Measurement parameters: liquid level, interface
Installation methods: top mounted, side mounted
Medium density: liquid level 450-1350Kg/m ³; Interface difference of 120-890Kg/m ³
Electrical interface: 1/2 "NPT or M20 × 1.5
Input voltage: 13.5-30VDC, with polarity reversal protection
Process pressure: 0~63bar(0~6.3MPa)
Bundled 0-420 bar (0-420 MPa)
Process temperature: -40~248 ℉ (-40~120 ℃)
Bundled -40~842 ℉ (-40~450 ℃)
Output signal: 2-wire 4-20mADC HART
Measurement accuracy: ±0.5%
Process display: 4-20mA, percentage, engineering unit
Probe length: Outer diameter 5/8 "(15.9mm), 35" to 236 "(900 to 6000mm)
texture of material: 316LSST, 304SST, titanium, 304LSST, tantalum, PTFE lined anti-corrosion, etc
Process connection: flange connection or threaded connection
Explosion proof mark: intrinsic safety Ex ia Ⅱ C T1 ~ T6
Explosion proof Ex d Ⅱ C T1 ~ T5 Gb
Protection level: IP67
MG8351 ordinary magnetic float level transmitter
MG8352 Intelligent Magnetic Float Liquid Level Transmitter
The reed switch inside the probe rod is coupled by the external magnetic field of the float and sequentially connected in series with resistors. The circuit module converts the resistance change into a 4-20mA signal. Since the float changes synchronously with the liquid level, the liquid level position can be measured.
Measuring liquid level and interface, integrating remote transmission and local indication; Easy to calibrate, press the button to calibrate once without the need for repeated calibration;
Replace the circuit module, automatically read and store data, no calibration required;
The liquid receiving components are made of all stainless steel and polytetrafluoroethylene materials, which are resistant to corrosive media such as strong acid and alkali.
Measurement of liquid level and interface of acid, alkali, and mixed liquids.