Liquid level display, controller
Liquid level display product overview: MS-XMTA-9000 liquid level display and controller series products, (intelligent digital (light column) display r
Product details

Overview of Liquid Level Display Products:
The MS-XMTA-9000 liquid level display and controller series products (intelligent digital (light column) display regulator) can output up to 5 switch values, including one dedicated to controlling the input part's resistance, coupling, and open circuit information, and another for switch values, control values, or programmable dual timers, counters, or programmable intelligent sound and light alarms. The PID continuous control variable in the instrument outputs process variables, setpoint values, valve position feedback, etc. in the form of 0-10mA or 4-20mA analog signals. The same quantity can give any one or two outputs
Up to three ports can be used, and in case of unforeseeable faults in the input part, the relays and analog output parts used for positional control can maintain their pre fault state. The instrument display is flashing. In the event of a fault, the output of the instrument's intermittent and continuous PID control remains at its pre fault level in automatic mode. The regulator pauses the operation. The operator can still control it manually.
Universal signal input, users can choose freely. (Thermocouple, Thermistor, Voltage, Current, Linear Resistance, Frequency). The measured values and set values can be displayed using analog bars or digital screens, and the display content can be freely switched.
The measured value and the set value can be added or subtracted.
8 alarm control modes to choose from.
Square opening and small signal resection can be performed.
The switch mode power supply instrument can have 5 switch outputs, one for the disconnection alarm of the input part, and the other 4 for positional control.
When there are faults such as broken resistance, broken coupling, or broken wire, the alarm relay can select the output state.
It can be used as a counter and reversible counter instrument. After power failure, it can restore the count value before power failure by re powering on. It can clear the count value, preset the number, and provide upper and lower limit alarms and transmission outputs for the count value.
Can achieve associated alarm control mode.
External 24V, 30mA or 50mA or 100mA power supply (can be used as a two-wire transmitter power supply).
Measurement value or internal given value transmission output: 0-10mA, 4-20mA, 0-5V, 1-5V, 0-10V.
We can provide asynchronous serial communication methods for RS485, including multi host, single host, and no host modes. Communication data verification follows the CRC-16 American data communication standard, with high reliability cycling and barcode verification.