Laboratory BOD analyzer
The laboratory BOD analyzer has achieved mercury free BOD determination, with simple operation, accurate testing, automatic saving of 5-day measuremen
Product details
The laboratory BOD analyzer has achieved mercury free BOD determination, with simple operation, accurate testing, automatic saving of 5-day measurement values, and expandable functions. The testing principle of laboratory BOD analyzer is pressure probe sensing method

Laboratory BOD analyzers OxiTop IS 6 and OxiTop IS 12
Mercury free pressure sensing method
◆ 5-day automatic reading
Range 0-4000mg/l, reserved for 5000mg/l
◆ Automatically record daily BOD values
The testing method complies with DIN 38409 part 52, does not contain mercury, and is non polluting
◆ Automatic temperature monitoring, automatic zeroing
◆ Automatic constant speed mixing
◆ Certified by CE, TUV/GS, UL, CU

Laboratory BOD analyzers OxiTop IS 6 and OxiTop IS 12
Mercury free BOD testing
Although we are still exploring alternative methods for rapid determination of BOD, the importance of BOD testing has not diminished as a result
On the contrary, it is still one of the important indicators for evaluating the quality of water resources, and it reflects the biodegradable substances in water
How much is it. Traditional stress testing has been criticized for using mercury, which is a toxic substance known for its vapor
Endangering human health. Therefore, the OxiTop pressure measurement system developed by WTW company meets the requirements of a wide range of customers,
To achieve mercury free BOD determination. With OxiTop, WTW can provide customers with a brand new mercury free laboratory BOD analyzer, which is very suitable for
At the same time, OxiTop revolutionizes the previously cumbersome process for daily BOD testing.


advantage:
Easy to operate, button based operation
Mercury free determination, accurate and reliable testing
Automatic saving of 5-day measurement values
Scalable functionality
Easy to move


Laboratory BOD analyzers OxiTop IS 6 and OxiTop IS 12
OxiTop patented sensing components include:
1. 1 piezoelectric sensor
2. 2 buttons, M displays the current value, S displays the saved value
3. Two LEDs display 00... 50, with each unit representing 3.55hPa. Normal values are less than 40, and larger displays are allowed for specific purposes
The numerical value
3. It can save 5 sets of data, one set per day, without the need to read every day, as the instrument will save the measured values for that day. This means
You can start testing on weekends without the need for dedicated supervision, and you can also check the test results (BOD7) after 7 days
4. AutoTemp automatic temperature compensation, when the sample temperature is too low, the instrument will delay the measurement until the temperature stabilizes at a certain value.
The longest delay time can reach 3.5 hours, and the shortest is 0.5 hours
5. 2 batteries, with a normal lifespan of up to 1 year