Measurement parameters: liquid level, interface
Medium density: Liquid level 450-1350Kg/m ³ Boundary: 120-890Kg/m ³
Electrical interface: 1/2 "NPT or M20 × 1.5
Input voltage: 13.5-30VDC
Protection against polarity misconnection
Process pressure: 0~2.5bar(0~2.5MPa)
Bundled 0-420 bar
(0~420MPa)
Process temperature: -320 to 1000 ℉ (-196 to 538 ℃)
Output signal: 2-wire 4-20mADC HART
Measurement accuracy: ±0.01%
Process display: 4-20mA, percentage, engineering unit
Probe length: Outer diameter 5/8 "(15.9mm)
35"~236"(900~6000mm)
Process connection: flange connection or threaded connection
texture of material: 316LSST, 304SST, titanium, tantalum
304LSST, PTFE lined anti-corrosion, etc
Explosion proof mark: intrinsic safety Ex ia Ⅱ C T1 ~ T6
Explosion proof Ex d Ⅱ C T1 ~ T5 Gb
Protection level: IP67
MG8801 Top mounted Magnetostrictive Transmitter
MG8802 side mounted bundled magnetostrictive transmitter
MG8803 float transmitter
MG8804 Top mounted Binding Magnetostrictive Transmitter
MG8805 dual cavity bundled magnetostrictive transmitter
The starting pulse generated by the circuit module is transmitted along the waveguide and generates a return pulse with the floating ball magnetic field. The circuit module calculates the time difference between the starting pulse and the return pulse. As the floating ball changes synchronously with the liquid level, the liquid level height can be accurately measured.
Measuring liquid level and interface, integrating remote transmission and local indication, simple calibration, key calibration once, no need for repeated calibration;
Replace the module, automatically read and store data, no calibration required;
Dual chamber explosion-proof isolation, safe and convenient operation;
The liquid receiving components are made of all stainless steel and polytetrafluoroethylene materials, which are resistant to corrosive media such as strong acids and alkalis;
The core components are non-contact with the medium and do not require regular maintenance.
Measurement of liquid levels and interfaces in strong acid and alkali media, mixed liquids, emulsion layer liquids, high-temperature and high-pressure liquids, negative pressure working condition liquids, and low-density liquids.