MES5 turbidity electrode
Sludge interface/sludge concentration/turbidity electrode MES5 French PONSEL $n optical sensor based on absorption measurement principle$ Measurement
Product details

Turbidity electrode MES5

1、 Characteristics

Optical sensor based on absorption measurement principle.

Measurement range: SS:0-50 g/LTurbidity: 0-4000 FAUsludgeInterface 0-100%.

digital communication interface: RS485Modbus protocol.

More robust sensors.

1Optics

Digital sensors2 optional models

MES5: Can measure suspended solids concentration (SS), turbidity, and sludge interface.

VB5: Individual measurementSludge interface.

2Testing PrinciplesIn the test liquid,The wavelength is870 After passing through a 5mm optical path, the attenuation degree of nm infrared light is calculated, and the sensor converts the signal attenuation amount into SS (unit: g)/L)Turbidity (in units of FAU) and sludge layer thickness (in units of% transmittance) are displayed. The testing process will undergo temperature correction to achieve maximum accuracy.

3SS directly awaiting sludge calibration for testing.

turbidity04000 FAU)ToFormazine solution calibration.

Temperature testing and calibration are carried out through thermistors.

4digital communication/Integrated transmitter

PONSEL sensors can be connected to any type of recorder, transmitter, remote processing system, or automatic controller through an RS485 digital interface. Due to the use of digital technology, over 200 sensors can be connected to the same recorder.

5sensorBuilt in signal preprocessing deviceThe processed signal runs completely digitallyThis will greatly improve the anti-interference ability of the probe.

6Data and calibration are closely linkedAndAll calibration history and operational information can be digitizedRecord the MES5 sensor.

7Physical characteristics:

The polyoxymethylene resin material ensures excellent mechanical strength of the sensor and good sealing effect of the cable.Because of sensor integrationstronglightIts characteristics can be easily adapted for portable use or fixed installation.

2、 Application scope

wastewater treatment plant(Water inlet)- SS or turbidityAeration tank - SSWater outlet - turbidity

Industrial wastewater treatment plant(Aeration tank)—SSClarifying tank sludge interfaceWater outlet - turbidity

Sludge Treatment Plant(Sludge concentration tank)

Dredging site(Turbidity)

IIITurbidity electrode MES5Technical Parameter

SS measurement

measuring principle

Infrared absorption principle (wavelength 870nm)

measuring range

SS:0-50 g/L

turbidity: 04000 FAU

sludgeInterface: 0-100 %transmissivity

resolution

SS:0.01g/L

turbidity: 0.01-1 FAU

sludgeInterface: 0.01%-0.1%transmissivity

accuracy

SS:<10%;

turbidity± 5% (with a range of 200)-At 4000 FAU);

sludgeInterface: ±2%

reaction time

< 35s

temperature measurement

measuring principle

NTC Thermistor Method

measuring range

-5.00—60.00

resolution

0.01

accuracy

±0.5

storage temperature

-1060

protection grade

IP68

communication interface

ModbusRS485 orSDI-12

Data update time

<1s

power supply

5-28 V

Power consumption

Standby mode: 25 μA(5V);

RS485 signal (once per second):4.5 mA(5V);

SDI-12Signal (once per second):4.5 mA(5V);

pulse signal: 100 mA(within 30ms);

heating time: 100 mS

sensor

weight

750 g (Sensor only)

material

Polyoxymethylene resin

Voltage endurance range

5 Bar

Cable/Connection

9-pin protective connector, polyurethane sheath, bare wire, or waterproof Fisher connector