Measurement diameter: DN001~DN150 Measurement accuracy: L: ± 0.5% M: ± 0.2% H: ± 0.15% Pressure rating: L: 4MPaM:10MPaH:34.5MPaO: Other fluid temperat
Product details

Measuring diameter: DN001~DN150


Measurement accuracy:

L:±0. 5%

M:±0.2%

H:±0.15%


Pressure level:

L: 4MPa

M:10MPa

H:34.5MPa

O: other


Fluid temperature:

S:-50℃~+180℃;

H: -50 ℃ to+350 ℃.


Protection level:

1: IP65

2: IP67

3: IP68


Power supply:

1:85~240V AC,50/60Hz

2:18~36V DC,8W

0: Adaptive power supply


Output method:

1: Analog output+pulse output

2: Analog output+pulse output+HART protocol

3: Analog output+pulse output+RS485

0: Customized according to customer requirements


Product CategoryrangeError (%) Zero stability (kg/h) Contact material

MG00110(kg/h)±0.15/±0.20.005316l stainless steel

MG003260(kg/h)±0.15/±0.20.013316l stainless steel

MG0081800(kg/h)±0.15/±0.20.090316l stainless steel

MG0152200(kg/h)±0.15/±0.20.110316l stainless steel

MG0256000(kg/h)±0.15/±0.20.300316l stainless steel

MG05035000(kg/h)±0.15/±0.21.750316l stainless steel

MG08090000(kg/h)±0.15/±0.24.500316l stainless steel

MG100110000(kg/h)±0.15/±0.25.500316l stainless steel

MG150635000(kg/h)±0.15/±0.231.750316l stainless steel


Work environment:

Atmospheric pressure: 86kPa~106kPa

Environmental temperature:- 40℃~ +85℃;

Relative humidity: 35%~95%

Power supply voltage: DC 18V~36V 8W

power waste:

Power ≤ 15W

communication interface

4-20mA current loop (error ≤± 0.005mA), pulse 0-10KHz HART、RS485。


MG9900 series quality flowmeter

Coriolis force mass flowmeter

When the range ratio is 25:1, the error can reach ± 0.15% of the displayed value, and the highest instrument range ratio is 100:1;


Based on advanced digital signal processing technology in the frequency domain, it solves problems such as time drift and temperature drift

High precision real-time calculation of medium quality flow rate and density;


Utilizing patented coupling vibration isolation technology, the product is insensitive to on-site vibration interference and has strong adaptability;


Equipped with an integrated transmitter, easy to install, no straight pipe requirements, whether upstream or downstream of the sensor

Downstream, fully compatible with similar foreign products.


Widely used for pressure testing of pipelines and equipment in the petroleum, chemical, mining, machinery, power, and food industries.