The medical device gas chromatograph adaptation host mainly includes: host, detector, chromatographic column, workstation, certificate of conformity,
Product details

Medical device gas chromatographdetailed description

project

description

quantity

Gas chromatograph host

Chromatograph host+gas path control system+injection system+amplification circuit control+CPU control system+host fault diagnosis, audio-visual Chinese display+dual output system

1 set

detector

Detector for residual ethylene oxide

1 piece

chromatographic column

Specialized chromatographic column

1 piece

Headspace bottle

Suitable for detecting residual ethylene oxide

Workstation system

Dual channel multifunctional workstation+random accessories

+Computer

+Printer

1 set

Gas source

Air generator

Hydrogen generator

High purity nitrogen gas cylinder

Each 1

Accessories package

Medical device gas chromatographAdaptation host, mainly including:; Certificate of conformity, instruction manual, microinjector, gas tube, soap bubble flowmeter, connector, stainless steel tube, etc

1 set

Automatic headspace sampler

(Optional accessories)

Mainly used to improve the accuracy of detecting residual substances in solvents. If not purchased, use the headspace bottle provided by our company to comply with national standards

1 set

Temperature control indicators:
1) Column box: Room temperature+5 ℃ -400 ℃ Accuracy: 0.1 ℃ Display accuracy up to 0.01 ℃
2) Injector: Room temperature+5 ℃ -400 ℃ Accuracy: 0.1 ℃ Display accuracy up to 0.01 ℃
3) Detector: Room temperature+5 ℃ -400 ℃ Accuracy: 0.1 ℃ Display accuracy up to 0.01 ℃
4) Column temperature box volume: 248 * 248 * 260MM
5) Program temperature rise order: fifth order linear range rise
6) Program heating rate: 0.1 ℃~40 ℃ (increments of 0.1 ℃)
7) Constant temperature holding time for each stage: 0~9999.9min (increments of 0.1min)

Technical specifications of detector:

detector

Sensitivity/Sensitivity

noise

drift

linear

characteristic

FID

Mf≤1×10-11G/s (benzene)

≤ 0.02mV

≤ 0.15mV/h

≥107

Circular collection electrode, corundum ceramic nozzle

TCD

S ≥ 3000mV. ml/mg (benzene)

≤ 0.02mV

≤ 0.15mV/h

≥105

Imported rhenium tungsten wire, constant current power supply

Note: External dimensions:660 * 460 * 465mm Machine weight: 60 kg Input power supply: AC 220V ± 10% 50HZ 2KW

Each instrument can be configured with up to 3 types of detectors, and an additional 2 types of arbitrary detectors can be added