Main technical performance of YWK-50-C: Environmental temperature:- 25~55℃ Shell protection level: YWK-50-C IP44 Anti vibration performance: YWK-50-C 2~25Hz 1.6mm 25~100Hz 40m/s2 |
Contact capacity: AC380V 3A (resistive) DC220V 2.5A (resistive) Repetitive error: see specification table Mechanical lifespan: 105order |
|
|
YWK-50-C specification | ||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
Switching difference adjustable | ||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
|
||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
|
||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
Adjustment of YWK-50-C setting value: |
The steps for adjusting the set value of the pressure controller are illustrated as follows: [Example]: Select a pressure controller with a specification of 0-0.8MPa, and require the output pressure of the gas compressor to be maintained between 0.5-0.6MPa. The specific operating steps are as follows: Connect the switch terminal of the controller to the power control circuit of the compressor motor (connect terminal 1.3 for voltage reduction and disconnect for voltage boost). Introduce the controlled gas into the bellows chamber of the controller. Rotate the set value adjustment lever to make the pointer indicate 0.5 MPa on the scale scale, which is the lower switching value. Connect the power supply to activate the compressor and increase the gas pressure. Repeatedly adjust the switching knob to switch the controller switch when the pressure rises to 0.6 MPa (upper switching value). |
|
YWK-50-C appearance and installation dimensions: | |
Pressure controllers with specifications 1 and 2 |
Pressure controllers with specifications 3-11 |
|
|
YWK-50-C installation: | |
Open the watch cover and install the controller vertically on the dashboard. It is strictly prohibited to manually move or use tools to collide with the arm to prevent changes in performance. |
|
YWK-50-C pressure controller pressure pipe connection diagram |
|
Recheck if the installation is properly cut, install the meter cover, and turn on the power. According to the usage of the controller, regular calibration should be carried out. | |
|
Process of action of single pole double throw micro switch: Terminal 1-3: Connect when the pressure drops to the lower switching value. Terminal 1-2: Open when the pressure drops to the lower switching value. Cable:φ12 marine orφ7.5 Three core. |
|
|
Precautions for YWK-50-C: |
The indicator value of the controller pointer is the down switch value, and the adjustment range of the set value is the adjustment range of the down switch value. |