Maintenance Method for Jet Aeration Machine/QSB2.2 Jet Submersible Aeration Machine
Maintenance and troubleshooting methods for jet aerators
Submersible jet aerator
QSB jet aerator
1. Cleaning
To prevent impurities from accumulating inside the submersible aerator at different times, clean water can be pumped from the submersible aerator to clean it. If the submersible aerator is not used for a long time, it should be placed in a dry place and pay attention to antifreeze.
2. Oil injection and oil change
Nanjing Du'anThe oil chamber of the submersible aerator has been injected with an appropriate amount of lubricating oil before leaving the factory. This oil should be replaced annually. The oil change should be carried out according to the following method: place the submersible aerator with the oil chamber plug facing downwards, loosen the plug, release the lubricating oil, then clean the oil chamber with washing oil, inject an appropriate amount of lubricating oil, and replace it with a new oneO-ring, tighten the screw plug. If water is found in the oil, flush the oil chamber according to regulations, refill it with oil, and tighten the screw plug with O-ring. Three weeks later, it must be rechecked. If the oil turns into an emulsion again, the mechanical seals should be inspected. If necessary, it should be replaced (please contact our maintenance department).
pourThe oil is transformer oil.
3. Operational malfunction
In case of a malfunction during operation, if the cause cannot be determined and the troubleshooting methods provided later still cannot solve the problem, temporary methods should not be used, and unauthorized repairs and dismantling should not be carried out. Contact our Nanjing Du'an Water Treatment After sales Service Department immediately.
Troubleshooting method for jet type submersible aerator
Fault phenomenon |
cause analysis |
Nanjing Du'an Water TreatmentTroubleshooting |
power equipment |
1. The inlet pool does not meet the requirements |
1. Improve water inlet conditions 00001. Check the wear of the blades and readjust the installation
dress |
Decreased aeration rate |
1. The diving depth of the submersible aerator is too deep |
1. Improve the submersible aerator |
Running with impurities |
1. The foundation of the submersible aerator device is not strong enough |
1. Strengthen the foundation and tighten the screws |
Diving aeration |
1. Winding, connector or cable open circuit |
1. Check with an ohmmeter |
Diving aeration |
1. Low voltage |
1. Not currently in use or due to excessively long wiring |
Any adjustment of the equipment must be approved by our company!