Brand of large alternating humidity and heat test room in research institutes
controller |
Imported microcomputer temperature and humidity integrated controller (temperature directly displays percentage) |
Accuracy range |
Setting accuracy: temperature ± 0.1 ℃, humidity ± 0.1% RH |
Temperature and humidity sensor |
Platinum resistance? PT100Ω |
heating system |
Completely independent system, nickel chromium alloy electric heating heater |
Humidification system |
External isolation type, all stainless steel boiler type shallow surface evaporative humidifier |
Dehumidification system |
Adopting evaporator coil dew point temperature laminar contact humidifier |
Water supply system |
The humidification water supply adopts automatic control and can recycle residual water, saving water and reducing consumption |
refrigeration system |
Original "Taikang"/fully enclosed air-cooled double selection compression refrigeration method |
circulatory system |
Temperature resistant and low-noise air conditioning motor, multi blade centrifugal fan |
Studio Standard Cube: 0.5, 1.0, 2,... 25, 30, 40 cubic meters (cubic meter) Upper Temperature Limit: 100℃ Lower Temperature Limit: -70℃ Temperature Deviation: ±2℃ Temperature fluctuations: ±0.5℃ Humidity Range: 30-98%R.H Humidity error: +2/-3%R.H Heating Time: Average 1 ℃/min Cooling Time: Average 1 ℃/min Cooling method: Water cooling Controller: Chinese LCD touch screen temperature controller, PID control algorithm Chinese LCD screen temperature controller, PID control algorithm User program capacity Formula Capacity: 120 groups, 1200 sections Security protection measures: Temperature upper limit control, compressor overpressure, compressor overload, heater short circuit temperature control, compressor supervoltage, compressor overload , heater short circuit Power Supply: 380V, 50Hz, Three phase four wire Material: SUS#304 Function: Program control temperature and humidity
The reference standards are: GB/T2423.1-2008 Test A Low Temperature Test Method, GB/T2423.2-2008 Test B High Temperature Test Method, GB/T2423.3-2006 Test Ca Constant Damp Heat Test Method, GB/T2423.4-2008 Test Db Alternating Damp Heat Test Method
Laboratory decoration: strict insulation and moisture insulation performance is required. It is recommended to use color steel composite panels for the four facades of the laboratory, and PE insulation panels for insulation and moisture insulation treatment for the top and bottom surfaces; For perspective windows, it is required to use double-layer vacuum glass windows.

The controller operation interface is available in both Chinese and English, and the real-time operation curve chart can be displayed on the screen.
It has a capacity of 120 sets of programs, 12000 segments, and 999 loop steps, with a maximum time setting of 99 hours and 59 minutes per segment.
After inputting the data and experimental conditions, the controller has a screen lock function to avoid manual touch and shutdown.
It has the function of automatic calculation, which can immediately correct the temperature and humidity change conditions, making temperature and humidity control more accurate and stable.
Freezing and air circulation system.
The refrigeration unit adopts the original French "Taikang" fully enclosed compressor.
The refrigeration system adopts a unit or binary low-temperature circuit system design.
Adopting a multi wing air supply fan for strong air circulation, avoiding any dead corners, can make the temperature and humidity distribution in the testing area uniform.