HIAC PODS+Portable liquid particle counterCan provide real-time, proactive, and predictive maintenance information. Low viscosity or high viscosity fluids can be sampled and data reports can be provided according to ISO, NAS, ASTM, GOST, DEF, STAN, NAVAIR, or SAE standards. Intuitive, real-time, and reliable PODS+.
HIAC PODS+The functions and advantages of portable liquid particle counters
- Moisture detector
Reduce oxidation reactions in the system and extend its normal operating time.
- Bubble optimizer
By using a sealed pressurized chamber to reduce the influence of bubbles, accurate particle counting can be obtained.
- Sampling Plan Guide
A friendly navigation settings interface makes it easy to create custom test plans.
- Cleaning Procedure
Through intelligent self-cleaning programs, harmful particles are removed and sampling switching time is reduced.
- Self diagnostic warning
A continuous self diagnostic system that promptly reports sensor contamination and blockage to operators and issues maintenance requirements.
- Paperless homework
Built in data storage function, samples and reports can be backed up and exported to a computer or LIMS in a timely manner.
- Bottled sampling
Flexible sampling mode ensures that test operators can analyze liquid contamination anytime, anywhere.
- Online sampling
Connect with online operating systems through PODS+to detect the cleanliness of the system in real-time.
- 6-hour battery life
Equipped with high-performance lithium batteries, greatly increasing the instrument's battery life and making the operation configuration more flexible.
characteristic
- Customized sampling plan, sample testing runs in just 60 seconds
- Portable design, easy to transfer between different sampling points
- One click sampling, no need for training or professional instrument operation experience
- Instant on-site reporting, exempting laboratory waiting time and related fees
- Multiple liquid sampling capabilities (fuel, petroleum, water, and ethylene glycol)
- Can provide reports applicable to different cleanliness standards
- Detecting the moisture content of oil-based liquids
Product parameters
Number of channels | 9 |
Channel particle size | ISO-MTD: 4, 6, 10, 14, 21, 25, 30, 50, and 70 μ m ACFTD: 5, 10, 15, 20, 25, 30, 40, 50, and 100 μ m |
Flow rate | Fixed flow rates of 15, 30, and 50 mL/min |
Light source | 3B class laser, 775 to 810 nm, 5 mW (maximum value) |
Available calibration types |
|
Counting efficiency | JIS B9925:1997 |
Overlap loss error | 5%, 40000 particles/mL (based on ISO-11171:2010) |
Sample volume | 5 mL to 50 mL (programmable) |
Liquid temperature range | 0 ° C and 90 ° C (ambient temperature of 25 ° C) |
Viscosity range | 1 to 425 cSt, workshop air pressure of 100 PSI 1 to 150 cSt, built-in pump |
Immersion material | Stainless steel, chrome plated copper, sapphire, PEEK, PTFE, FFKM, and LDPE PODS+humidity sensors |
Reporting standards | ISO 4406:1999 NAS 1638 (ISO-MTD verification can be used when ACFTD verification is not available) SAE AS4059 NAVAIR 01-1A-17 (ISO-MTD verification can be used when ACFTD verification is not available) DEFSTAN 91-91 GOST 17216-2001 ASTM D7619-12 User specified Count/mL Original Count |
Data storage | 3000 records |
Dimensions (Depth x Width x Height) | 20.3 x 32.0 x 42.5 cm (8.0 x 12.62 x 16.75 in) |
Weight | PODS+:9.2 kg (20.1 lb) PODS+with humidity sensor: 9.6 kg (21.0 lb) |
Input/Output | Input: Ethernet 10/100M Bit, client, host USB port (USB 2.0), RS232 serial interface, and I/O port, suitable for pump control and alarm functions Output: USB interface, supports PDF and tsv format output, Ethernet and RS232 interfaces support custom Modbus protocol |
Sampling bottle operation | Sampling method: Pneumatic compression sample chamber Internal gas source: Internal compressor, up to 40 PSI (suitable for liquids with viscosity up to 150 cSt) External gas source: Clean Dry Gas (CDA) gas source, up to 110 PSI (suitable for liquids with viscosity exceeding 150 cSt) Rinse volume: 5 mL to 50 mL, with an increase of 1 mL |
Online operation | Sampling method: Online pressure adapter Liquid pressure: 40 to 5000 PSI Rinse volume: 5 mL to 999 mL, with an increase of 1 mL Sample quantity: 0 to 500 (programmable) Filter mode: Trigger alarm when running to dirty or clean pollution level |
Power supply | Rechargeable battery: lithium battery Battery usage time: 6 hours of continuous sampling with an interval of 3 minutes, including report printing time for each sample, as well as the time to collect 50 mL of sample at a rate of 50 mL/minute and discharge the volume of sample at a rate of 100 mL/minute. The above operations meet the calibration requirements of 5606 Battery charging time: 4 hours DC power input: 24 VDC, 2.5 A (maximum value) AC adapter: Universal 100-240 VAC, 50-60 Hz, 90 W |
Environmental conditions | Operating temperature range: 0 ° C to 50 ° C ambient temperature, external power (charging) temperature maximum is 40 ° C Storage temperature range:- 40 ° C to+70 ° C ambient temperature Relative humidity: 20% to 95%, non condensing Maximum usage altitude: 3000 meters (9842 feet) |
*This product is only used for scientific research and industry, not for clinical diagnosis.