Measurement parameters: liquid level, material level
Installation methods: top mounted, side mounted
Damping: 2 seconds
Electrical interface: 3/4"NPT
Input voltage: 24VDC or 220VAC, with polarity reversal protection
Process pressure: 0~63bar(0~6.3MPa)
Process temperature: -40~842 ℉ (-40~450 ℃)
Output signal: Relay group two normally open and normally closed; The output of the contact switch (contact capacity 220VAC 5A 24VDC 5A) is normally 8mA for the two-wire system, 16mA alarm current switch output
Measurement accuracy: ±2mm
Process display: LED red/blue indicator
Probe length: 9"~118"(100~3000mm)
Process connection: flange connection or threaded connection
texture of material: 316LSST, 304SST, titanium, etc
Explosion proof mark: intrinsic safety Ex ia Ⅱ C T1 ~ T6
Explosion proof Ex d Ⅱ C T1 ~ T5 Gb
Protection level: IP67
MG8400 ordinary tuning fork level controller
MG8430 Extended Tuning Fork Level Controller
The circuit drives the piezoelectric crystal to resonate with the tuning fork body. When the material is immersed in the tuning fork body, the vibration frequency changes. The circuit module detects this signal and amplifies it to drive the relay output switch contact signal.
Reliable solution to the impact of hanging materials and scaling measurement accuracy;
● Clear on-site indication of LED red/blue;
Module design and movable parts without disassembly or wear, with a long service life.
DC and AC are optional, with convenient and versatile applications.
Level control of liquid, mixed media, slurry, powder, and particles.