Product Features
★ More powerful data processing capabilities, which can automatically draw data curves for generating historical measurements.
★ Adopting a multi-channel selection liquid extraction device imported from abroad ensures high repeatability and accuracy of measurement.
★ It can realize user reverse control platform. After installing device control software (optional) on the computer, users can control and test the instrument on the computer.
★ It has printing function and can be connected to a printer (optional) to print the measured data in a timely manner.
★ Equipped with a 7-inch touch screen and a simple operating interface, it can be easy for users to learn, operate, and maintain.
★ With a large data storage capacity, it enables the preservation of historical data for no less than 1 year (with a measurement interval of 1 time/2 hours). Greatly meeting the needs of customers.
★ Automatic liquid leakage alarm function, when a reagent leakage occurs, the instrument will automatically alarm and prompt the user to perform maintenance.
The quantitative measurement adopts signal automatic recognition function, ensuring high accuracy and repeatability of the measurement.
The maintenance of chemical reagents is simplified and convenient, with a monthly replacement of reagents, greatly reducing the maintenance workload for users.
The pre-treatment adopts a pipeline type to ensure the authenticity of the water sample, ensuring that the sampling is not blocked and easy to adjust.
★ One click upgrade of USB flash drive makes software updates easier.
project |
Specifications |
project |
Specifications |
test method |
Xylenol Orange Optical Colorimetric Method |
self check |
Self-monitoring of leaks; Instrument status self diagnosis |
test scope |
(0~10)mg/L |
analog output |
1 channel 0/4-20mA (expandable to 2 channels) |
accuracy |
±10% |
reproducibility |
Better than 8% |
data communication |
RS485、RS232 |
instrument calibration |
automatic |
digestion time |
5min, Can be set arbitrarily |
data storage |
Can save data for more than 1 year (measurement interval of times/2 hours) |
Reagent consumption |
1 month (reagents and standard solutions) |
Sample pH |
5~10 |
Monitoring mode |
Continuous monitoring, timed measurement, manual arbitrary measurement |
Dissolving temperature |
110℃ |
Correction interval |
Any setting |
Operating Temperature |
+5~+40℃ |
Cleaning interval |
Any setting |
power supply |
(220±10%)VAC; (50-60)Hz |
maintenance cycle |
Maintenance interval>6 months, next about 30 minutes |
power consumption |
Less than 100VA |
MTBF |
>720h/time |
|
|