LUX-100S Spiral Vortex Flow Meter
LUX-100S Vortex Flow Meter I. Overview of LUX-100S Vortex Flow Meter When a fluid flowing along the axial direction enters the inlet of the LUX-100S v
Product details
LUX-100S Spiral Vortex Flow Meter

When the fluid flowing along the axial direction enters the inlet of the LUX-100S vortex flowmeter, the vortex generator forces the fluid to undergo rotational motion, resulting in a vortex flow at the center of the vortex generator. The vortex flow spirals in the Venturi tube and reaches the contraction section, where it suddenly throttles to accelerate the vortex. When the vortex enters the diffusion section, it is forced to undergo a spiral type secondary rotation due to the backflow effect. At this point, the rotational frequency of the vortex flow is proportional to the velocity of the medium and is linear. The weak charge signals detected by two piezoelectric sensors are differentially amplified, filtered, and shaped by a preamplifier into two pulse signals with frequencies proportional to the flow rate. At the same time, the processing circuit compares and distinguishes the phase of the two pulse signals, removes interference signals, and counts and processes the normal flow signal.
2、 Characteristics of LUX-100S Spiral Vortex Flow Meter
1. By adopting unique dual sensor technology and circuit processing technology, the interference of pressure fluctuations and mechanical vibrations on this type of flowmeter is effectively solved, and the measurement is accurate and reliable.
2. No mechanical movable parts, high reliability, good stability, and low maintenance volume.
3. Adopting low-power high-tech, it can work with both internal and external power sources, and the internal battery can be used continuously for more than three years.
4. LCD displays instantaneous flow rate and cumulative flow rate of operating conditions, with clear and intuitive display and convenient reading.
5. Equipped with working condition pulse signal, 4-20mA standard current signal output, and RS485 communication interface for users to choose from.
5. Instantaneous flow and cumulative total can be transmitted from the site through RS485 interface.
6. Easy to install.
3、 Main technical parameters of LUX-100S spiral vortex flowmeter
Model specifications | Nominal Diameter (mm) |
Flow range (m3/h) |
pressure rating (MPa) |
accuracy (Level) |
At Qmax Pressure loss (kPa) |
Shell Material |
LUX-20S | 20 | 1.2~15 | 1.6; 2.5; 4.0; 6.3; 10; 16 |
1.0 1.5 |
3.30 | ≤ 2.5MPa, aluminum alloy; ≥ 4.0MPa, stainless steel |
LUX-25S | 25 | 2.5~30 | 2.10 | |||
LUX-32S | 32 | 4.5~60 | 2.90 | |||
LUX-50S | 50 | 10~150 | 3.90 | |||
LUX-80S | 80 | 28~400 | 1.6; 2.5; 4.0; 6.3; ten |
3.70 | 1.6MPa, aluminum alloy; ≥ 2.5MPa, stainless steel |
|
LUX-100S | 100 | 50~800 | 5.90 | |||
LUX-150S | 150 | 150~2250 | 1.6; 2.5; four | 11.00 | ||
LUX-200S | 200 | 360~3600 | 16.00 |