PPM-800 formaldehyde analyzer
PPM-800 formaldehyde analyzer
Product details

PPM-800 formaldehyde analyzer

Formaldehyde analyzerAccording to the national standard GB50325-2010 for indoor air quality, a unique three-level sensor is used, with a highly sensitive electrode electrochemical formaldehyde sensor as the detection unit, to detect the very low volatile formaldehyde 77 in indoor air. When the detected formaldehyde is sucked in by the air pump and comes into contact with the sensor storage chamber and the sensitive electrode of the electrochemical sensor, an electrochemical reaction occurs, which outputs a stable electrical signal. The electrical signal is processed by the central processor and the gas concentration value can be accurately displayed on the LCD screen in numbers. The sensitivity of its detection will be 20-100 times greater than that of diffusive sensors.

It can be widely used in indoor environment formaldehyde detection, environmental decoration, scientific research and teaching, environmental monitoring departments, and specialized equipment for formaldehyde detection in inspection and quarantine.

2、 Product parameters

1. Detection principle: electrochemical sensor

2. Testing method: pump suction

3. Detection range: 0-19.99PPM

4. Resolution: 0.01

5. * Small detection: 0.01PPM

6. Display mode: digital LCD display

7. Responsiveness:< 10S

8. Zero drift: ± 1% F.S

9. Power supply: Lithium ion rechargeable battery

10. Dimensions: 205 × 95 × 95mm

11. Weight: 0.68kg

3、 Product Features

1. The sensitivity of electrochemical sensors is 20-100 times higher than that of diffusive sensors; Can detect lower concentrations of formaldehyde molecules;

2. Electrochemical sensors are unique two electrode sensors that do not require independent reference voltages or battery power supply;

3. Using DC7.2V1800mA high-capacity lithium-ion rechargeable battery, it can measure continuously 50 times;

4. Electrochemical sensors have an ultra long service life of over 5 years;

5. The instrument automatically monitors the capacity of lithium-ion batteries during operation to prevent over discharge of the batteries;

Guidelines for Purchasing Indoor Air Quality TestersWith the widespread use of home decoration, the concentration of indoor pollutants is increasing, affecting people's health. In order to standardize the quality of various materials and protect people's health, the country has introduced a series of indicators to propose restrictions:

type

parameter

formaldehyde

≤0.08mg/m3

benzene

≤0.09mg/m3

ammonia

≤0.2mg/m3

TVOC

≤0.5mg/m3

1、 Formaldehyde detector
Indoor formaldehyde detectors are divided into two types: imported and domestically produced:

category

model

range

introduce

Formaldehyde detector

4160-II

0-19.99ppm

The assembled version 4160-2 has precise testing and can be certified by the National Institute of Metrology.

PPM-800II

0-19.99ppm

Specially customized according to the 4160-2 range parameters, with simple operation and accurate values, suitable for third-party testing units such as environmental protection bureaus

Imported formaldehyde detector

Interscan4160-2, USA

0-19.99ppm

The domestic promotion and recognition are very high, and various industries are quite recognized

UK PPM-HTV/HTV-M

0-10ppm/0-30ppm

Convenient to carry, easy to operate, precise in numerical values, it belongs to the high cost-effective imported products

2、 Multi functional air quality detector
This is a powerful ten in one indoor air quality detector independently developed by our company, which can simultaneously detect parameters such as formaldehyde, benzene, ammonia, toluene, xylene, TVOC, etc. It is suitable for the testing industry and various environmental protection bureaus, with very high price and quality.

type

measuring range

formaldehyde

0.01-1.2mg/m3

benzene

0.01-4mg/m3

ammonia

0.01-3mg/m3

toluene

0.01-4mg/m3

xylene

0.01-4mg/m3

TVOC

0.01-4mg/m3

Conventional gas types and parameters (gas types, ranges, and resolutions not listed can be customized by phone)



The measurement range of the tested gas can be selected with range resolution and response time

Flammable gas (EX)

0-100%LEL

0-100%VOL

0.1%LEL/0.1%VOL

≤10S

Oxygen (O2)

0-30%VOL

0-25%VOL

0.01%VOL

≤10S

Carbon monoxide (CO)

0-1000ppm

0-2000ppm

0.1ppm/1ppm

≤10S

Hydrogen sulfide (H2S)

0-100ppm

0-1000ppm

0.01ppm/0.1ppm

≤10S

Ammonia (NH3)

0-100ppm

0-200ppm

0.01ppm/0.1ppm

≤10S

Chlorine gas (CL2)

0-10ppm

0-100ppm

0.01ppm/0.1ppm

≤10S

Hydrogen chloride (HCL)

0-20ppm

0-100ppm

0.01ppm/0.1ppm

≤10S

Nitric oxide (NO)

0-100ppm

0-250ppm

0.01ppm/0.1ppm

≤10S

Nitrogen dioxide (NO2)

0-20ppm

0-100ppm

0.01ppm/0.1ppm

≤10S

Formaldehyde (CH2O)

0-10ppm

0-50ppm

0.01ppm/0.1ppm

≤10S

Ozone (O3)

0-10ppm

0-100ppm

0.01ppm/0.1ppm

≤10S

Carbon dioxide (CO2)

0-2000ppm

0-100%VOL

1ppm/0.01%VOL

≤10S

JG3000 series gas selection table

Gas type and molecular formula

Optional range (range not listed can be customized by phone); The letter 'Chang' indicates the standard range

