Product Overview:
Add a known amount of potassium dichromate solution and mercury solution to the water sample, and use silver as a catalyst in a strong acid medium. After boiling and refluxing for 2 hours, use 1, 10Using ortho phenanthroline as an indicator, titrate unreduced potassium dichromate in water samples with ammonium ferrous sulfate, converted from the amount of consumed ammonium ferrous sulfateThe mass concentration of oxygen consumption is the apparent COD. Export the gas formed by the oxidized chloride ions in the water sample that have not been complexed, and then use hydrogen
After absorption of sodium oxide solution, potassium iodide is added and the pH is adjusted to about 3-2. Starch is used as an indicator and titrated with standard sodium thiosulfate titration solutionThe amount of sodium thiosulfate converted to the mass concentration of oxygen consumed is the chloride ion correction value. The difference between the apparent COD and chloride ion correction values is the measured water sampleThe real COD.
Technical parameters:
Number of measured samples: 6 samples
Measurement range: 0-700mg/L, 0-7000mg/L (diluted water sample), chloride ion less than 20000mg/L;
Measurement time: no more than 2 hours
Measurement error: Potassium hydrogen phthalate standard solution (500mg/L), relative standard deviation not exceeding 5.0%
Industrial organic wastewater (500mg/L), with a relative standard deviation not exceeding 8.0%
Environmental temperature: 5-40 ℃
Heating power: 1300W (AC 220V ± 22V, 50HZ)
Cooling method: air-cooled, fan power greater than 80W
Flow range: 0-60ml
Application scope:
This method is applicable for the determination of chemical oxygen demand (COD) in high chloride wastewater with chloride ion content less than 20000mg/L. The detection limit of the method is 30mg/L. Suitable for the determination of COD in wastewater such as oil fields, coastal refineries, oil depots, chlor alkali plants, and deep-sea wastewater discharge.
The instrument adopts a glass burr reflux tube instead of a spherical reflux tube, and uses air cooling technology instead of tap water cooling, which can save water and make the instrument more efficient
Standardization, while making instrument use more reassuring. The instrument is also equipped with an air pressure sampling device and an automatic zeroing burette, which simplifies the titration operation procedures in the later stage,
Improved the reliability of the method.
Advantages of the instrument:
The front panel of the instrument is made of stainless steel plate material, and the electric furnace plate is made of microcrystalline glass. The electric furnace wires below are spiral shaped and heated separately for uniform heating. And like
If corrosive acids and alkalis drip onto the circuit board, simply wipe it clean. If corrosive acids and bases drip onto the ordinary electric furnace plate
Corrosion of the electric furnace wire causes a short circuit in the electric furnace plate.