Shanghai Yuyan Scientific Instrument Co., Ltd
Home>Products>Physiological signal telemetry system (heart rate, body temperature, activity level)
Firm Information
  • Transaction Level
    VIP member
  • Contact
  • Phone
    18502129044,15900559193
  • Address
    Room 301, Zhonghuan Science and Technology Park, No. 485 Xingmei Road, Minhang District, Shanghai
Contact Now
Physiological signal telemetry system (heart rate, body temperature, activity level)
The implantable physiological signal wireless telemetry system is used to measure physiological parameters such as heart rate, body temperature, and a
Product details

The implantable physiological signal wireless telemetry system is used for long-term measurement of various animals such as conscious and unrestrained rats, mice, rabbits, beagle dogs, monkeys, fish, etcheart rateBody temperature and activity levelWaiting for physiological parameters. The use of this system can ensure that animals can move freely in the cage without anesthesia or restraint, so that the measured physiological signals can better reflect the physiological conditions of animals in their natural state. Can be used for biological rhythm research and related vital sign monitoring.


The implantable physiological signal wireless telemetry system can wirelessly telemetry and record the heart rate, body temperature, and activity level of experimental animals


The implantable physiological signal wireless telemetry system consists of an implant (E-Mitt), a receiver, cables, and a VitalView recording and analysis computer. The 1-centimeter sized implant E-Mitt integrates sensors, amplifiers, and wireless signal transmitters, with multiple specifications depending on the measurement signal. The implantable E-Mitt repeater does not require a battery and is powered by a receiver. The experimenters buried the implant under the skin of the animal, and physiological signals were collected by the implant and converted into corresponding electrical signals, which were then transmitted wirelessly. The signals were received by the receiver under the feeding cage and transmitted to the data converter. After completing the data conversion, they were sent to the central processor for data processing. The system can connect up to 32 receivers simultaneously to complete large-scale experiments.


An E-Mitt is a miniature device implanted in an animal, which integrates sensors, amplifiers, digital conversion, wireless transmission functions, and solves the problem of anti rejection reactions in living organisms. Implants have specifications for measuring various parameters such as biological heart rate, body temperature, and activity level.

The main features of implantable physiological signal wireless telemetry system are:


Ø Wireless telemetry

Ø The implantable E-Mitt repeater does not have a battery

Long term monitoring - allows continuous and remote telemetry of experimental animals throughout their lives after implantation of the device

Accurate and reliable reporting of physiological and behavioral data of conscious and unrestrained animals



E-MitterMain technical parameters of the implant system:

E-Mitt temperature range

33° C - 41° C

E-Mitt accuracy

± 0.1° C

G2 E-Mitter size/weight Size/weight

15.5 mm x 6.5 mm/1.1 gm g

G2 HR E-meter Size/Weight Size/Weight

19.5 mm x 3.5mm mm/1.5 gm g

TA E-Mitter size/weight Size/weight

23 mm x 8 mm/1.6 gm grams

HR E-Mitter size/weight Size/weight

26 mm x 8 mm/2.2 gm grams

HR measuring range Heart rate measurement range

120 - 780 BPM

Activity activity volume

Gross motor activity only for gross motor activities


ER4000 signal receiver
ER4000 signal receiver, used to charge E-Mitters and receive measurement data transmitted back by E-Mitters. Suitable for standard feeding cages for large and small mice.

The signal receiver'sParameters

ER-4000Energizer/Receiver size 56 cm x 29 cm x 7 cm
Communication form RS 232 serial
Maximum number of excitation receivers 32
Single power supply supports the number of excited receivers 4
Stimulating the receiver requires space 30 cm (horizontal); 20 cm (vertical)
E-Mitt transmission range 12 cm above ER-4000

VitalView software

The excitation receiver and sensor are connected to the computer through VitalView software. Up to 240 data channels can be recorded, with a typical application of 120 test objects. For the E-meter system, a maximum of 32 test objects can be recorded.


VitalView software can set experimental parameters and collect data. Software management connects with hardware and stores basic graphical data analysis for display. The software also provides statistical data display and can output data.

Telemetry - used to monitor temperature, gross motor activity and heart rate data.
Physiological and behavioral monitoring oftransgenic mice and other laboratory animals has never been simpler. Through the use of biotelemetry and a variety of available sensors, it is possible for VitalView to monitor up to seven different physiological or behavioral parameters from a single laboratory subject

Combinations of the following parameters may be monitored for multiple laboratory subjects using VitalView:
Body Core Temperature
Heart Rate
Gross Motor Activity
Running Wheel Turns
Drinking/Licking Frequency
Feeding Behavior
Ambient Temperature
Ambient Light

E-Mitter Battery-Free Implantable Transponders:
Using telemetry to provide temperature, gross motor activity and heart rate data. An E-Mitter is a small implantable transponder that is powered by capturing energy from electrical fields generated by the ER-4000 Energizer/Receiver. This allows the E-Mitter to operate without batteries and remain implanted indefinitely to monitor the subject''s temperature, activity or heart rate. As a result, high costs and downtime of explantation, refurbishment and reimplantation are avoided.