CO Carbon Monoxide

0-50, 100, 200, 500, 1000 (normal), 2000, 5000ppm

H2S hydrogen sulfide

0-10, 20, 50, 100, (normal), 200, 0-500, 1000, 2000ppm

O2 oxygen

0-5%, 25%, 30% (Regular), 50% VOL

EX may have natural gas

0-100% LEL (normal)

N2 nitrogen gas

0-100%. Vol (often)

NH3 ammonia gas

0-50, 100ppm (normal), 200, 500, 1000, 2000, 5000ppm

CL2 chlorine gas

0-10 (normal), 20, 50, 100, 200, 500 ppm

VOC Total Volatile Organic Gas Detector

0-2、10、50、100、200、1000、2000、6000、10000PPM

H2 hydrogen gas

0-500, 1000 (normal), 2000, 5000, 10000, 20000, 40000 ppm

CH2O formaldehyde

0-10 (normal), 20, 50, 100, 500, 1000ppm

O3 ozone

0-1, 5, 10, 20, 50 (normal), 100, 200, 500, 1000ppm

CO2 carbon dioxide (infrared)

0-1000, 2000 (normal), 5000, 10000, 50000ppm

CO2 carbon dioxide (infrared)

0-10%、20%、50%、100%Vol

NO nitric oxide

0-100, 0-250 (normal), 500, 1000, 2000, 4000ppm

NO2 Nitrogen dioxide

0-20 (normal), 50, 100, 500, 1000, 2000, 4000ppm

NOX nitrogen oxides

0-20 (normal), 50, 100, 500, 1000, 2000, 4000ppm

SO2, sulfur dioxide

0-10, 20, 100 (normal), 150ppm, 200, 1000, 2000 ppm

ETO epoxyethane

0-10 (normal), 20, 50, 100ppm

Ethylene oxide ETO

0-500、1000ppm

PH3 phosphine

0-10 (normal), 20, 50, 100, 1000, 2000, 3000, 5000ppm

HCL hydrogen chloride

0-10 (normal), 20, 50, 100ppm

HCN hydrogen cyanide

0-10 (normal), 20, 50, 100ppm

COCL2 phosgene

0-1ppm (normal)

CLO2 chlorine dioxide

0-1, 10 (normal), 20, 50ppm

SiH4 silane

0-10, 50ppm (normal)

F2 fluorine gas

0-1 (normal), 10ppm

HF hydrogen fluoride

0-10 (normal), 50ppm

HBr hydrogen bromide

0-10, 50 (normal), 100ppm

B2H6 diborane

0-5, 10, 50ppm (normal)

AsH3 arsine

0-1, 10 (normal), 50ppm

GeH4 Germanane

0-1ppm (normal)

N2H4 hydrazine, hydrazine

0-1ppm (normal)

THT tetrahydrothiophene

0-100ppm, 0-50mg/m3 (normal), 0-100mg/m3

Br2 bromine gas

0-5, 10 (normal), 50ppm

C2H2 acetylene

0-100ppm (normal)

CS2 carbon disulfide

0-100% LEL, 50ppm (normal)

C3H3N acrylonitrile

0-10, 20 (normal), 50, 100ppm

CH3COOH ethyl acetate

0-10、20p、 50, 100 (normal), 500, 1000ppm

C2H4 ethylene

0-10 (normal), 20, 50, 100, 500, 1000ppm

CH3OH methanol

0-50, 100 (normal), 500, 1000ppm

C2H5OH ethanol

0-10, 50, 100 (normal), 500, 1000ppm

CH4S Methyl Thiol

0-20 (normal), 50ppm

C2H3Cl vinyl chloride

0-50, 100ppm (usual)

Chloromethane (monochloromethane, dichloromethane, etc.)

0-50, 100ppm

C8H8 styrene (electrochemical)

0-50, 200, 1000, 10000ppm

Styrene (PID)

0-100 (normal), 200, 1000, 6000ppm

Total volatile organic compounds (TVOC) PID

0-1, 10, 50PPM, (high precision, high resolution 0.001PPM)

Total volatile organic compounds (TVOC) PID

0-100 (normal), 2001000, 6000, 10000ppm

Bromomethane (CH3Br) (PID photoionization)

0-100 (normal), 2001000, 10000PPM

Bromomethane (CH3Br) (electrochemical)

0-50100 (normal), 2001000ppm

C6H6 benzene (PID photoionization)

0-1, 10, 50PPM (high precision, high resolution 0.001PPM)

C6H6 benzene (PID photoionization)

0-100 (normal), 2001000, 600010000ppm

Toluene (PID photoionization)

0-1, 10, 50PPM (high precision, high resolution 0.001PPM)

Toluene (PID photoionization)

0-100 (normal), 200,1000, 6000, 10000ppm

Xylene (PID photoionization)

0-1, 10, 50PPM (high precision, high resolution 0.001PPM)

Xylene (PID photoionization principle)

0-100 (normal), 2001000, 600010000ppm

Total volatile organic compounds (TVOC) electrochemistry

0-10,50,100PPM

C6H6 benzene (electrochemical)

0-10,50,100PPM

Toluene (electrochemical)

0-10,50,100PPM

Xylene (electrochemical)

0-10,50,100PPM

The ranges listed in the above table are conventional ranges and are not included in the list. If you need to test, please consult our sales personnel

Jinggong Instrument provides you with comprehensive technical support and after-sales service! Details consultation: WeChat Same Account




Online inquiry
  • Contacts
  • Company
  • Telephone
  • Email
  • WeChat
  • Verification Code
  • Message Content

Successful operation!

Successful operation!

Successful operation!