Ø Easy to operate: direct injection without pre-treatment;
Ø Efficient: The enterprise has its own testing equipment, which can detect incoming materials, semi-finished products, and raw materials at any time without waiting for inspection within 7 working days,;
Ø Environmental Protection: No need for reagents, no need for environmental impact assessment;
Ø Quick:Rapid sample testing for 20 minutes per sample;
Ø No need for a professional laboratory;
Ø Economics;
serial number |
description |
quantity |
unit |
1 |
Gas chromatograph host |
1 |
Taiwan |
2 |
Split capillary column injection port |
1 |
set |
3 |
Air generator |
1 |
Taiwan |
4 |
hydrogen generator |
1 |
Taiwan |
5 |
Chromatography qualitative and quantitative analysis software |
1 |
set |
6 |
chromatographic column |
1 |
root |
Laboratory supporting equipment:
serial number |
description |
quantity |
unit |
1 |
Nitrogen cylinder (40L)+pressure reducing valve |
1 |
set |
2 |
gas cylinder cabinet |
1 |
a |
3 |
One ten thousandth electronic balance |
1 |
Taiwan |
4 |
refrigerator |
1 |
Taiwan |
5 |
Computer, color inkjet printer |
1 |
set |
serial number |
description |
quantity |
unit |
1 |
Thermal cracking/desorption instrument |
1 |
Taiwan |
3 |
Quartz cracking furnace |
2 |
a |
4 |
Quartz injection tube (large tube) |
5 |
a |
5 |
Quartz sample boat (small tube) |
200 |
a |
6 |
Sample injection needle # 7 |
3 |
a |
7 |
Tool kit (wrench, screwdriver, connecting wire, sealing ring, graphite pad, trachea, etc.) |
1 |
set |
|
Supporting sample processing tools | ||
1 |
Tweezers, carving knife, diagonal pliers (for disassembling samples), spray gun, weighing paper, 35mm glass culture dish (for weighing), cushion plate, 10MLInjection needle, 50mL beaker (used to hold the sample boat after use) |
matching |
Standard product:
serial number |
description |
quantity |
unit |
1 |
1000ppmPhthalate ester mixed standard solution 4P |
1 |
bottle |
Py/TD section (fully meets the requirements of IEC62321-8:2017): | |
project |
performance metrics |
Thermal cracking/desorption temperature range |
5 ℃ -500 ℃ above room temperature |
temperature control accuracy |
For the target compound, the temperature control accuracy is ± 0.2 ℃ |
heating rate |
≤200℃/min |
Analyze temperature control |
Program temperature control |
purge flow |
0-500mL/min |
Interface temperature range |
5 ℃ -400 ℃ above room temperature |
GC section: | |
Injection port parameters |
l 0~1000 mL/min (helium) 0-200 mL/min (nitrogen) l Flow setting accuracy: 0.001 mL/min l Program boost/boost current: 5th order l Gas control methods: constant pressure, constant flow, program up/down pressure, program up/down flow |
Column temperature box parameters |
l Operating temperature range: 5 ℃ to 450 ℃ above room temperature; l Programmable temperature rise: 30 levels, 31 platforms l Temperature control accuracy: 0.1 ℃ l Independent small column box heating zone can be set l Automatic protection function with column box temperature |
Detector parameters |
l Hydrogen flame ionization detector (FID) l High precision electronic flow/pressure control l Data collection frequency: up to 500Hz |
Chromatography Workstation |
l Support Windows 7/10, 32-bit bitmap user interface (including user assistant and other functions) l It can quickly set various parameters such as front and rear injection ports, front and rear detectors, column temperature box heating program, chromatographic column conditions, and valve events l It has powerful application functions such as double click automatic recognition of chromatographic peak retention time, multi spectrum comparison and repeatability analysis, automatic sampler sequence acquisition, automatic integration correction, and output report l Peak integration processing function, qualitative function (supporting multiple relative retention times, grouping), quantitative function (area percentage method, corrected area percentage method, internal standard method, external standard method), calibration point and level number, manual creation of working curve function, chromatographic column performance calculation, data comparison function l GCAutomatic stop/start, system confirmation (GC self diagnosis), function, status recording function l Available in both Chinese and English l Can perform snapshot function during the analysis process l The report directly displays the test results without the need for manual editing |
This method is used to analyze the phthalates restricted by the RoHS directive (IEC 62321-8:2017) for the regulation of electronic and electrical products.
Py/TD-GCAs an alternative solutionAfter extensive testing, it can meet the screening requirements for RoHS 2.0 ortho benzene.