If only the core body temperature of rats and mice needs to be measured, implantable temperature capsules can be selected to remotely measure the body temperature data:


reference:

1.Ganeshan, Kirthana et al. “Energetic Trade-Offs and Hypometabolic States Promote Disease Tolerance.” Cell vol. 177,2 (2019): 399-413.e12. doi:10.1016/j.cell.2019.01.050
2.Li, Yongguo et al. “Secretin-Activated Brown Fat Mediates Prandial Thermogenesis to Induce Satiation.” Cell vol. 175,6 (2018): 1561-1574.e12. doi:10.1016/j.cell.2018.10.016
3.Dodd, Garron T et al. “Leptin and insulin act on POMC neurons to promote the browning of white fat.” Cell vol. 160,1-2 (2015): 88-104. doi:10.1016/j.cell.2014.12.022
4.Piñol, Ramón A et al. “Brs3 neurons in the mouse dorsomedial hypothalamus regulate body temperature, energy expenditure, and heart rate, but not food intake.” Nature neuroscience vol. 21,11 (2018): 1530-1540. doi:10.1038/s41593-018-0249-3
5.Li, Jin et al. “Neurotensin is an anti-thermogenic peptide produced by lymphatic endothelial cells.” Cell metabolism vol. 33,7 (2021): 1449-1465.e6. doi:10.1016/j.cmet.2021.04.019
6.Piñol, Ramón A et al. “Preoptic BRS3 neurons increase body temperature and heart rate via multiple pathways.” Cell metabolism vol. 33,7 (2021): 1389-1403.e6. doi:10.1016/j.cmet.2021.05.001
7.Krisko, Tibor I et al. “Dissociation of Adaptive Thermogenesis from Glucose Homeostasis in Microbiome-Deficient Mice.” Cell metabolism vol. 31,3 (2020): 592-604.e9. doi:10.1016/j.cmet.2020.01.012
8.Sustarsic, Elahu G et al. “Cardiolipin Synthesis in Brown and Beige Fat Mitochondria Is Essential for Systemic Energy Homeostasis.” Cell metabolism vol. 28,1 (2018): 159-174.e11. doi:10.1016/j.cmet.2018.05.003
9.Heine, Markus et al. “Lipolysis Triggers a Systemic Insulin Response Essential for Efficient Energy Replenishment of Activated Brown Adipose Tissue in Mice.” Cell metabolism vol. 28,4 (2018): 644-655.e4. doi:10.1016/j.cmet.2018.06.020
10.Dodd, Garron T et al. “A Hypothalamic Phosphatase Switch Coordinates Energy Expenditure with Feeding.” Cell metabolism vol. 26,2 (2017): 375-393.e7. doi:10.1016/j.cmet.2017.07.013
11.Keipert, Susanne et al. “Long-Term Cold Adaptation Does Not Require FGF21 or UCP1.” Cell metabolism vol. 26,2 (2017): 437-446.e5. doi:10.1016/j.cmet.2017.07.016
12.Wang, Tongfei A et al. “Thermoregulation via Temperature-Dependent PGD2 Production in Mouse Preoptic Area.” Neuron vol. 103,2 (2019): 309-322.e7. doi:10.1016/j.neuron.2019.04.035
13.Chavan, Rohit et al. “Liver-derived ketone bodies are necessary for food anticipation.” Nature communications vol. 7 10580. 3 Feb. 2016, doi:10.1038/ncomms10580
14.Jiang, Lin et al. “Leptin receptor-expressing neuron Sh2b1 supports sympathetic nervous system and protects against obesity and metabolic disease.” Nature communications vol. 11,1 1517. 23 Mar. 2020, doi:10.1038/s41467-020-15328-3
15.Walker, William H 2nd et al. “Acute exposure to low-level light at night is sufficient to induce neurological changes and depressive-like behavior.” Molecular psychiatry vol. 25,5 (2020): 1080-1093. doi:10.1038/s41380-019-0430-4
16.Zhang, Xue-Ying et al. “Huddling remodels gut microbiota to reduce energy requirements in a small mammal species during cold exposure.” Microbiome vol. 6,1 103. 8 Jun. 2018, doi:10.1186/s40168-018-0473-9
17.Ingiosi, Ashley M et al. “A Role for Astroglial Calcium in Mammalian Sleep and Sleep Regulation.” Current biology : CB vol. 30,22 (2020): 4373-4383.e7. doi:10.1016/j.cub.2020.08.052
18.Padilla, Stephanie L et al. “Kisspeptin Neurons in the Arcuate Nucleus of the Hypothalamus Orchestrate Circadian Rhythms and Metabolism.” Current biology : CB vol. 29,4 (2019): 592-604.e4. doi:10.1016/j.cub.2019.01.022




:,

yuyanbio

: yuyanbio

Online inquiry
  • Contacts
  • Company
  • Telephone
  • Email
  • WeChat
  • Verification Code
  • Message Content

Successful operation!

Successful operation!