Orthogonal component (min): 0.001~± 500 Resolution 0.001
Impedance (Ω): 0.0001~10.00 Resolution 0.0001
Admittance (ms): 0.0001~12.00 Resolution 0.0001
Workload: Current: T0 to Tx less than 0.1 Ω (cos Φ=1)
Voltage: less than 0.1VA (100V) between a and x
Working range: Current (A): 1% -130% In (In=5A) 5% -130% In (In=1A)
Voltage (V): 5% -150% Un (Un=100V, 100/√ 3V, 100/3)
5%-130%Un (Un =150V)
Polarity indication: current - more than 3% of the rated operating current, with polarity indication.
Voltage - More than 3% of the rated operating voltage, with polarity indication.
Power consumption:< 25VA harmonic suppression ratio:> 40db
Environmental conditions: Working temperature -5 ℃~+40 ℃ Relative humidity: ≤ 85% Altitude: < 1000 meters
Dimensions: 350 × 150 × 260 (mm) Weight: 6Kg

2. Current transformer device
Standard current transformers with different accuracies can be selected, and the measurement object is current transformers with a precision of 0.2 level or below;
One current measurement: 5A~1000A or 5A-2000A
Secondary current measurement: 5A (1A);
Accuracy level: 0.05S level, 0.02S level, 0.01S level
Test voltage: 500V
Transformer capacity: 5VA
Converter capacity: 7KVA
Dimensions: 470 × 320 × 460 (mm) Weight: 25Kg
Ordering notice: The primary current of standard current transformers can be extended to 2000A according to requirements;

3. Standard voltage mutual inductance
Standard voltage transformers with different accuracies can be selected, and the measurement object is voltage transformers with a precision of 0.2 level or below;
One voltage measurement: 6KV, 10KV, 35KV, 110/√ 3 KV
Secondary voltage measurement: 100V, 110/√ 3V
Accuracy levels: 0.05, 0.02, 0.01
Frequency: 50 ± 0.5Hz
Load: 0.2, 0.07VA
Voltage withstand: 20KV
Power factor: 1.0
Capacity of booster: 300VA
Ordering Notice: Standard voltage transformers can be configured individually according to voltage levels, or can be configured with multiple levels of taps.


Standard configuration details
Transformer calibrator host 1.0 level 2.0 level 1 unit
1) One set of current wires for one time
2) 1 set of secondary testing line
3) 1 set of standard attachments such as insurance pipes
4) 1 copy of product user manual
5) 1 copy of product factory inspection report
6) 1 copy of product qualification certificate
Details of selected accessories
1) RH2000A Type Configuration Details
Standard CT/Converter/CT Load Box
Standard CT 0.01S grade 0.05S grade 0.05S grade 5-1000A 5-2000A
2)RH2000VType configuration details
Standard PT/booster/PT load box
Standard PT 0.01 level, 0.02 level, 0.05 level
Standard PT 6KV 10KV 35KV 110/√ 3KV