The OXYMAT 61 gas analyzer operates based on the principle of paramagnetic pressure changes and can be used to measure oxygen in gases. The original imported price is good.

Shenzhen Xiangzhuyuan Industrial Co., Ltd. mainly produces Siemens series, EBM fans, Xerox fans, Heidenhain encoders, as well as various well-known industrial control new products in Europe. Please feel free to contact me at any time if you need.

Commonly used items are available in large quantities in stock, and if there are advantages, please feel free to inquire. Our company will provide you with the best products and the best pre-sales and after-sales services.QQ: / /

Main technical features and performance:

LCD display screen, full range setting, zero suppression, pressure correction capability, 19 inch disc mounting.

Minimum measurement range: 2%

Maximum measurement range: 100%

Zero drift:<0.5%/month

Measurement drift:<0.5%/month

Power supply: 200-240V AC, 48-63HZ

Output signal: 0/2/4-20mA

Load: 750 Ω

Application examples

Measurement of O 2

Boiler control in combustion factories

? Safety related fields

As a reference variable for statutory flue gas emissions

Automotive industry (test bench system)

Packaging industry

Alarm device

In chemical plants

Quality monitoring of high-purity gases

Special characteristics

Four freely programmable ranges with zero suppression; All ranges are linear

The signal output range of electrical isolation is 0/2/4-20 mA (can also be negative)

Automatic range switching, remote range switching, or manual range selection is also available

Measurement values can be stored during the calibration process of the analyzer

The time constant can be selected within a wide range (static/dynamic noise suppression); For example, the response time of each component can be matched with its respective application

The menu operation is simple and easy

Short response time

Long term drift is small

Supply reference gas through external gas (N2, O2 or air, pressure approximately 3000hPa) or built-in reference air pump (ambient air)

The setting of two-level access passwords can prevent unintentional and unauthorized personnel from entering

The internal pressure sensor is used to calibrate the fluctuation of sample gas pressure within the range of 700-1200 hPa (absolute pressure)

Parameterized automatic range switching calibration

Recommended operating methods based on NAMUR

Fieldbus connection (optional)

Sample gas monitoring (optional)

When the reference gas is connected at a pressure of 3000-4000 hPa

Reference gas monitoring

The minimum range varies depending on the analyzer model (% 2.0 or% 5.0 O2)

Customer specific analyzer options, such as:

-Customer acceptance

-TAG tag

-Drift record

Because the electrical connection can be easily removed from the analyzer, it is also easy to replace the analyzer

A 19 "rack with 4 HU can be installed on a hinged frame

A 19 "rack with 4 HU can be installed in a cabinet, with or without sliding rails

The front panel can be removed for maintenance of the analyzer (connected to a laptop)

Internal gas path: FKM (Viton) pipeline sample gas connection: pipeline diameter of 6 mm or 1/4 '

The sample chamber is made of stainless steel (material number. 1.4571)

OXYMAT 61 Oxygen Analyzer 7MB2001-0CA00

OXYMAT 61 Oxygen Analyzer 7MB2001-1CA00

OXYMAT 61 Oxygen Analyzer 7MB2001-0DA00

OXYMAT 61 Oxygen Analyzer 7MB2001-1DA00

OXYMAT 61 Oxygen Analyzer 7MB2001-0EA00

OXYMAT 61 Oxygen Analyzer 7MB2001-1EA00

OXYMAT 61 Oxygen Analyzer 7MB2001-0FA00

OXYMAT 61 Oxygen Analyzer 7MB2001-1FA00

Parts Listing

Part Number Name Order Number Remarks

O1.1 Analysis component, material number 1.4571 C79451-A3460-B31 without flow compensation edge

O1.2 Measuring head C79451-A3460-B525 without flow compensation edge

O1.2.1 O-ring C79121-Z100-A32 1 set

O1.3 Sampling unit, material number 1.4571 C79451-A3277-B535 without flow compensation edge

O1.4 Magnetic Connection Panel C79451-A3474-B606

O1.5 O-ring, FKM (VITON) C71121-Z100-A159 1 set

O2.1

Motherboard C79451-A3480-D501 motherboard a. firmware; German language

C79451-A3480-D502 motherboard a. firmware; English

C79451-A3480-D503 motherboard a. firmware; French

C79451-A3480-D504 motherboard a. firmware; SPANISH

C79451-A3480-D505 motherboard a. firmware; ITALIANO

O2.1.1 Motherboard C79451-A3474-B601 without firmware

Shenzhen Xiangzhuyuan Industrial Co., Ltd. mainly produces Siemens series, EBM fans, Xerox fans, Heidenhain encoders, as well as various well-known industrial control new products in Europe. Please feel free to contact me at any time if you need.

Commonly used items are available in large quantities in stock, and if there are advantages, please feel free to inquire. Our company will provide you with the best products and the best pre-sales and after-sales services.QQ: / /

Online inquiry
  • Contacts
  • Company
  • Telephone
  • Email
  • WeChat
  • Verification Code
  • Message Content

Successful operation!

Successful operation!

Successful operation!