Manufacturer of Transformer Comprehensive Tester - Winding Deformation Monitoring Instrument for Transformer Monitoring in Thermal Power Plants
The XW-800A+transformer winding deformation tester is used to test power transformers with voltage levels of 6kV and above, as well as other special p
Product details
productdetails

PRODUCT DETAILS

The XW-800A+transformer winding deformation tester is used to test power transformers with voltage levels of 6kV and above, as well as other special purpose transformers. During operation or transportation, power transformers inevitably suffer from various short-circuit currents or physical impacts. Under the strong electric force generated by short-circuit currents, the transformer windings may lose stability, leading to local distortion, bulging, or displacement deformation phenomena, which will seriously affect the operation of transformers. According to the national power industry standard DL/T911-2004, the frequency response analysis method is used to measure the deformation of transformer windings. This is achieved by detecting the amplitude frequency response characteristics of each winding of the transformer and comparing the detection results vertically or horizontally. Based on the degree of change in the amplitude frequency response characteristics, the possible deformation of the transformer windings can be determined.

1、 Main technical features of portable transformer winding deformation frequency response tester


Using the sweep frequency method to measure the characteristics of transformer windings, without lifting or disassembling the transformer cover, by detecting the amplitude frequency response characteristics of each winding, the distortion, bulging, or displacement of the windings can be accurately measured for transformers of 6kV and above.


The measurement speed is fast, and the measurement time for a single winding is within 1-2 minutes.


The frequency accuracy is very high, with high precision.


Digital frequency synthesis provides higher frequency stability.


5000V voltage isolation, sufficient protection for testing computers.


L can load 9 curves simultaneously, and the relevant parameters of each curve are automatically calculated to diagnose the deformation of the winding and provide reference conclusions for diagnosis.


The analysis software has powerful functions, and the software and hardware indicators meet the DL/T911-2004 standard.


The software management is highly user-friendly and intelligent. After setting the parameters, all measurement work can be completed with just one key press.


The software interface is simple and intuitive, with clear menus for analysis, storage, report export, printing, and more.

2、 Main technical specifications of portable transformer winding deformation frequency response tester


Measurement speed: 1 minute to 2 minutes for single-phase winding


Output voltage: Vpp-25V, Automatic adjustment during testing


Output impedance: 50 Ω


Input impedance: 1M Ω (with a built-in 50 Ω matching resistor in the response channel)


Sweep frequency range: 100Hz-2MHz


Frequency accuracy: 0.001 percentage


Sweep frequency method: linear or logarithmic, sweep frequency interval and number of points can be set arbitrarily


L curve display: amplitude frequency curve (phase frequency curve, optional)


Wide measurement dynamic range: - 120dB~20dB


Power supply voltage: AC220V ± 10%, external power adapter, host power supply: DC12V


Host weight: 1.8kg

3、 Main features of the portable transformer winding deformation frequency response testing instrument testing and analysis software


Using the Windows platform, compatible with Windows 2000/Windows XP/Windows 7/Windows 8.


Using a database to store test data, the management of test data is simple and convenient.


L can load 9 curves simultaneously, and the relevant parameters of each curve are automatically calculated to diagnose the deformation of the winding and provide reference conclusions for diagnosis.


The software management function is powerful, fully considering the needs of on-site use. The measurement data is automatically saved and exported to generate Word version test reports (with corresponding Office software installed) or JPG image reports, making it convenient for users to generate test reports.


The software has obvious humanization characteristics, with various measurement conditions being optional and not requiring a lot of input on site, making it more convenient to use.


The software has a high degree of intelligence, and after the input and output signals are connected, all measurement work can be completed with just one key press.


The software interface is simple, intuitive, and practical.